Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: A clinical validation study

Journal of the American College of Cardiology - Tập 22 Số 5 - Trang 1455-1464 - 1993
Daniel S. Berman1, Hosen Kiat1, John D. Friedman1, Fan Ping Wang1, Kenneth Van Train1, Lisa Matzer1, Jamshid Maddahi1, Guido Germano1
1From the Departments of Imaging (Division of Nuclear Medicine) and Medicine (Division of Cardiology), Cedars-Sinai Medical Center and Department of Medicine, University of California School of Medicine, Los Angeles, California USA

Tóm tắt

Từ khóa


Tài liệu tham khảo

Iskandrian, 1989, Use of technetium-99m isonitrile (RP-30A) in assessing left ventricular perfusion and function at rest and during exercise in coronary artery disease, and comparison with coronary arteriography and exercise thallium-201 SPECT imaging, Am J Cardiol, 64, 270, 10.1016/0002-9149(89)90518-3

Kahn, 1989, Quantitative rotational tomography with T1-201 and Tc-99m 2-methoxy-isobutyl-isonitrile: a direct comparison in normal individuals and patients with coronary artery disease, Circulation, 79, 1282, 10.1161/01.CIR.79.6.1282

Kiat, 1990, Development and prospective application of quantitative 2-day stress-rest Tc-99m methoxy isobutyl isonitrile SPECT for the diagnosis of coronary artery disease, Am Heart J, 120, 1255, 10.1016/0002-8703(90)90234-O

Berman, 1991, The new 99m-Tc myocardial perfusion imaging agents: 99m-Tc-sestamibi and 99m-Tc-teboroxime, Circulation, 84, 17

Berman, 1991, Tc-99m sestamibi imaging in the assessment of chronic coronary artery disease, Semin Nucl Med, 21, 190, 10.1016/S0001-2998(05)80040-6

Friedman, 1991, Simultaneous dual isotope rest/stress myocardial perfusion scintigraphy. A feasibility study [abstract], J Am Coll Cardiol, 17, 390A, 10.1016/0735-1097(91)92524-P

Kiat, 1991, Simultaneous rest T1-201/stress Tc-99m sestamibi dual isotope myocardial perfusion SPECT: a pilot study [abstract], J Nucl Med, 32, 1006

Kiat, 1992, Quantitative assessment of photon spillover in simultaneous rest T1-201/stress Tc-99m sestamibi dual isotope myocardial perfusion SPECT [abstract], J Nucl Med, 33, 854

Maublant, 1992, Comparison between thallium-201 and technetium-99m methoxyisobutyl isonitrile defect size in single-photon emission computed tomography at rest, exercise and redistribution in coronary artery disease, Am J Cardiol, 69, 183, 10.1016/0002-9149(92)91302-K

Diamond, 1979, Analysis of probability as an aid to the clinical diagnosis of coronary artery disease, N Engl J Med, 300, 1350, 10.1056/NEJM197906143002402

Friedman, 1988, Patient motion in thallium-201 myocardial SPECT imaging: an easily identified frequent source of artifactual defect, Clin Nucl Med, 13, 321, 10.1097/00003072-198805000-00001

Okada, 1980, Improved diagnostic accuracy of thallium-201 stress test using multiple observers and criteria derived from intraobserver analysis of variance, Am J Cardiol, 46, 619, 10.1016/0002-9149(80)90512-3

Atwood, 1981, Agreement in human interpretation of analog thallium myocardial perfusion images, Circulation, 64, 601, 10.1161/01.CIR.64.3.601

Matzer, 1991, A new approach to the assessment of tomographic thallium-201 in patients with left bundle branch block, J Am Coll Cardiol, 17, 1309, 10.1016/S0735-1097(10)80141-X

Chouraqui, 1990, Quantitative exercise thallium-201 rotational tomography for evaluation of patients with prior myocardial infarction, Am J Cardiol, 66, 151, 10.1016/0002-9149(90)90579-P

