Cable Force Health Monitoring of Tongwamen Bridge Based on Fiber Bragg Grating
Tóm tắt
Từ khóa
Tài liệu tham khảo
Chan, 2006, Fiber Bragg grating sensors for structural health monitoring of Ting Ma bridge: Background and experimental, Eng. Struct., 28, 648, 10.1016/j.engstruct.2005.09.018
Richard, 2013, Commissioning and evaluation of a fiber-optic sensor system for bridge monitoring, IEEE Sens. J., 13, 2555, 10.1109/JSEN.2013.2256599
Guo, 2016, Design and Investigation of a Reusable Surface-Mounted Optical Fiber Bragg Grating Strain Sensor, IEEE Sens. J., 16, 8456
Wang, 2013, Fiber grating acceleration vibration sensor with double uniform strength cantilever beams, J. Optoelectron. Laser, 24, 635
Yang, 2014, Magnetic field sensing based on tilted fiber Bragg grating coated with nanoparticle magnetic fluid, Appl. Phys. Lett., 104, 061903, 10.1063/1.4864649
Tong, 2013, Simultaneous measurement of refractive index, temperature and strain based on core diameter mismatch and polarization maintaining FBG, Optoelectron. Lett., 9, 238, 10.1007/s11801-013-2403-1
Mousumi, 2008, Fiber Bragg gratings in structural health monitoring-Present status and applications, Sens. Actuators A Phys., 147, 150, 10.1016/j.sna.2008.04.008
Minardo, 2013, Real-time monitoring of railway traffic using slope-assisted Brillouin distributed sensors, Appl. Opt., 52, 3770, 10.1364/AO.52.003770
Li, 2011, Development and sensing properties study of FRP-FBG smart stay cable for bridge health monitoring applications, Measurement, 44, 722, 10.1016/j.measurement.2011.01.005
Grattan, 2009, Monitoring of corrosion in situ in structural reinforcements bars using a wrapped fiber optic sensor network, Sens. Actuators A Phys., 1, 1
Loutas, 2012, Intelligent health monitoring of aerospace composite structures based on dynamic strain measurements, Expert Syst. Appl., 39, 8412, 10.1016/j.eswa.2012.01.179
Panopoulou, 2012, Dynamic fiber Bragg gratings based health monitoring system of composite aerospace structures, Acta Astronaut., 69, 445, 10.1016/j.actaastro.2011.05.027
Loutas, 2015, Reliability of strain monitoring of composite structures via the use of optical fiber ribbon tapes for structural health monitoring purposes, Compos. Struct., 134, 762, 10.1016/j.compstruct.2015.08.100
Li, 2015, FBG force-testing ring for bridge cable force monitoring and temperature compensation, Sens. Actuators A Phys., 223, 105, 10.1016/j.sna.2015.01.003
Ren, 2005, Practical formulas to determine cable tension by using cable fundamental frequency, China Civ. Eng. J., 38, 26
Zhao, 2008, Influence of bending rigidity on nonlinear natural frequency of inclined cable, Eng. Mech., 25, 196
Zhang, 2007, Real-time monitor system of bridge-cable force based on fbg vibration sensor and its application, Chin. J. Sens. Actuators, 20, 2720
Yu, 2014, Design and experimental investigations of a vibration based wireless measurement system for bridge cable tension monitoring, Adv. Struct. Eng., 17, 1657, 10.1260/1369-4332.17.11.1657
Zhao, 2015, Portable and convenient cable force measurement using smartphone, J. Civ. Struct. Health Monit., 5, 481, 10.1007/s13349-015-0132-9
Guo, 2013, Welding packaged accelerometer based on metal-coated FBG, Chin. Opt. Lett., 1, 070604
Yin, 2015, Optimization design for medium-high frequency FBG accelerometer with different eigenfrequency and sensitivity, Sens. Actuators A Phys., 235, 311, 10.1016/j.sna.2015.10.018