Transient elastography: a new noninvasive method for assessment of hepatic fibrosis

Ultrasound in Medicine & Biology - Tập 29 Số 12 - Trang 1705-1713 - 2003
Laurent Sandrin1, Bertrand Fourquet1, Jean-Michel Hasquenoph1, Sylvain Yon1, Céline Fournier1, F Mal2, Christos Christidis2, Marianne Ziol2, B. Poulet2, Farhad Kazemi2, Michel Beaugrand2, R Palau3
1Echosens, Paris, France
2Hôpital Jean Verdier, Bondy Cedex, France
3Institut Mutualiste Montsouris, Paris, France

Tóm tắt

Từ khóa


Tài liệu tham khảo

Abdi, 1979, Sampling variability on percutaneous liver biopsy, Arch Intern Med, 139, 667, 10.1001/archinte.139.6.667

Bedossa, 1996, An algorithm for grading of activity in chronic hepatitis C, Hepatology, 24, 289, 10.1002/hep.510240201

Bercoff J, Tanter M, Fink M. Supersonic imaging: a new technique for mapping of the visco-elastic properties of tissues. 28th International Symposium on Ultrasonic Imaging and Tissue Characterization, Arlington, VA, May 28–30, 2003. Ultrason Imaging 2003

Bravo, 2001, Liver biopsy, N Engl J Med, 344, 495, 10.1056/NEJM200102153440706

Cadranel, 2000, Practices of liver biopsy in France, Hepatology, 32, 477, 10.1053/jhep.2000.16602

Catheline, 1999, Diffraction field of a low-frequency vibrator in soft tissues using transient elastography, IEEE Trans Ultrason Ferroelectr Freq Control, 46, 1013, 10.1109/58.775668

Catheline, 1999, A solution to diffraction biases in sonoelasticity, J Acoust Soc Am, 105, 2941, 10.1121/1.426907

Cespedes, 1993, Elastography, Ultrason Imaging, 15, 73, 10.1006/uimg.1993.1007

Chen, 1996, Young's modulus measurements of soft tissues with application to elasticity imaging, IEEE Trans Ultrason Ferroelectr Freq Control, 43, 191, 10.1109/58.484478

Friedman, 2003, Liver fibrosis—from bench to bedside, J Hepatol, 38, S38, 10.1016/S0168-8278(02)00429-4

Fung, 1981

Glüer, 1995, Accurate assessment of precision errors, Osteopor Int, 5, 262, 10.1007/BF01774016

Jensen JA. Estimation of blood velocities using ultrasound. Cambridge: Cambridge University Press, 1996

Krouskop, 1998, Elastic moduli of breast and prostate tissue under compression, Ultrason Imaging, 20, 260, 10.1177/016173469802000403

Lerner, 1987, Sono-elasticity, Acoust Imaging, 16, 317, 10.1007/978-1-4613-0725-9_31

Levinson, 1995, Sonoelastic determination of human skeletal muscle elasticity, J Biomech, 28, 1145, 10.1016/0021-9290(94)00173-2

Lorenzen, 2003, Menstrual-cycle dependence of breast parenchyma elasticity, Invest Radiol, 38, 236, 10.1097/01.RLI.0000059544.18910.BD

Maharaj, 1986, Sampling variability and the influence on the diagnostic yield of percutaneous needle biopsy of the liver, Lancet, 1, 523, 10.1016/S0140-6736(86)90883-4

Metz, 1978, Basic principles of ROC analysis, Semin Nucl Med, 8, 283, 10.1016/S0001-2998(78)80014-2

Muthupillai, 1995, Magnetic resonance elastography by direct visualization of propagating acoustic strain waves, Science, 269, 1854, 10.1126/science.7569924

Nightingale, 2001, On the feasibility of remote palpation using acoustic radiation force, J Acoust Soc Am, 110, 625, 10.1121/1.1378344

Nord, 1982, Biopsy diagnosis of cirrhosis, Gastrointest Endosc, 28, 102, 10.1016/S0016-5107(82)73015-9

Ophir, 1991, Elastography, Ultrason Imaging, 13, 111, 10.1016/0161-7346(91)90079-W

Parker, 1998, Vibration sonoelastography and the detectability of lesions, Ultrasound Med Biol, 24, 1437, 10.1016/S0301-5629(98)00123-9

Parker, 1990, Tissue response to mechanical vibrations for sonoelasticity imaging, Ultrasound Med Biol, 16, 241, 10.1016/0301-5629(90)90003-U

Poynard, 2000, Appropriateness of liver biopsy, Can J Gastroenterol, 14, 543, 10.1155/2000/107982

Royer, 2000

Rudenko, 1996, Acoustic radiation force and streaming induced by focused nonlinear ultrasound in a dissipative medium, J Acoust Soc Am, 99, 2791, 10.1121/1.414805

Sanada, 2000, Clinical evaluation of sonoelasticity measurement in liver using ultrasonic imaging of internal forced low-frequency vibration, Ultrasound Med Biol, 26, 1455, 10.1016/S0301-5629(00)00307-0

Sandrin, 1999, Time-resolved pulsed elastography, Ultrason Imaging, 21, 259, 10.1177/016173469902100402

Sandrin, 2002, Shear modulus imaging with 2D transient elastography, IEEE Trans Ultrason Ferroelec Freq Control, 49, 426, 10.1109/58.996560

Sandrin, 2002, Shear elasticity probe for soft tissues with 1D transient elastography, IEEE Trans Ultrason Ferroelec Freq Control, 49, 436, 10.1109/58.996561

Sarvazyan AP. A new approach to remote ultrasonic evaluation of viscoelastic properties of tissues for diagnostics and healing monitoring. Abstract of ARPA/ONR Medical Ultrasonic Imaging Technology Workshop, Landsdowne, Virginia, January, 1995. 1995:24-26

Soloway, 1971, Observer error and sampling variability tested in evaluation of hepatitis and cirrhosis by liver biopsy, Am J Dig Dis, 16, 1082, 10.1007/BF02235164

Walker, 1994, A fundamental limit on the performance of correlation based on phase correction and flow estimation techniques, IEEE Trans Ultrason Ferroelec Freq Control, 41, 644, 10.1109/58.308499

Yamakoshi Y, Suzuki M, Sato T. Imaging the elastic properties using low frequency vibration and probing ultrasonic wave. Japanese Meeting of Applied Physics, Tokyo, 1987

Yamakoshi, 1990, Ultrasonic imaging of internal vibration of soft tissue under forced vibration, IEEE Trans Ultrason Ferroelec Freq Control, 37, 45, 10.1109/58.46969

Yeh, 2002, Elastic modulus measurements of human liver and correlation with pathology, Ultrasound Med Biol, 28, 467, 10.1016/S0301-5629(02)00489-1