An investigation of thermophysiological responses of human while using four personal cooling strategies during heatwaves

Journal of Thermal Biology - Tập 70 - Trang 37-44 - 2017
Faming Wang1, Wenfang Song2
1Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hung Hom, Hom, Kowloon, Hong Kong
2Honeywell China Co. Ltd., Pudong District, Shanghai 201203, China

Tài liệu tham khảo

Ainsworth, 2000, Compendium of physical activities: an update of activity code and MET intensities, Med. Sci. Sports Exerc., 32, S498, 10.1097/00005768-200009001-00009

American Society for Testing and Materials (ASTM), 2016. ASTMF2371-2016, Standard Test Method for Measuring the Heat removal rate of Personal Cooling Systems Using a Sweating Heated Manikin. ASTM International, West Conshocken, PA, USA.

Bartkowiak, 2015, Construction of a garment for an integrated liquid cooling system, Text. Res. J., 85, 1809, 10.1177/0040517515576324

Barwood, 2009, Ventilated vest and tolerance for intermittent exercise in hot, dry conditions with military clothing, Aviat. Space Environ. Med., 80, 353, 10.3357/ASEM.2411.2009

Blood, K., Burke, R., 2010. Further validation of the model-controlled Newton thermal manikin against historical human studies. In: Proceedings of the 8th International Meeting on Thermal Manikin and Modeling (8i3m). Victoria, Canada, pp. 1–5.

Bowler, 1981, Heat death and cellular heat injury, J. Therm. Biol., 6, 171, 10.1016/0306-4565(81)90002-4

Burke, R., Blood, K., Deaton, A.S., Barker, R., 2010. Application of model-controlled manikin to predict human physiological response in firefighter turnout gear. In: Proceedings of the 8th International Meeting on Thermal Manikin and Modeling (8i3m). Victoria, Canada, pp. 1–6.

Burke, R., Curran, A., Hepokoski, M., 2009. Integrating an active physiological and comfort model to the Newton sweating thermal manikin. In: Proceedings of the 13th International Conference on Environmental Ergonomics (ICEE). Wollongong, Australia, pp. 313–317.

Caldwell, 2012, Evectional thermal strain, protective clothing and auxiliary cooling in dry heat: evidence for physiological but not cognitive impairment, Eur. J. Appl. Physiol., 112, 3597, 10.1007/s00421-012-2340-x

Chan, 2015, Meta-analysis of the effects of microclimate cooling systems on human performance under thermal stressful environments: potential applications to occupational workers, J. Therm. Biol., 49–50, 16, 10.1016/j.jtherbio.2015.01.007

Cheung, 1998, Heat acclimation, aerobic fitness, and hydration effects on tolerance during uncompensable heat stress, J. Appl. Physiol., 84, 1731, 10.1152/jappl.1998.84.5.1731

Fiala, 1999, A computer model of human thermoregulation for a wide range of environmental conditions: the passive system, J. Appl. Physiol., 87, 1957, 10.1152/jappl.1999.87.5.1957

Gao, 2010, Cooling vests with phase change material packs: the effects of temperature gradient, mass and covering area, Ergonomics, 53, 716, 10.1080/00140130903581649

Gao, C., Kuklane, K., Holmér, I., 2010b. Thermoregulatory manikins are desirable for evaluations of intelligent clothing and smart textiles. In: Proceedings of the 8th International Meeting for Manikins and Modeling (8I3M). Victoria, BC, Canada, pp. 1–5.

Gao, 2012, Personal cooling with phase change materials to improve thermal comfort from a heat wave perspective, Indoor Air, 22, 523, 10.1111/j.1600-0668.2012.00778.x

Hepokoski, M., Curran, A., Burke, R., Rugh, J., 2015. Simulating physiological response with a passive sensor manikin and an adaptive thermal manikin to predict thermal sensation and comfort. SAE Technical Paper 2015-01-0329, doi:10.4271/2015-01-0329.

