A randomised, multi-centre, prospective, double blind pilot-study to evaluate safety and efficacy of the non-absorbable Optilene® Mesh Elastic versus the partly absorbable Ultrapro® Mesh for incisional hernia repair

Springer Science and Business Media LLC - Tập 10 - Trang 1-7 - 2010
Christoph Seiler1, Petra Baumann2, Peter Kienle3, Andreas Kuthe4, Jens Kuhlgatz5, Rainer Engemann6, Moritz v Frankenberg7, Hanns-Peter Knaebel2
1University of Heidelberg, Department of Surgery, Heidelberg, Germany
2Aesculap AG, Am Aesculap Platz, Tuttlingen, Germany
3University of Mannheim, Department of Surgery, Mannheim, Germany
4DRK-Hospital Clementinen, Hannover, Germany
5Albert-Schweitzer Hospital, Department of Surgery, Northeim, Germany
6Clinical Centre of Aschaffenburg, Department of Surgery, Aschaffenburg, Germany
7Hospital Salem, Department of Surgery, Heidelberg, Germany

Tóm tắt

Randomised controlled trials with a long term follow-up (3 to 10 years) have demonstrated that mesh repair is superior to suture closure of incisional hernia with lower recurrence rates (5 to 20% versus 20 to 63%). Yet, the ideal size and material of the mesh are not defined. So far, there are few prospective studies that evaluate the influence of the mesh texture on patient's satisfaction, recurrence and complication rate. The aim of this study is to evaluate, if a non-absorbable mesh (Optilene® Mesh Elastic) will result in better health outcomes compared to a partly absorbable mesh (Ultrapro® Mesh). In this prospective, randomised, double blind study, eighty patients with incisional hernia after a midline laparotomy will be included. Primary objective of this study is to investigate differences in the physical functioning score from the SF-36 questionnaire 21 days after mesh insertion. Secondary objectives include the evaluation of the patients' daily activity, pain, wound complication and other surgical complications (hematomas, seromas), and safety within six months after intervention. This study investigates mainly from the patient perspective differences between meshes for treatment of incisional hernias. Whether partly absorbable meshes improve quality of life better than non-absorbable meshes is unclear and therefore, this trial will generate further evidence for a better treatment of patients. NCT00646334

Tài liệu tham khảo

Conze J, Junge K, Klinge U, Krones C, Rosch R, Schumpelick V: Evidenzbasierte laparoskopische Chirurgie - Narbenhernien. Viszeralchirurgie. 2006, 41: 246-252. 10.1055/s-2006-942141.

Flum DR, Horvath K, Koepsell T: Have outcomes of incisional hernia repair improved with time? A population-based analysis. Ann Surg. 2003, 237: 129-135. 10.1097/00000658-200301000-00018.

Luijendijk RW, Hop WC, Van Den Tol MP, De Lange DC, Braaksma MM, Ijzemans JN: A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med. 2000, 343: 392-398. 10.1056/NEJM200008103430603.

Sauerland S, Schmedt CG, Lein S, Leibl BJ, Bittner R: Primary incisional hernia repair with or without polypropylene mesh: a report on 384 patients with 5-year follow-up. Langenbecks Arch Surg. 2005, 390: 408-412. 10.1007/s00423-005-0567-2.

Langer C, Liersch T, Kley C, Flosman M, Süss M, Siemer A, Becker H: [Twenty -five years of experience in incisonal hernia surgery. A comparative retrospective study of 432 incisonal hernia repairs]. Chirurg. 2003, 74: 638-645. 10.1007/s00104-002-0594-2.

Korenkov M, Sauerland S, Arndt M, Bogradi L, Neugebauer EAM, Troidl H: Randomized clinical trial of suture repair, polypropylene mesh or autodermal hernioplasty for incisional hernia. Br J Surg. 2002, 89: 50-56. 10.1046/j.0007-1323.2001.01974.x.

Liakakos T, Karanikas I, Panagiotidis H, Dendrinos S: Use of Marlex mesh in the repair of recurrent incisional hernia. Br J Surg. 1994, 81: 248-249. 10.1002/bjs.1800810230.

Kingsnorth AN, Sivarajasingham N, Wong S, Butler M: Open mesh repair of incisonal hernia with significant loss of domain. Ann R Coll Surg Engl. 2004, 86: 363-366. 10.1308/147870804236.

