Proprioception in the ACL-ruptured knee: The contribution of the medial collateral ligament and patellar ligament. An in vivo experimental study in the cat

The Knee - Tập 14 - Trang 39-45 - 2007
N. Bonsfills1, J.J. Raygoza2, E. Boemo2, J. Garrido2, A. Núñez3, E. Gómez-Barrena4
1Unidad de Ortopedia Pediátrica, Hospital Universitario La Paz (Hospital Infantil), Paseo de la Castellana, 261, 28046 — Madrid, Spain
2Escuela Politécnica Superior, Universidad Autónoma de Madrid, Spain
3Departamento de Morfología, Facultad de Medicina, Universidad Autónoma de Madrid Spain
4Departamento de Cirugía, Facultad de Medicina, Universidad Autónoma de Madrid, Spain

Tài liệu tham khảo

McCarty, 2003, Ligament cutting studies, 81

Gómez-Barrena, 1997, Neural and muscular electric activity in the cat's knee, Acta Orthop Scand, 68, 149, 10.3109/17453679709003998

Crisco, 2002, Strain-rate sensitivity of the rabbit MCL diminishes at traumatic loading rates, J Biomech, 35, 1379, 10.1016/S0021-9290(02)00167-7

Daniel, 1993

Maitland, 1998, Method to assess in vivo knee stability longitudinally in an animal model of ligament injury, J Orthop Res, 16, 441, 10.1002/jor.1100160408

Ageberg, 2002, Consequences of a ligament injury on neuromuscular function and relevance to rehabilitation — using the anterior cruciate ligament-injured knee as model, J. Electromyogr. Kinesiol., 12, 205, 10.1016/S1050-6411(02)00022-6

Holden, 1995, Factors affecting sensitivity of a transducer for measuring anterior cruciate ligament force, J Biomech, 28, 99, 10.1016/0021-9290(95)80011-5

Fleming, 1994, Determination of a zero strain reference for the anteromedial band of the anterior cruciate ligament, J Orthop Res, 12, 789, 10.1002/jor.1100120606

Beynnon, 2002, The science of anterior cruciate ligament rehabilitation, Clin Orthop, 402, 9, 10.1097/00003086-200209000-00003

Cholewicki, 1997, Spinal ligament transducer based on a Hall effect sensor, J Biomech, 30, 291, 10.1016/S0021-9290(96)00137-6

Herzog, 1996, Evaluation of the implantable force transducer for chronic tendon-force recordings, J Biomech, 29, 103, 10.1016/0021-9290(95)00019-4

Biewener, 2001, Dynamics of mallard (Anas platyrhynchos) gastrocnemius function during swimming versus terrestrial locomotion, J Exp Biol, 204, 1745, 10.1242/jeb.204.10.1745

Williamson, 2001, Pectoralis muscle performance during ascending and slow level flight in mallards (Anas platyrhynchos), J Exp Biol, 204, 495, 10.1242/jeb.204.3.495

Hinterwimmer, 2002, Tension changes in the collateral ligaments of a cruciate ligament-deficient knee joint: an experimental biomechanical study, Arch Orthop Trauma Surg, 122, 454, 10.1007/s00402-002-0432-5

Wojtys, 1994, Neuromuscular performance in normal and anterior cruciate ligament-deficient lower extremities, Am. J. Sports Med., 22, 89, 10.1177/036354659402200116

Beard, 1993, Proprioception after rupture of the anterior cruciate ligament. An objective indication of the need of surgery?, J Bone Jt Surg, 75-B, 311, 10.1302/0301-620X.75B2.8444956

Jennings, 1994, Proprioception in the knee and reflex hamstring contraction latency, J Bone Jt Surg, 76-B, 491, 10.1302/0301-620X.76B3.8175863

Solomonow, 1987, The synergistic action of the anterior cruciate ligament and thigh muscles in maintaining joint stability, Am. J. Sports Med., 15, 207, 10.1177/036354658701500302

Gómez-Barrena, 1996, Segmental sensory innervation of the anterior cruciate ligament and the patellar tendon of the cat's knee, Acta Orthop Scand, 67, 545, 10.3109/17453679608997753

Beynnon, 1998, Anterior cruciate ligament strain in vivo: a review of previous work, J Biomech, 31, 519, 10.1016/S0021-9290(98)00044-X

Markolf, 1998, In situ calibration of miniature sensors implanted into the anterior cruciate ligament Part I: Strain measurements, J Orthop Res, 16, 455, 10.1002/jor.1100160410

Markolf, 1998, In situ calibration of miniature sensors implanted into the anterior cruciate ligament Part II: Force probe measurements, J Orthop Res, 16, 464, 10.1002/jor.1100160411

Hinterwimmer, 2003, Strain measurement at the knee ligament insertion sites, Biomed Tech (Berl), 48, 11, 10.1515/bmte.2003.48.1-2.11

Fujita, 2000, Characterization of hamstrings reflexes during anterior cruciate ligament disruption: in vivo results from a goat model, J. Orthop. Res., 18, 183, 10.1002/jor.1100180204

Enoka, 2002, Describing motion, 6

Raygoza-Panduro, 2004, FPGAs implementation of digital electronic circuit to pattern clasification of knee instability