Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection Fraction

New England Journal of Medicine - Tập 346 Số 12 - Trang 877-883 - 2002
Arthur J. Moss1, Wojciech Zaręba2, William J. Hall3, Helmut Klein4, David J. Wilber5, David S. Cannom6, James P. Daubert, Steven L. Higgins7, Mary W. Brown2, Mark Andrews2
1Cardiology Unit of the Department of Medicine, University of Rochester Medical Center, Rochester, NY, USA. [email protected]
2Cardiology Unit of the Department of Medicine, University of Rochester Medical Center, Rochester, N.Y.
3Department of Biostatistics, University of Rochester Medical Center, Rochester, N.Y.
4Division of Cardiology, University Hospital, Magdeburg, Germany
5Cardiology Unit, Loyola University Medical Center, Maywood, Ill.
6Cardiology Associates, Good Samaritan Hospital, Los Angeles
7Department of Cardiology, Scripps Memorial Hospital, La Jolla, Calif.

Tóm tắt

Từ khóa


Tài liệu tham khảo

10.1056/NEJM199612263352601

10.1056/NEJM199912163412503

10.1056/NEJM200006293422602

10.1056/NEJM198904063201432

10.1111/j.1542-474X.1999.tb00369.x

Whitehead J. The design and analysis of sequential clinical trials. Rev. 2nd ed. Chichester, England: John Wiley, 1997.

Cox DR, 1972, J R Stat Soc [B], 34, 187

10.2307/2281868

10.1056/NEJM199711273372202

10.1016/S0735-1097(99)00194-1

10.1016/0002-9149(90)90025-V

Cohn JN, 1997, Circulation, 95, 766, 10.1161/01.CIR.95.4.766

10.1046/j.1540-8167.2001.00369.x