Single prediction equation for bioelectrical impedance analysis in adults aged 20–94 years

Nutrition - Tập 17 Số 3 - Trang 248-253 - 2001
Ursula G. Kyle1, Laurence Genton1, Laurie Karsegard1, Daniel O. Slosman2, Claude Pichard1
1Clinical Nutrition and Dietetics and Geneva University Hospital, Geneva, Switzerland
2Nuclear Medicine, Geneva University Hospital, Geneva, Switzerland

Tóm tắt

Từ khóa


Tài liệu tham khảo

Segal, 1988, Lean body mass estimation by bioelectrical impedance analysis, Am J Clin Nutr, 47, 7, 10.1093/ajcn/47.1.7

Kyle, 2000, Dynamic assessment of fat-free mass during catabolism and recovery, Curr Opin Clin Nutr Metab Care, 3, 317, 10.1097/00075197-200007000-00013

Kushner, 1986, Estimation of total body water by bioelectrical impedance analysis, Am J Clin Nutr, 44, 417, 10.1093/ajcn/44.3.417

Lukaski, 1985, Assessment of fat-free mass using bioelectrical impedance measurements of the human body, Am J Clin Nutr, 41, 810, 10.1093/ajcn/41.4.810

Lukaski, 1986, Validation of tetrapolar bioelectrical impedance measurements to assess human body composition, J Appl Physiol, 60, 1327, 10.1152/jappl.1986.60.4.1327

Van Loan, 1987, Bioelectrical impedance analysis. Is it a reliable estimator of lean body mass and total body water?, Hum Biol, 2, 299

Jackson, 1988, Reliability and validity of bioelectrical impedance in determining body composition, J Appl Physiol, 64, 529, 10.1152/jappl.1988.64.2.529

Lukaski, 1988, Estimation of body fluid volumes using tetrapolar bioelectrical measurements, Aviat Space Environ Med, 59, 1163

Graves, 1989, Comparison of different bioelectrical impedance analyzers in the prediction of body composition, Am J Hum Biol, 1, 603, 10.1002/ajhb.1310010511

Heitmann, 1990, Prediction of body water and fat in adult danes from measurement of electrical impedance. A validation, Int J Obes, 14, 417

Deurenberg, 1990, Assessment of body composition by bioelectrical impedance in a population aged >60 y, Am J Clin Nutr, 51, 3, 10.1093/ajcn/51.1.3

Deurenberg, 1991, Sex and age specific prediction formulas for estimating body composition from bioelectrical impedance, Int J Obes, 15, 17

Roubenoff, 1997, Application of bioelectrical impedance analysis to elderly population, J Gerontol, 52A, M129, 10.1093/gerona/52A.3.M129

Stolarczyk, 1997, The fatness-specific bioelectrical impedance analysis equations of Segal et al, Am J Clin Nutr, 66, 8, 10.1093/ajcn/66.1.8

Pichard, 1999, Fat-free mass in chronic illness, Nutrition, 15, 668, 10.1016/S0899-9007(99)00122-7

Pichard, 1997, Body composition by x-ray absorptiometry and bioelectrical impedance in chronic respiratory insufficiency patients, Nutrition, 13, 952, 10.1016/S0899-9007(97)00336-5

Kyle, 1998, New bioelectrical impedance formula for patients with respiratory insufficiency, Eur Resp J, 12, 960, 10.1183/09031936.98.12040960

Pichard, 1997, Body composition by X-ray absorptiometry and bioelectrical impedance in elite female runners, Med Sci Sports Exerc, 29, 1527, 10.1097/00005768-199711000-00021

Hansen, 1993, Prediction of body composition in premenopausal females from dual-energy X-ray absorptiometry, J Appl Physiol, 75, 1637, 10.1152/jappl.1993.75.4.1637

Lewis, 1994, Patient dose in dual x-ray absorptiometry, Osteoporos Int, 4, 11, 10.1007/BF02352255

Blake, 1996, New generation dual x-ray absorptiometry scanners increase dose to patients and staff, J Bone Mineral Res, 11, S157

Mazess, 1990, Total body composition by dual-photon (153 Gd) absorptiometry, Am J Clin Nutr, 40, 834, 10.1093/ajcn/40.4.834

Slosman, 1992, Assessment of whole-body composition using dual X-ray absorptiometry, Radiology, 185, 593, 10.1148/radiology.185.2.1410379

Heymsfield, 1989, Dual-photon absorptiometry, Am J Clin Nutr, 49, 1283, 10.1093/ajcn/49.6.1283

Kerlinger FN, Pedhazur EJ. Multiple regression in behavioral research. New York: Holt, Rinehard & Winston, 1973

Wang, 1998, Six-compartment body composition model, Int J Obes, 22, 329, 10.1038/sj.ijo.0800590

Wellens, 1993, Body composition in white adults by dual energy X-ray absorptiometry, densitometry, and total body water, Eur J Clin Nutr, 59, 547

Bland, 1986, Statistical methods for assessing agreement between two methods of clinical measurement, Lancet, i, 307, 10.1016/S0140-6736(86)90837-8

Kushner, 1992, Is the impedance index (ht2/R) significant in predicting total body water?, Am J Clin Nutr, 56, 835, 10.1093/ajcn/56.5.835

Mazess, 1990, Dual-energy X-ray absorptiometry for total-body and regional bone-mineral and soft-tissue composition, Am J Clin Nutr, 51, 1106, 10.1093/ajcn/51.6.1106

Heitmann, 1990, Prediction of body water and fat in adult Danes from measurement of electrical impedance. A validation study, Int J Obes, 14, 789

Kyle UG, Genton L, Karsegard L, et al. Cross-sectional changes in fat-free mass, skeletal muscle, body cell mass and fat mass between 18–94 yrs. Eur J Clin Nutr (in press)

Hewitt, 1989, Estimation of total body water by bioelectrical impedance analysis in older men and women, Med Sci Sports Exerc, 21, S74, 10.1249/00005768-198904001-00440

Baumgartner, 1991, Body composition in elderly people, Am J Clin Nutr, 53, 1345, 10.1093/ajcn/53.6.1345

Roubenoff, 1996, Applications of bioelectrical impedance analysis for body composition to epidemiologic studies, Am J Clin Nutr, 64, 459S, 10.1093/ajcn/64.3.459S

Laskey, 1992, The influence of tissue depth and composition on the performance of the Lunar dual-energy X-ray absorptiometer whole-body scanning mode, Eur J Clin Nutr, 46, 39

Fuller, 1992, Four-component model for the assessment of body composition in humans, Clin Sci, 82, 687, 10.1042/cs0820687