thumbnail

Cardiovascular Ultrasound

  1476-7120

 

 

Cơ quản chủ quản:  BMC , BioMed Central Ltd.

Lĩnh vực:
Medicine (miscellaneous)Radiology, Nuclear Medicine and ImagingCardiology and Cardiovascular Medicine

Phân tích ảnh hưởng

Thông tin về tạp chí

 

Các bài báo tiêu biểu

Assessment of inpatient multimodal cardiac imaging appropriateness at large academic medical centers
Tập 13 - Trang 1-8 - 2015
Andrew Remfry, Howard Abrams, David M. Dudzinski, Rory B. Weiner, R. Sacha Bhatia
Responding to concerns regarding the growth of cardiac testing, the American College of Cardiology Foundation (ACCF) published Appropriate Use Criteria (AUC) for various cardiac imaging modalities. Single modality cardiac imaging appropriateness has been reported but there have been no studies assessing the appropriateness of multiple imaging modalities in an inpatient environment. A retrospective study of the appropriateness of cardiac tests ordered by the inpatient General Internal Medicine (GIM) and Cardiology services at three Canadian academic hospitals was conducted over two one-month periods. Cardiac tests characterized were transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), single-photon emission tomography myocardial perfusion imaging (SPECT), and diagnostic cardiac catheterization. Overall, 553 tests were assessed, of which 99.8 % were classifiable by AUC. 91 % of all studies were categorized as appropriate, 4 % may be appropriate and 5 % were rarely appropriate. There were high rates of appropriate use of all modalities by GIM and Cardiology throughout. Significantly more appropriate diagnostic catheterizations were ordered by Cardiology than GIM (93 % vs. 82 %, p = <0.01). Cardiology ordered more appropriate studies overall (94 % vs. 88 %, p = 0.03) but there was no difference in the rate of rarely appropriate studies (3 % vs. 6 %, p = 0.23). The ACCF AUC captured the vast majority of clinical scenarios for multiple cardiac imaging modalities in this multi-centered study on Cardiology and GIM inpatients in the acute care setting. The rate of appropriate ordering was high across all imaging modalities. We recommend further work towards improving appropriate utilization of cardiac imaging resources focus on the out-patient setting.
The feasibility, reliability, and incremental value of two-dimensional speckle-tracking for the detection of significant coronary stenosis after treadmill stress echocardiography
- 2021
Marc-André d’Entremont, Gabriel Fortin, Thao Huynh, Étienne Croteau, Paul Farand, Samuel Lemaire-Paquette, Marie-Claude Brochu, Doan Hoa Do, Serge Lepage, Warner Mbuila Mampuya, Étienne L. Couture, Michel Nguyen, Btissama Essadiqi
Two-dimensional speckle-tracking echocardiography (STE) may help detect coronary artery disease (CAD) when combined with dobutamine stress echocardiography. However, few studies have explored STE with exercise stress echocardiography (ESE). We aimed to evaluate the feasibility, reliability, and incremental value of STE combined with treadmill ESE compared to treadmill ESE alone to detect CAD. We conducted a case–control study of all consecutive patients with abnormal ESE in 2018–2020 who subsequently underwent coronary angiography within a six-month interval. We 1:1 propensity score-matched these patients to those with a normal ESE. Two blinded operators generated a 17-segment bull's-eye map of longitudinal strain (LS). We utilized the mean differences between stress and baseline LS values in segments 13–17, segment 17, and segments 15–16 to create receiver operator curves for the overall examination, the left anterior descending artery (LAD), and the non-LAD territories, respectively. We excluded 61 STEs from 201 (30.3%) eligible ESEs; 47 (23.4%) because of suboptimal image quality and 14 (7.0%) because of excessive heart rate variability precluding the calculation of a bull's-eye map. After matching, a total of 102 patients were included (51 patients in each group). In the group with abnormal ESE patients (mean age 66.4 years, 39.2% female), 64.7% had significant CAD (> 70% stenosis) at coronary angiogram. In the group with normal ESE patients (mean age 65.1 years, 35.3% female), 