Sensitive and rapid high-performance liquid chromatographic method for simultaneous determination of antidepressants in pharmaceutical formulations
Tóm tắt
An easy, rapid, and sensitive high-performance liquid chromatographic (HPLC) method is proposed for simultaneous determination of five antidepressants (trazodone, citalopram, fluoxetine, fluvoxamine and clomipramine) and norfluoxetine, a major metabolite of fluoxetine. Optimum conditions for the quantitative separation were investigated. The compounds were separated on a Nova Pack C18 column with acetonitrile-pH 2.5 phosphate buffer, 40∶60 (v/v), as mobile phase at a flow rate of 1.5 mL min−1. Stability of solutions, linearity, repeatability and reproducibility, accuracy, specificity, and detection and quantification limits were examined to validate the method. The method is rapid and sensitive and can be applied to the analysis of antidepressants in pharmaceutical formulations and biological fluids; norfluoxetine can also be determined in these matrices. We have tested the method by analysis of several pharmaceutical formations; recoveries obtained were between 102.7% and 98.2% of the labelled values.
Từ khóa
Tài liệu tham khảo
Berzas, J.J.; Villaseñor, M.J.; Contento, A.M.; Aguas, E.J. Chromatogr. Sci. 2000,38, 200.
Holister, L.E.Drugs 1981,22, 129.
Dugas, M.; Zarifian, E.; Leheuzey, M.F.; Rovei, V.; Durand, G.; Morselli, P.L.Ther. Drug Monit. 1980,2, 307.
Kasper, S.; Höflich, G.; Scholl, H.P.; Möller, H.J.Hum. Psychopharmacol. 1994,9, 1.
Preskorn, S.H.J. Clin. Psychiatry 1994,55(Suppl. A), 6.
Lautz, R.I.; Farid, J.; Koons, K.Z.; Tenbargue, J.B.; Bopp, R.I.J. Chromatogr. B. Biomed. Appl. 1993,614(1), 175–179.
Eap, C.B.; Gaillard, N.; Powell, K.; Baumann, P.J. Chromatogr. B. Biomed. Appl. 1996,682(2), 265–272.
Eap, C.B.; Bouchoux, G.; Amey, M.; Cochard, N.; Savary, L.; Baumann, P.J. Chromatogr. Sci. 1998,36.
Meineke, I.; Schreeb, K.; Kress, I.; Gundert-Remy, U.Ther. Drug Monit. 1998,20(1), 14–19.
Pichini, S.; Pacifini, R.; Altieri, I.; Pellegrini, M.; Zuccaro, P.J.Liq. Chromatogr. Related Technol. 1996,19(12), 1927–1935.
Torok-Both, G.A.; Baker, G.B.; Coutts, R.T.; Mackenna, K.F.; Aspeslet, L.I.J. Chromatogr. Biomed. Appl. 1992,579(1), 99–106.
Alvarez, J.C.; Bothua, D.; Collignon, I.; Advenier, C.; Spreux-Varoquaux, O.J. Chromatogr. B. Biomed. Appl. 1998,707(1/2), 175–180.
Wong, S.H.Y.; Dellafera, S.S.; Fernandes, R.; Kranzler, H.J. Chromatogr. 1990,499, 601.
Raggi, M.A.; Mandrioli, R.; Casamenti, G.; Bugamelli, F.; Volterra, V.J. Pharm. Biomed. Anal. 1998,18(1/2), 193–199.
Raggi, M.A.; Mandrioli, R.; Casamenti, G.; Volterra, V.; Desiderio, C.; Fanali, S.Chromatographia 1999,50(7/8), 423–427.
Aymard, G.; Livi, P.; Pham, Y.T.; Diquet, B.J. Chromatogr. B 1997,700, 183.
Kristoffersen, L.; Bugge, A.; Lundanes, E.; Slordal, L.J. Chromatography B 1999,734, 229.
Lacassie, E.; Gaulier, J.M.; Marquet, P.; Rabatel, J.F.; Lachatre, G.J. Chromatogr. B 2000,742, 229.
Berzas, J.J.; Contento, A.M.; Villaseñor, M.J.; Aguas, E.Anal. Chim. Acta 2000,417, 169.
Desiderio, C.; Rudaz, S.; Raggli, M.A.; Fanali, S.Electrophoresis 1999,20(17), 3432.
Berzas, J.J.; Contento, A.M.Chromatographia 2002,55, 369–373.
Goodnough, D.B.; Baker, G.B.; Coutts, R.T.J. Pharmacol. Toxicol. Methods 1995,34, 143.
Berzas, J.J.; Contento, A.M.; Villaseñor, M.J.J. Chromatogr. B. 2002,769, 261–268.
Storch de Gracia, J.J.; Ed. Alhambra,1987, pp. 122.
Lark, P.D.; Craven, B.R.; Bosworth, R.C.L.The Handling of Chemical Data, Pergamon Press, Oxford,1968, Chapter 4, pp. 136–206.
Massart, D.L.; Vandeginste, B.G.M.; Deming, S.N.; Kaufmann, L. In:Chemometrics: A Textbook, 1st edn, Vandeginste, B.G.M.; Kaufmann, L., Eds, Oxford University Press, Oxford,1988.
Fabre, H.; Le Bris, A.; Balchin, M.D.J. Chromatogr. A 1995,697, 81.
Huber, L.Applications of Diode-Array Experience, Hewlett-Packard Publication no. 12-5953-2330,1989.