Quantity and Location of Aortic Valve Complex Calcification Predicts Severity and Location of Paravalvular Regurgitation and Frequency of Post-Dilation After Balloon-Expandable Transcatheter Aortic Valve Replacement

JACC: Cardiovascular Interventions - Tập 7 - Trang 885-894 - 2014
Omar K. Khalique1, Rebecca T. Hahn1, Hemal Gada1, Tamim M. Nazif1, Torsten P. Vahl1, Isaac George2, Bindu Kalesan1, Molly Forster1, Mathew B. Williams1, Martin B. Leon1, Andrew J. Einstein1, Todd C. Pulerwitz2, Gregory D.N. Pearson1, Susheel K. Kodali1
1Columbia University Medical Center/New York Presbyterian Hospital, New York, New York
2Columbia University Medical Center/New York-Presbyterian Hospital, New York, New York

Tài liệu tham khảo

Smith, 2011, Transcatheter versus surgical aortic-valve replacement in high-risk patients, N Engl J Med, 364, 2187, 10.1056/NEJMoa1103510

Leon, 2010, Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery, N Engl J Med, 363, 1597, 10.1056/NEJMoa1008232

Makkar, 2012, Transcatheter aortic-valve replacement for inoperable severe aortic stenosis, N Engl J Med, 366, 1696, 10.1056/NEJMoa1202277

Athappan, 2013, Incidence, predictors and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature, J Am Coll Cardiol, 61, 1585, 10.1016/j.jacc.2013.01.047

Abdel-Wahab, 2011, Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German Transcatheter Aortic Valve Interventions Registry, Heart, 97, 899, 10.1136/hrt.2010.217158

Tamburino, 2011, Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis, Circulation, 123, 299, 10.1161/CIRCULATIONAHA.110.946533

Kodali, 2012, Two-year outcomes after transcatheter or surgical aortic-valve replacement, N Engl J Med, 366, 1686, 10.1056/NEJMoa1200384

Haensig, 2012, Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation, Eur J Cardiothorac Surg, 41, 1234, 10.1093/ejcts/ezr244

Leber, 2013, Aortic valve calcium score as a predictor for outcome after TAVI using the CoreValve revalving system, Int J Cardiol, 166, 652, 10.1016/j.ijcard.2011.11.091

Santos, 2012, Prosthesis/annulus discongruence assessed by three-dimensional transoesophageal echocardiography: a predictor of significant paravalvular aortic regurgitation after transcatheter aortic valve implantation, Eur Heart J Cardiovasc Imaging, 13, 931, 10.1093/ehjci/jes072

Hahn, 2013, Predicting paravalvular regurgitation following transcatheter valve replacement: utility of a novel method for three-dimensional echocardiographic measurements of the aortic annulus, J Am Soc Echocardiogr, 26, 1043, 10.1016/j.echo.2013.07.004

Khalique, 2014, Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography, Circ Cardiovasc Imaging, 7, 155, 10.1161/CIRCIMAGING.113.001153

Glodny, 2009, A method for calcium quantification by means of CT coronary angiography using 64-multidetector CT: very high correlation with Agatston and volume scores, Eur Radiol, 19, 1661, 10.1007/s00330-009-1345-2

Fang, 2005, Assessment of aortic regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area: usefulness and validation, Echocardiography, 22, 775, 10.1111/j.1540-8175.2005.00171.x

Goncalves, 2012, Three-dimensional echocardiography in paravalvular aortic regurgitation assessment after transcatheter aortic valve implantation, J Am Soc Echocardiogr, 25, 47, 10.1016/j.echo.2011.08.019

Wood, 2009, Role of multislice computed tomography in transcatheter aortic valve replacement, Am J Cardiol, 103, 1295, 10.1016/j.amjcard.2009.01.034

Gripari, 2012, Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation, Heart, 98, 1229, 10.1136/heartjnl-2012-301998

Schultz, 2011, Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis, EuroIntervention, 7, 564, 10.4244/EIJV7I5A92