3.9% were diagnosed with a new significant coronary stenosis within one year. The intra-class correlation for global LS was 0.87 at rest and 0.92 at stress, and 0.84 at rest, and 0.89 at stress for the apical segments. The diagnostic accuracy of combining ESE and STE was superior to visual assessment alone for the overall examination (area under the curve (AUC) = 0.89 vs. 0.84, p = 0.025), the non-LAD territory (AUC = 0.83 vs. 0.70, p = 0.006), but not the LAD territory (AUC = 0.79 vs. 0.73, p = 0.11). Two-dimensional speckle-tracking combined with treadmill ESE is relatively feasible, reliable, and may provide incremental diagnostic value for the detection and localization of significant CAD.
Echocardiographic predictors of intraoperative right ventricular dysfunction: a 2D and speckle tracking echocardiography study
- 2019
Lisa Q. Rong, Brian Yum, Christiane Abouzeid, Maria Chiara Palumbo, Lillian R. Brouwer, Richard B. Devereux, Leonard N. Girardi, Jonathan W. Weinsaft, Mario Gaudino, Jiwon Kim
Hypercholesterolemia and Myocardial function evaluated via Tissue Doppler Imaging
Tập 7 - Trang 1-7 - 2009
Jack Rubinstein, Augusta Pelosi, Ameeth Vedre, Pavan Kotaru, George S Abela
To establish a link between hypercholesterolemia and myocardial dysfunction. Heart failure is a complex disease involving changes in systolic and diastolic function. Newer echocardiographic imaging modalities may be able to detect discreet changes in myocardial function associated with hypercholesterolemia. Therefore we sought to establish a link between hypercholesterolemia and myocardial dysfunction with tissue Doppler imaging (TDI). Twenty-seven rabbits were studied: 7 were fed normal chow (group 1) and 20 a high cholesterol diet (10 with ezetimibe, 1 mg/kg/day; group 2 and 10 without, group 3). Echocardiographic images were obtained under general anesthesia. Serum cholesterol levels were obtained at baseline, 3 and 6 months and myocardial cholesterol levels measured following euthanasia. Doppler measurements, including E/A, E'/A' and S' were significantly lower in group 3 compared to both groups 1 and 2 but no significant differences were noted in chamber sizes or ejection fraction among the groups. Average serum cholesterol was higher in group 3 compared to groups 1 and 2 respectively (495 ± 305 mg/dl vs. 114 ± 95 mg/dl and 87 ± 37 mg/dl; p < 0.01). Myocardial cholesterol content was also higher in group 3 compared to group 2 (0.10 ± 0.04 vs. 0.06 mg/dl ± 0.02; p = 0.05). There was significant correlation between S', E'/A', E/E' and serum cholesterol (r2 = 0.17 p = 0.04, r2 = 0.37 p = 0.001 and r2 = 0.24 p = 0.01). Cholesterol load in the serum and myocardium was significantly associated with decreased systolic and diastolic function by TDI. Moreover, lipid lowering was protective.
Correlation between coronary artery disease severity, left ventricular mass index and carotid intima media thickness, assessed by radio-frequency
- 2011
Marco Matteo Ciccone, Pietro Scicchitano, Annapaola Zito, Luciano Agati, Michele Gesualdo, S Mandolesi, Roberta Carbonara, Francesco Ciciarello, Francesco Fedele
Comparison of normal values of Duplex indices of vertebral arteries in young and elderly adults
Tập 7 Số 1 - Trang 1-3 - 2009
Nemati, Masoud, Bavil, Abolhassan Shakeri, Taheri, Naser
Considering the role of aging in brain atrophy and cerebral vascular demand, we carried out this study to clarify the role of aging in duplex indices of vertebral arteries. From June 2005 to June 2006, 96 volunteers with age range of 20 to 95 years, were evaluated with color doppler for duplex indices of vertebral arteries. Sever hemodynamic stenosis was excluded in all of these patients. These volunteers were subdivided in two groups: younger and older than 60 year old. In all of these patients we measured diameter, peak systolic velocity (PSV), resistive index (RI), and flow volume (FV) of vertebral arteries in right and left sides. There was no significant difference in diameter, PSV, RI and FV between two groups. We have clarified that in patients younger than 60 year old, comparing right and left vertebral arteries, PSV and FV were higher in left side. Duplex indices of vertebral arteries are age independent in adults.