Conze J, Kingsnorth AN, Flament JB, Simmermacher R, Arlt G, Langer C, Schippers E, Hartley M, Schumpelick V: Randomized clinical trial comparing lightweight composite mesh with polyester or polypropylene mesh for incisional hernia repair. Br J Surg. 2005, 92: 1488-1493. 10.1002/bjs.5208.

Schug-Paß C, Tamme C, Sommerer F, Lippert H, Köckerling F: A lightweight, partially absorbable mesh (Ultrapro) for endoscopic hernia repair: experimental biocompatibility results obtained in a porcine model. Surg Endosc. 2007, 22: 1100-1106. 10.1007/s00464-007-9585-1.

Scheidbach H, Tannapfel A, Schmidt U, Lippert H, Köckerling F: Influence of titanium coating on the biocompatibility of a heavyweight polypropylene mesh. Eur Surg Res. 2004, 36: 313-317. 10.1159/000079917.

Junge K, Rosch R, Klinge U, Saklak M, Klosterhalfen B, Peiper C, Schumpelick V: Titanium coating of a polypropylene mesh for hernia repair: effect on biocompatibility. Hernia. 2005, 9: 115-119. 10.1007/s10029-004-0292-8.

Benhidjeb T, Bärlehner E, Anders S: Laparoskopische Narbenhernien-Reparation- Muss das Netz für die intraperitoneale Onlay-Mesh-technik besondere Eigenschaften haben?. Chir Gastroenterol. 2003, 19 (suppl 2): 16-22. 10.1159/000076183.

Rosen HR, Gyasi A: Retromuskuläre Kunststoff-Netz-Implantation von Narbenhernien. Chir Gastroenterol. 2003, 19 (suppl 2): 39-45. 10.1159/000076187.

Rosch R, Junge K, Stumpf M, Klinge U, Schumpelick V, Klosterhalfen B: Welche Anforderungen sollte ein ideales Netz erfüllen?. Chir Gastroenterol. 2003, 19 (suppl 2): 7-11. 10.1159/000076181.

Luijendijk RW: "Incisional hernia": risk factors, prevention, and repair (PhD.thesis). 2000, Rotterdam, The Netherlands: Erasmus University Rotterdam

Itani KMF, Neumayer L, Reda D, Kim L, Anthony T: Repair of ventral incisional hernia: the design of a randomized trial to compare open and laparoscopic surgical techniques. Am J Surg. 2004, 188: 22-29. 10.1016/j.amjsurg.2004.09.006.

Vrijland WW, Jeekel J, Steyerberg EW, Den Hoed PT, Bonjer HT: Intraperitoneal polypropylene mesh repair of incisional hernia is not associated with enterocutaneous fistula. Br J Surg. 2000, 87: 348-352. 10.1046/j.1365-2168.2000.01364.x.

Weyhe D, Belyaev O, Müller C, Meurer K, Bauer KH, Papapostolou G, Uhl W: Improving outcomes in hernia repair by the use of light meshes - a comparison of different implant constructions based on a critical appraisal of the literature. World J Surg. 2007, 31: 234-244. 10.1007/s00268-006-0123-4.

Klosterhalfen B, Junge K, Klinge U: The lightweight and large porous mesh concept for hernia repair. Expert Rev Med Device. 2005, 2: 103-117. 10.1586/17434440.2.1.103.

Langer C, Neufang T, Kley C, Schönig KH, Becker H: [Standardized sublay technique in polypropylene mesh repair of incisional hernia]. Chirurg. 2001, 72: 953-7. 10.1007/s001040170095.

Schumpelick V, Klinge U, Junge K, Stumpf M: Incisional abdominal hernia: the open mesh repair. Langenbecks Arch Surg. 2004, 389: 1-5. 10.1007/s00423-003-0352-z.

Klosterhalfen B, Klinge U, Hermanns B, Schumpelick V: Pathology of traditional surgical nets for hernia repair after longterm implantation in humans. Chirurg. 2000, 71: 43-51.

Klosterhalfen B, Klinge U, Hermanns B, Schumpelick V: Pathology of traditional surgical nets for hernia repair after longterm implantation in humans. Chirurg. 2000, 71: 43-51.

The pre-publication history for this paper can be accessed here:http://www.biomedcentral.com/1471-2482/10/21/prepub