Results of proximal humeral locked plating with supplemental suture fixation of rotator cuff

Journal of Shoulder and Elbow Surgery - Tập 20 - Trang 616-624 - 2011
Brian Badman1, Mark Frankle2, Christopher Keating3, Leanne Henderson2, Jordan Brooks3, Mark Mighell2
1UAP Bone and Joint Union Hospital, Terre Haute, IN, USA
2Florida Orthopaedic Institute, Tampa, FL, USA
3Foundation for Orthopaedic Research and Education, Tampa, FL, USA

Tài liệu tham khảo

Badman, 2008, Fixed-angle locked plating of two-, three-, and four-part proximal humerus fractures, J Am Acad Orthop Surg, 16, 294, 10.5435/00124635-200805000-00008 Bigorre, 2009, A prospective study of a new locking plate for proximal humeral fracture, Injury, 40, 192, 10.1016/j.injury.2008.06.023 Cuomo, 1992, Open reduction and internal fixation of two- and three-part displaced surgical neck fractures of the proximal humerus. Journal of shoulder and elbow surgery, Am Shoulder Elbow Surg, 1, 287, 10.1016/S1058-2746(09)80055-4 Darder, 1993, Four-part displaced proximal humeral fractures: operative treatment using Kirschner wires and a tension band, J Orthop Trauma, 7, 497, 10.1097/00005131-199312000-00002 Depalma, 1961, Fractures of the upper end of the humerus, Clin Orthop, 20, 73 Dimakopoulos, 2009, Transosseous suture fixation of proximal humeral fractures. Surgical technique, J Bone Joint Surg Am, 91, 8, 10.2106/JBJS.H.01290 Duralde, 2010, The results of ORIF of displaced unstable proximal humeral fractures using a locking plate, J Shoulder Elbow Surg, 19, 480, 10.1016/j.jse.2009.08.008 Egol, 2008, Early complications in proximal humerus fractures (OTA Types 11) treated with locked plates, J Orthop Trauma, 22, 159, 10.1097/BOT.0b013e318169ef2a Esser, 1994, Treatment of three- and four-part fractures of the proximal humerus with a modified cloverleaf plate, J Orthop Trauma, 8, 15, 10.1097/00005131-199402000-00005 Gardner, 2008, Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant, J Orthop Trauma, 22, 195, 10.1097/BOT.0b013e31815b3922 Gardner, 2007, The importance of medial support in locked plating of proximal humerus fractures, J Orthop Trauma, 21, 185, 10.1097/BOT.0b013e3180333094 Goldman, 1995, Functional outcome after humeral head replacement for acute three- and four-part proximal humeral fractures, J Shoulder Elbow Surg, 4, 81, 10.1016/S1058-2746(05)80059-X Hawkins, 1986, The three-part fracture of the proximal part of the humerus. Operative treatment, J Bone Joint Surg Am, 68, 1410, 10.2106/00004623-198668090-00014 Hertel, 2004, Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus, J Shoulder Elbow Surg, 13, 427, 10.1016/j.jse.2004.01.034 Jaberg, 1992, Percutaneous stabilization of unstable fractures of the humerus, J Bone Joint Surg Am, 74, 508, 10.2106/00004623-199274040-00006 Jakob, 1991, Four-part valgus impacted fractures of the proximal humerus, J Bone Joint Surg Br, 73, 295, 10.1302/0301-620X.73B2.2005159 Kristiansen, 1986, Plate fixation of proximal humeral fractures, Acta Orthop Scand, 57, 320, 10.3109/17453678608994401 Lee, 1981, Post-traumatic avascular necrosis of the humeral head in displaced proximal humeral fractures, J Trauma, 21, 788, 10.1097/00005373-198109000-00006 Lo, 2002, Biomechanical principles of arthroscopic repair of the rotator cuff, Op Tech Orthop, 12, 140, 10.1053/otor.2002.36297 Moeckel, 1992, Modular hemiarthroplasty for fractures of the proximal part of the humerus, J Bone Joint Surg Am, 74, 884, 10.2106/00004623-199274060-00009 Moonot, 2007, Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system, J Bone