The effects of beta-blockers on dobutamine-atropine stress echocardiography: early protocol versus standard protocol
- 2006
Ana C Camarozano, Plínio Resende, Aristarco G Siqueira-Filho, Luis H Weitzel, Rosangela Noe
To study the effects of Beta-blockers during Dobutamine Stress Echocardiography (DSE) comparing the hemodynamic benefits of an early administration of atropine in patients taking or not Beta-blockers. One hundred and twenty-one patients were submitted to dobutamine stress echocardiography for the investigation of myocardial ischemia. The administration of atropine was randomized into two groups: A or B (early protocol when atropine was administered at 10 and 20 mcg/kg/min of dobutamine, respectively) and C (standard protocol with atropine at 40 mcg/kg/min of dobutamine). Analysis of the effects of Beta-blockers was done regarding the behavior pattern of heart rate and blood pressure, test time, number of conclusive and inconclusive (negative sub-maximum test) results, total doses of atropine and dobutamine, and general complications. Beta-blocked patients who received early atropine (Group A&B) had a significantly lower double product (p = 0.008), a higher mean test time (p = 0.010) and required a higher dose of atropine (p = 0.0005) when compared to the patients in this group who were not Beta-blocked. The same findings occurred in the standard protocol (Group C), however the early administration of atropine reduced test time both in the presence and absence of this therapy (p = 0.0001). The patients with Beta-blockers in Group A&B had a lower rate of inconclusive tests (26%) compared to those in Group C (40%). Complications were similar in both groups. The chronotropic response during dobutamine stress echocardiography was significantly reduced with the use of Beta-blockers. The early administration of atropine optimized the hemodynamic response, reduced test time in patients with or without Beta-blockers and reduced the number of inconclusive tests in the early protocol.
Feasibility and accuracy of a novel automated three-dimensional ultrasonographic analysis system for abdominal aortic aneurysm: comparison with two-dimensional ultrasonography and computed tomography
Tập 18 - Trang 1-11 - 2020
In-Jeong Cho, Jinyong Lee, Jinki Park, Sang-Eun Lee, Chul-Min Ahn, Young-Guk Ko, Donghoon Choi, Hyuk-Jae Chang
Accurate measurement of the maximum aortic diameter (Dmax) is crucial for patients with abdominal aortic aneurysm (AAA). Aortic computed tomography (CT) provides accurate Dmax values by three-dimensional (3-D) reconstruction but may cause nephrotoxicity because of contrast use and radiation hazard. We aimed to evaluate the accuracy of a novel semi-automated 3-D ultrasonography (3-D US) system compared with that of CT as a reference. Patients with AAA (n = 59) or individuals with normal aorta (n = 18) were prospectively recruited in an outpatient setting. Two-dimensional ultrasonography (2-D US) and 3-D US images were acquired with a single-sweep volumetric transducer. The analysis was performed offline with a software. Dmax and the vessel area of the Dmax slice were measured with 2-D US, 3-D US, and CT. The lumen and thrombus areas of the Dmax slice were also measured in 40 patients with intraluminal thrombus. Vessel and thrombus volumes were measured using 3-D US and CT. The Dmax values from 3-D US demonstrated better agreement (R2 = 0.984) with the CT values than with the 2-D US values (R2 = 0.938). Overall, 2-D US underestimated Dmax compared with 3-D US (32.3 ± 12.1 mm vs. 35.1 ± 12.0 mm). The Bland-Altman analysis of the 3-D US values, revealed better agreement with the CT values (2 standard deviations [SD], 2.9 mm) than with the 2-D US values (2 SD, 5.4 mm). The vessel, lumen, and thrombus areas all demonstrated better agreement with CT than with 2-D US (R2 = 0.986 vs. 0.960 for the vessel, R2 = 0.891 vs. 0.837 for the lumen, and R2 = 0.977 vs. 0.872 for the thrombus). The thrombus volume assessed with 3-D US showed good correlation with the CT value (R2 = 0.981 and 2 SD in the Bland-Altman analysis: 13.6 cm3). Our novel semi-automated 3-D US analysis system provides more accurate Dmax values than 2-D US and provides precise volumetric data, which were not evaluable with 2-D US. The application of the semi-automated 3-D US analysis system in abdominal aorta assessment is easy and accurate.