Palmas, 1992, Quantitative assessment of transient ischemic dilation in separate acquisition dual isotope myocardial perfusion SPECT [abstract], Circulation, 86, 1

Rozanski, 1983, The declining specificity of exercise radionuclide ventriculography, N Engl J Med, 309, 518, 10.1056/NEJM198309013090902

Rozanski, 1987, The efficacy of cardiovascular nuclear medicine exercise studies, Semin Nucl Med, 17, 104, 10.1016/S0001-2998(87)80016-8

Van Train, 1990, Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: a multicenter trial, J Nucl Med, 31, 1168

Van Train, 1992, Quantitation of same day Tc-99m sestamibi myocardial SPECT: multicenter trial validation [abstract], J Nucl Med, 33, 876

Maddahi, 1991, Assessment of myocardial perfusion by single-photon agents, 179

Berman, 1984, Thallium-201 myocardial perfusion scintigraphy, 479

Garcia, 1990, Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi, Am J Cardiol, 66, 23E, 10.1016/0002-9149(90)90608-4

Blood, 1981, Comparison of single-dose and double-dose thallium-201 myocardial perfusion scintigraphy for the detection of coronary artery disease and prior myocardial infarction, Circulation, 58, 777, 10.1161/01.CIR.58.5.777

Berger, 1979, Redistribution of thallium-201 at rest in patients with stable and unstable angina and the effect of coronary artery bypass surgery, Circulation, 60, 1114, 10.1161/01.CIR.60.5.1114

Iskandrian, 1983, Rest and redistribution thallium-201 myocardial scintigraphy to predict improvement in left ventricular function after coronary artery bypass grafting, Am J Cardiol, 51, 1312, 10.1016/0002-9149(83)90304-1

Mori, 1991, Rest-injected thallium-201 imaging for assessing viability of severe asynergic regions, J Nucl Med, 32, 1718

Gerwitz, 1979, Transient defects of rest thallium scans in patients with coronary artery disease, Circulation, 59, 707, 10.1161/01.CIR.59.4.707

Gutman, 1983, Time to completed redistribution of thallium-201 in exercise myocardial scintigraphy: relationship to the degree of coronary artery stenosis, Am Heart J, 106, 989, 10.1016/0002-8703(83)90642-7

Kiat, 1988, Late reversibility of tomographic myocardial thallium-201 defects: an accurate marker of myocardial viability, J Am Coll Cardiol, 12, 1456, 10.1016/S0735-1097(88)80009-3

Cloninger, 1988, Incomplete redistribution in delayed thallium-201 single photon emission computed tomographic (SPECT) images: an overestimation of myocardial scarring, J Am Coll Cardiol, 12, 955, 10.1016/0735-1097(88)90461-5

McCallister, 1992, The value of 24-hour images after rest thallium injection [abstract], J Am Coll Cardiol, 19, 128A

Kiat, 1993, Frequency of reversible resting hypoperfusion in patients undergoing rest T1-201/stress Tc-99m sestamibi separate acquisition dual isotope myocardial perfusion SPECT [abstract], J Am Coll Cardiol, 21, 222A

Taillefer, 1992, Comparison between early (15 minutes) and delayed (60 minutes) myocardial 99mTc-sestamibi SPECT imaging in detection of coronary artery disease [abstract], J Nucl Med, 33, 855

Franceschi, 1990, Myocardial clearance of Tc-99m-hexakis-2-methoxy-2-methylpropyl isonitrile (MIBI) in patients with coronary artery disease, Clin Nucl Med, 15, 307, 10.1097/00003072-199005000-00005

Taillefer, 1991, Technetium-99m sestamibi myocardial perfusion imaging in detection of coronary artery disease: comparison between initial (1-hour) and delayed (3-hour) postexercise images, J Nucl Med, 32, 1961

Wackers, 1989, Technetiun-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety and preliminary comparison to thallium-201 for myocardial perfusion imaging, J Nucl Med, 30, 301