Research on the Method of Predicting Corrosion width of Cables Based on the Spontaneous Magnetic Flux Leakage
Tóm tắt
The detection of cable corrosion is of great significance to the evaluation of cable safety performance. Based on the principle of spontaneous magnetic flux leakage (SMFL), a new method for predicting the corrosion width of cables is proposed. In this paper, in order to quantify the width of corrosion, the parameter about intersecting point distance between curves of magnetic flux component of x direction at different lift off heights (Dx) is proposed by establishing the theoretical model of the magnetic dipole of the rectangular corrosion defect. The MATLAB software was used to analyze the influencing factors of Dx. The results indicate that there exists an obvious linear relationship between the Dx and the y (lift off height), and the Dx–y curves converge to near the true corrosion width when y = 0. The 1/4 and 3/4 quantiles of the Dx–y image were used for linear fitting, which the intercept of the fitting equation was used to represent the predicted corrosion width. After the experimental study on the corrosion width detection for the parallel steel wire and steel strand, it is found that this method can effectively improve the detection accuracy, which plays an important role in cable safety assessment.
Từ khóa
Tài liệu tham khảo
Du, 2018, Mechanical properties of high tensile steel cables at elevated temperatures, Constr. Build. Mater., 182, 52, 10.1016/j.conbuildmat.2018.06.012
Ho, 2013, An efficient image-based damage detection for cable surface in cable-stayed bridges, NDT E Int., 58, 18, 10.1016/j.ndteint.2013.04.006
Capozzoli, 2017, Combined NDT Techniques in Civil Engineering Applications: Laboratory and the Real Test, Constr. Build. Mater., 154, 1139, 10.1016/j.conbuildmat.2017.07.147
Gou, 2011, Residual stress measurement of new and in-service x70 pipelines by x-ray diffraction method, NDT E Int., 44, 387, 10.1016/j.ndteint.2011.03.003
Kim, 2010, Ability of acoustic emission technique for detection and monitoring of crevice corrosion on 304l austenitic stainless steel, NDT E Int., 36, 553, 10.1016/S0963-8695(03)00065-3
Patil, 2014, Acoustic emission vis-à-vis electrochemical techniques for corrosion monitoring of reinforced concrete element, Constr. Build. Mater., 68, 326, 10.1016/j.conbuildmat.2014.06.068
Elfergani, 2013, Damage assessment of corrosion in prestressed concrete by acoustic emission, Constr. Build. Mater., 40, 925, 10.1016/j.conbuildmat.2012.11.071
Tao, 2018, Crack detection algorithm for fluorescent magnetic particle inspection based on shape and texture features, J. Tsinghua Univ. (Sci. Technol.), 58, 50
Shi, Z., Xu, X., Ma, J., Zhen, D., and Zhang, H. (2018). Quantitative detection of cracks in steel using eddy current pulsed thermography. Sensors, 18.
Rifai, D., Abdalla, A.N., Razali, R., Ali, K., and Faraj, M.A. (2017). An eddy current testing platform system for pipe defect inspection based on an optimized eddy current technique probe design. Sensors, 17.
Gao, 2017, Quantitative validation of eddy current stimulated thermal features on surface crack, NDT E Int., 85, 1, 10.1016/j.ndteint.2016.09.002
Wu, 2017, Composite Magnetic Flux Leakage Detection Method for Pipelines Using Alternating Magnetic Field Excitation, NDT E Int., 91, 148, 10.1016/j.ndteint.2017.07.002
Kim, 2018, Magnetic flux leakage sensing and artificial neural network pattern recognition-based automated damage detection and quantification for wire rope non-destructive evaluation, Sensors, 18, 109, 10.3390/s18010109
Tsukada, K., Majima, Y., Nakamura, Y., Yasugi, T., Song, N., and Sakai, K. (2017). Detection of inner cracks in thick steel plates using unsaturated ac magnetic flux leakage testing with a magnetic resistance gradiometer. IEEE Trans. Magn., 53.
Huang, 2017, Characterizing the Magnetic Memory Signals on The Surface of Plasma Transferred Arc Cladding Coating Under Fatigue Loads, J. Magn. Mater., 443, 281, 10.1016/j.jmmm.2017.07.067
Hong, 2016, The non-destructive test of steel corrosion in reinforced concrete bridges using a micro-magnetic sensor, Sensors, 16, 1439, 10.3390/s16091439
Runchuan, 2018, Quantitative study on corrosion of steel strands based on self-magnetic flux leakage, Sensors, 18, 1396, 10.3390/s18051396
Grinzato, 2007, Hidden corrosion detection in thick metallic components by transient ir thermography, Infrared Phys. Technol., 49, 234, 10.1016/j.infrared.2006.06.011
Zhang, 2015, Corrosion detection for steel wires in bridge cables using magnetic method, IABSE Symp. Rep., 104, 1
Bacchelli, 2010, Corrosion detection in a 2d domain with a polygonal boundary, J. Inverse ILL-Posed Probl., 18, 281, 10.1515/jiip.2010.011
Han, 2004, Detection of corrosion steel under an organic coating by infrared photography, Corros. Sci., 46, 787, 10.1016/j.corsci.2003.12.001
Caleyo, 2015, Bayesian analysis of external corrosion data of non-piggable underground pipelines, Corros. Sci., 90, 33, 10.1016/j.corsci.2014.09.012
Satyarnarayan, 2008, Circumferential higher order guided wave modes for the detection and sizing of cracks and pinholes in pipe support regions, NDT E Int., 41, 32, 10.1016/j.ndteint.2007.07.004
Snarskii, 2010, An integral equation model for the magnetic flux leakage method, NDT E Int., 43, 343, 10.1016/j.ndteint.2010.01.008