Comparison of echocardiographic (US) volumetry with cardiac magnetic resonance (CMR) imaging in transfusion dependent thalassemia major (TM)
Tập 5 - Trang 1-6 - 2007
Anastasios Giakoumis, Vasilis Berdoukas, Efstathios Gotsis, Athanassios Aessopos
Despite advances in survival in patients with thalassemia major (TM) the most common cause of death is cardiac disease. Regular cardiac follow-up is imperative in order to identify and reverse pathology. Cardiac Magnetic Resonance (CMR) and Echocardiography (US) are applied in parallel to TM patients for cardiac evaluation and ongoing monitoring. A comparison between mutual features would be useful in order to assess the accuracy and reliability of the two methods, with a particular focus on routine US application. TM's special attributes offer an excellent opportunity for cardiac imaging research that has universal general purpose applications. 135 TM patients underwent US (Teichholz's M-mode formula – rapidly accessible means of measuring volumes and ejection fraction) and CMR volumetry. Paired-samples t-test, Passing & Badlock regression and Bland & Altman plot were used while comparing the common parameters between the CMR and the US. We found that the US volumes were underestimated, especially the end-diastolic volume (p < 0.001). The end-systolic volume showed a borderline two-tailed probability (p ≈ 0.05). The correlation for the ejection fraction was acceptable (r = 0.60) without a statistically significant difference (p = 0.37) and the Bland Altman plot range was narrow (25.8%). There was a satisfactory correlation of the US' shortening fraction with CMR's ejection fraction (r = 0.58). In cases where cardiac wall movement abnormalities are absent, the US Teichholz's M-mode formula for volume measurements, though less sophisticated in comparison to the high resolution CMR technique, offers an adequate ejection fraction estimation for routine use, especially when monitoring gross alterations in cardiac function over time, and is easy to perform.
Contribution of sarcomere gene mutations to left atrial function in patients with hypertrophic cardiomyopathy
- 2021
Hyemoon Chung, Yoonjung Kim, Chul Hwan Park, In Soo Kim, Jong Youn Kim, Pil‐Ki Min, Young Won Yoon, Tae Hoon Kim, Byoung Kwon Lee, Bum‐Kee Hong, Se Joong Rim, Hyuck Moon Kwon, Kyung A. Lee, Eui‐Young Choi
Abstract Background Left atrial (LA) enlargement and dysfunction are related to clinical course in patients with hypertrophic cardiomyopathy (HCM). We aimed to investigate genetic contribution to LA structural and functional remodeling. Methods Two hundred twelve patients were consecutively enrolled, and echocardiography and extensive genetic analysis were performed. Cardiac magnetic resonance (CMR) was performed in 135 patients. Echocardiography was also performed in controls (n = 30). Results Patients with HCM had lower late-diastolic mitral annular velocity (a’) and higher LA volume index (LAVI) than controls. Patients with pathogenic or likely pathogenic sarcomere gene mutations (PSM, n = 67, 32%) had higher LAVI and lower CMR-derived LA total emptying fraction (37.0 ± 18.5 vs. 44.2 ± 12.4%, p = 0.025). In patients without AF (n = 187), the PSM had lower a’ (6.9 ± 2.0 vs. 7.8 ± 1.9 cm/s, p = 0.004) than others. The PSM had higher prevalence and amount of late gadolinium enhancement (LGE) in the left ventricle (LV). In multivariate analysis, PSM was significantly related to lower a’ independent of E/e’, LV mass index, and LAVI. However, the relation significantly attenuated after adjustment for the extent of LGE in the LV, suggesting common myopathy in the LV and LA. In addition, PSM was significantly related to lower LA total emptying fraction independent of age, E/e’, s’, LV ejection fraction, LV myocardial global longitudinal strain and %LGE mass. Conclusions PSM was related to LA dysfunction independent of LV filling pressure and LAVI, suggesting its contribution to atrial myopathy in HCM.