Joint Surg Br, 89, 1206, 10.1302/0301-620X.89B9.18528 Mouradian, 1986, Displaced proximal humeral fractures. Seven years’ experience with a modified Zickel supracondylar device, Clin Orthop Relat Res, 209 Nayak, 1995, Operative treatment of nonunion of surgical neck fractures of the humerus, Clin Orthop Relat Res, 200 Neer, 1970, Displaced proximal humeral fractures. I. Classification and evaluation, J Bone Joint Surg Am, 52, 1077, 10.2106/00004623-197052060-00001 Neer, 1970, Displaced proximal humeral fractures. II. Treatment of three-part and four-part displacement, J Bone Joint Surg Am, 52, 1090, 10.2106/00004623-197052060-00002 Norris, 1995, Late prosthetic shoulder arthroplasty for displaced proximal humerus fractures, J Shoulder Elbow Surg, 4, 271, 10.1016/S1058-2746(05)80020-5 Owsley, 2008, Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected], J Bone Joint Surg Am, 90, 233, 10.2106/JBJS.F.01351 Paavolainen, 1983, Operative treatment of severe proximal humeral fractures, Acta Orthop Scand, 54, 374, 10.3109/17453678308996587 Park, 2003, Two-part and three-part fractures of the proximal humerus treated with suture fixation, J Orthop Trauma, 17, 319, 10.1097/00005131-200305000-00001 Richards, 1994, A standardized method for the assessment of shoulder function, J Shoulder Elbow Surg, 3, 347, 10.1016/S1058-2746(09)80019-0 Rose, 2007, Locking plate fixation for proximal humeral fractures: initial results with a new implant, J Shoulder Elbow Surg, 16, 202, 10.1016/j.jse.2006.06.006 Sanders, 2007, Biomechanical evaluation of locked plating in proximal humeral fractures, J Shoulder Elbow Surg, 16, 229, 10.1016/j.jse.2006.03.013 Savoie, 1989, Open reduction and internal fixation of three-part fractures of the proximal humerus, Orthopedics, 12, 65, 10.3928/0147-7447-19890101-09 Shrader, 2005, Understanding proximal humerus fractures: image analysis, classification, and treatment, J Shoulder Elbow Surg, 14, 497, 10.1016/j.jse.2005.02.014 Siffri, 2006, Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri, J Orthop Trauma, 20, 547, 10.1097/01.bot.0000244997.52751.58 Solberg, 2009, Locked plating of 3- and 4-part proximal humerus fractures in older patients: the effect of initial fracture pattern on outcome, J Orthop Trauma, 23, 113, 10.1097/BOT.0b013e31819344bf Sporer, 2006, The geographic incidence and treatment variation of common fractures of elderly patients, J Am Acad Orthop Surg, 14, 246, 10.5435/00124635-200604000-00006 Stableforth, 1984, Four-part fractures of the neck of the humerus, J Bone Joint Surg Br, 66, 104, 10.1302/0301-620X.66B1.6693466 Sturzenegger, 1982, Results of surgical treatment of multifragmented fractures of the humeral head, Arch Orthop Trauma Surg, 100, 249, 10.1007/BF00381665 Swan, 2009, Arthroscopic suture material and knot type: an updated biomechanical analysis, Am J Sports Med, 37, 1578, 10.1177/0363546509332816 Szyszkowitz, 1993, Proximal humeral fractures. Management techniques and expected results, Clin Orthop Relat Res, 13, 10.1097/00003086-199307000-00005 Tanner, 1983, Prosthetic arthroplasty for fractures and fracture-dislocations of the proximal humerus, Clin Orthop Relat Res, 116 Thanasas, 2009, Treatment of proximal humerus fractures with locking plates: a systematic review, J Shoulder Elbow Surg, 18, 837, 10.1016/j.jse.2009.06.004 Volgas, 2004, Nonunions of the humerus, Clin Orthop Relat Res, 46, 10.1097/00003086-200402000-00008 Weseley, 1977, Rush pin intramedullary fixation for fractures of the proximal humerus, J Trauma, 17, 29, 10.1097/00005373-197701000-00004