Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: A clinical validation study
Tóm tắt
Từ khóa
Tài liệu tham khảo
Iskandrian, 1989, Use of technetium-99m isonitrile (RP-30A) in assessing left ventricular perfusion and function at rest and during exercise in coronary artery disease, and comparison with coronary arteriography and exercise thallium-201 SPECT imaging, Am J Cardiol, 64, 270, 10.1016/0002-9149(89)90518-3
Kahn, 1989, Quantitative rotational tomography with T1-201 and Tc-99m 2-methoxy-isobutyl-isonitrile: a direct comparison in normal individuals and patients with coronary artery disease, Circulation, 79, 1282, 10.1161/01.CIR.79.6.1282
Kiat, 1990, Development and prospective application of quantitative 2-day stress-rest Tc-99m methoxy isobutyl isonitrile SPECT for the diagnosis of coronary artery disease, Am Heart J, 120, 1255, 10.1016/0002-8703(90)90234-O
Berman, 1991, The new 99m-Tc myocardial perfusion imaging agents: 99m-Tc-sestamibi and 99m-Tc-teboroxime, Circulation, 84, 17
Berman, 1991, Tc-99m sestamibi imaging in the assessment of chronic coronary artery disease, Semin Nucl Med, 21, 190, 10.1016/S0001-2998(05)80040-6
Friedman, 1991, Simultaneous dual isotope rest/stress myocardial perfusion scintigraphy. A feasibility study [abstract], J Am Coll Cardiol, 17, 390A, 10.1016/0735-1097(91)92524-P
Kiat, 1991, Simultaneous rest T1-201/stress Tc-99m sestamibi dual isotope myocardial perfusion SPECT: a pilot study [abstract], J Nucl Med, 32, 1006
Kiat, 1992, Quantitative assessment of photon spillover in simultaneous rest T1-201/stress Tc-99m sestamibi dual isotope myocardial perfusion SPECT [abstract], J Nucl Med, 33, 854
Maublant, 1992, Comparison between thallium-201 and technetium-99m methoxyisobutyl isonitrile defect size in single-photon emission computed tomography at rest, exercise and redistribution in coronary artery disease, Am J Cardiol, 69, 183, 10.1016/0002-9149(92)91302-K
Diamond, 1979, Analysis of probability as an aid to the clinical diagnosis of coronary artery disease, N Engl J Med, 300, 1350, 10.1056/NEJM197906143002402
Friedman, 1988, Patient motion in thallium-201 myocardial SPECT imaging: an easily identified frequent source of artifactual defect, Clin Nucl Med, 13, 321, 10.1097/00003072-198805000-00001
Okada, 1980, Improved diagnostic accuracy of thallium-201 stress test using multiple observers and criteria derived from intraobserver analysis of variance, Am J Cardiol, 46, 619, 10.1016/0002-9149(80)90512-3
Atwood, 1981, Agreement in human interpretation of analog thallium myocardial perfusion images, Circulation, 64, 601, 10.1161/01.CIR.64.3.601
Matzer, 1991, A new approach to the assessment of tomographic thallium-201 in patients with left bundle branch block, J Am Coll Cardiol, 17, 1309, 10.1016/S0735-1097(10)80141-X
Chouraqui, 1990, Quantitative exercise thallium-201 rotational tomography for evaluation of patients with prior myocardial infarction, Am J Cardiol, 66, 151, 10.1016/0002-9149(90)90579-P
Palmas, 1992, Quantitative assessment of transient ischemic dilation in separate acquisition dual isotope myocardial perfusion SPECT [abstract], Circulation, 86, 1
Rozanski, 1983, The declining specificity of exercise radionuclide ventriculography, N Engl J Med, 309, 518, 10.1056/NEJM198309013090902
Rozanski, 1987, The efficacy of cardiovascular nuclear medicine exercise studies, Semin Nucl Med, 17, 104, 10.1016/S0001-2998(87)80016-8
Van Train, 1990, Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: a multicenter trial, J Nucl Med, 31, 1168
Van Train, 1992, Quantitation of same day Tc-99m sestamibi myocardial SPECT: multicenter trial validation [abstract], J Nucl Med, 33, 876
Maddahi, 1991, Assessment of myocardial perfusion by single-photon agents, 179
Berman, 1984, Thallium-201 myocardial perfusion scintigraphy, 479
Garcia, 1990, Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi, Am J Cardiol, 66, 23E, 10.1016/0002-9149(90)90608-4
Blood, 1981, Comparison of single-dose and double-dose thallium-201 myocardial perfusion scintigraphy for the detection of coronary artery disease and prior myocardial infarction, Circulation, 58, 777, 10.1161/01.CIR.58.5.777
Berger, 1979, Redistribution of thallium-201 at rest in patients with stable and unstable angina and the effect of coronary artery bypass surgery, Circulation, 60, 1114, 10.1161/01.CIR.60.5.1114
Iskandrian, 1983, Rest and redistribution thallium-201 myocardial scintigraphy to predict improvement in left ventricular function after coronary artery bypass grafting, Am J Cardiol, 51, 1312, 10.1016/0002-9149(83)90304-1
Mori, 1991, Rest-injected thallium-201 imaging for assessing viability of severe asynergic regions, J Nucl Med, 32, 1718
Gerwitz, 1979, Transient defects of rest thallium scans in patients with coronary artery disease, Circulation, 59, 707, 10.1161/01.CIR.59.4.707
Gutman, 1983, Time to completed redistribution of thallium-201 in exercise myocardial scintigraphy: relationship to the degree of coronary artery stenosis, Am Heart J, 106, 989, 10.1016/0002-8703(83)90642-7
Kiat, 1988, Late reversibility of tomographic myocardial thallium-201 defects: an accurate marker of myocardial viability, J Am Coll Cardiol, 12, 1456, 10.1016/S0735-1097(88)80009-3
Cloninger, 1988, Incomplete redistribution in delayed thallium-201 single photon emission computed tomographic (SPECT) images: an overestimation of myocardial scarring, J Am Coll Cardiol, 12, 955, 10.1016/0735-1097(88)90461-5
McCallister, 1992, The value of 24-hour images after rest thallium injection [abstract], J Am Coll Cardiol, 19, 128A
Kiat, 1993, Frequency of reversible resting hypoperfusion in patients undergoing rest T1-201/stress Tc-99m sestamibi separate acquisition dual isotope myocardial perfusion SPECT [abstract], J Am Coll Cardiol, 21, 222A
Taillefer, 1992, Comparison between early (15 minutes) and delayed (60 minutes) myocardial 99mTc-sestamibi SPECT imaging in detection of coronary artery disease [abstract], J Nucl Med, 33, 855
Franceschi, 1990, Myocardial clearance of Tc-99m-hexakis-2-methoxy-2-methylpropyl isonitrile (MIBI) in patients with coronary artery disease, Clin Nucl Med, 15, 307, 10.1097/00003072-199005000-00005
Taillefer, 1991, Technetium-99m sestamibi myocardial perfusion imaging in detection of coronary artery disease: comparison between initial (1-hour) and delayed (3-hour) postexercise images, J Nucl Med, 32, 1961
Wackers, 1989, Technetiun-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety and preliminary comparison to thallium-201 for myocardial perfusion imaging, J Nucl Med, 30, 301