Kenney, 2014, Heat waves, aging, and human cardiovascular health, Med. Sci. Sports Exerc., 46, 1891, 10.1249/MSS.0000000000000325

Kenny, 2013, Thermometry, calorimetry, and mean body temperature during heat stress, Compr. Physiol., 3, 1689, 10.1002/cphy.c130011

Kenny, 2011, Ice cooling vest on tolerance for exercise under uncompensable heat stress, J. Occup. Environ. Hyg., 8, 484, 10.1080/15459624.2011.596043

Kim, 2011, Subjective perceptions and ergonomics evaluation of a liquid cooled garment worn under protective ensemble during an intermittent treadmill exercise, Ergonomics, 54, 626, 10.1080/00140139.2011.583362

Lai, 2017, Evaluation of a hybrid personal cooling system using a manikin operated in constant temperature mode and thermoregulatory model control mode in warm conditions, Text. Res. J., 87, 46, 10.1177/0040517515622152

Lancet, 2015, Health professionals: be prepared for heatwaves, Lancet, 386, 219, 10.1016/S0140-6736(15)61261-2

Li, 2015, Heat waves and morbidity: current knowledge and further direction-a comprehensive literature review, Int. J. Environ. Res. Public Health, 12, 1231, 10.3390/ijerph120505256

Lu, 2015, A novel personal cooling system (PCS) incorporated with phase change materials (PCMs) and ventilation fans: an investigation on its cooling efficiency, J. Therm. Biol., 52, 137, 10.1016/j.jtherbio.2015.07.002

Murari, 2015, Intensification of future severe heat waves in India and their effect on heat stress and mortality, Reg. Environ. Change, 15, 569, 10.1007/s10113-014-0660-6

Oliveira, 2008, Measurement of clothing insulation with a thermal manikin operating under the thermal comfort regulation mode: comparative analysis of the calculation methods, Eur. J. Appl. Physiol., 104, 679, 10.1007/s00421-008-0824-5

Ravanelli, 2015, Heart rate and body temperature responses to extreme heat and humidity with and without electric fans, J. Am. Med. Assoc. (JAMA), 313, 724, 10.1001/jama.2015.153

Richards, M.G.M., Psikuta, A., Fiala, D., 2006. Current development of thermal sweating manikins at Empa. In: Proceedings of the 6th International Meeting on Thermal Manikin and Modeling (6i3m). Hong Kong, pp. 173–179.

Salim, 2015, Deadly heat wave in Karachi, July 2015: negligence or mismanagement?, Int. J. Occup. Environ. Med., 6, 249, 10.15171/ijoem.2015.678

Saunders, 2005, The effects of different air velocities on heat storage and body temperature in humans cycling in a hot, humid environment, Acta Physiol. Scand., 183, 241, 10.1111/j.1365-201X.2004.01400.x

Semeniuk, 2005, Evaluating the physiological performance of a liquid cooling garment used to control heat stress in hazmat protective ensembles, J. ASTM Int., 2, 1, 10.1520/JAI12103

Song, 2016, The hybrid personal cooling system (PCS) could effectively reduce the heat strain while exercising in a hot and moderate humid environment, Ergonomics, 59, 1009, 10.1080/00140139.2015.1105305

Song, 2016, Hybrid cooling clothing to improve thermal comfort of office workers in a hot indoor environment, Build. Environ., 100, 92, 10.1016/j.buildenv.2016.02.009

Tham, 2010, Performance evaluation of the coupling of a desktop personalized ventilation air terminal device and desk mounted fans, Build. Environ., 45, 1941, 10.1016/j.buildenv.2010.01.019

U.S. Environmental Protection Agency, 2016. 〈https://www.epa.gov/sites/production/files/2016[HYPHEN]03/documents/eheguide_final.pdf〉 (accessed: 31 July 2016).

Wang, F., Zhang, C., 2016. Physiological responses predicted by thermoregulatory model controlled manikin: does simulation of body posture make a difference? In: Proceedings of the 11th International Meeting on Thermal Manikin and Modelling (11i3m). Suzhou, China, pp. 69–70.