Tài liệu tham khảo
Svensson, 2013
JT/T 775-2016. Cable of parallel steel wires for large-span cable-stayed bridge. Beijing: China Communications Press, 2016 (in Chinese).
Casciati, 2003, An overview of structural health monitoring expertise within the European Union, Struct. Health Monit. Intell. Infrastruct., 31
J. Ou, The state-of-the-art and application of intelligent health monitoring systems for civil infrastructures in mainland of China, Prog. Struct. Eng. Mech. Comput. (2004) 599–608.
Yang, 2018, State-of-the-art review on modal identification and damage detection of bridges by moving test vehicles, Int. J. Struct. Stab. Dyn., 18, 1850025, 10.1142/S0219455418500256
Zarbaf, 2018
Mehrabi, 2006, In-service evaluation of cable-stayed bridges, overview of available methods and findings, J. Bridge Eng., 11, 716, 10.1061/(ASCE)1084-0702(2006)11:6(716)
Liu, 2018, A review of cable force testing, Henan Build. Mater., 02, 241
Levien, 2008
D.U. Guohua et al., Structural Analysis in the Bridge, Tongji University Press, Shanghai, 1994, pp. 222–224 (in Chinese).
Zui, 1996, Practical formulas for estimation of cable tension by vibration method, J. Struct. Eng., 122, 651, 10.1061/(ASCE)0733-9445(1996)122:6(651)
Jiangbo Sun, Frequency Vibration Based Cable Tension Force Measurement for Cable-Stayed Bridges, Beijing Forestry University, 2012 (in Chinese).
Sun, 2011, Measuring methods of cable tension in cable-stayed bridges, vol. 295, 1230
Zalt, 2007, Evaluating sensors for bridge health monitoring, 368
Bergamini, 2001, Nondestructive testing of stay cables, vol. 84, no. 2, 16
McGogney, 1995, Magnetic flux leakage for bridge inspection, Nondestruct. Testing Methods Civ. Infrastruct., 31, 10.1061/9780784401316.003
Duan, 2016, Development of elasto-magneto-electric (EME) sensor for in-service cable force monitoring, Int. J. Struct. Stab. Dyn., 16, 1640016, 10.1142/S0219455416400162
Cho, 2013, Comparative field study of cable tension measurement for a cable-stayed bridge, J. Bridge Eng., 18, 748, 10.1061/(ASCE)BE.1943-5592.0000421
Sumitro, 2002, Elasto-magnetic sensor utilization on steel cable stress measurement, 13
Mehrabi, 2010, Evaluation, rehabilitation planning, and stay-cable replacement design for the hale boggs bridge in Luling, Louisiana, J. Bridge Eng., 15, 364, 10.1061/(ASCE)BE.1943-5592.0000061
Fang, 2012, Practical formula for cable tension estimation by vibration method, J. Bridge Eng., 17, 161, 10.1061/(ASCE)BE.1943-5592.0000200
Øiseth, 2015, Monitoring wind velocities and dynamic response of the Hardanger Bridge, 117
Grosse, 2008
Zejli, 2012, Detection of the presence of broken wires in cables by acoustic emission inspection, J. Bridge Eng., 17, 921, 10.1061/(ASCE)BE.1943-5592.0000404
Li, 2012, Acoustic emission technique for monitoring stay cable fatigue damage evolution of multi-aged bridge, J. Vib. Shock, 31, 67
Sabri, 2015, Fiber optic sensors: short review and applications, 299
Scarella, 2017, Dynamic brillouin scattering–based condition assessment of cables in cable-stayed bridges, J. Bridge Eng., 22, 04016130, 10.1061/(ASCE)BE.1943-5592.0001010
Zhao, 2017, Smartphone-based mobile testing technique for quick bridge cable–force measurement, J. Bridge Eng., 22, 06016012, 10.1061/(ASCE)BE.1943-5592.0001011
Morgenthal, 2018, Determination of stay-cable forces using highly mobile vibration measurement devices, J. Bridge Eng., 23, 04017136, 10.1061/(ASCE)BE.1943-5592.0001166
Michie, 1994, Machine learning, Neural Statist. Classif., 1994, 1
Sun, 2020, Review of bridge structural health monitoring aided by big data and artificial intelligence: from condition assessment to damage detection, J. Struct. Eng., 146, 04020073, 10.1061/(ASCE)ST.1943-541X.0002535
Pan, 2018, Time-frequency-based data-driven structural diagnosis and damage detection for cable-stayed bridges, J. Bridge Eng., 23, 04018033, 10.1061/(ASCE)BE.1943-5592.0001199