Modeling of insulin secretion and insulin mass balance during hemodialysis in patients with and without type 2 diabetes

Biocybernetics and Biomedical Engineering - Tập 41 Số 2 - Trang 391-401 - 2021
Daniel Schneditz1, Longin Niemczyk2, Stanisław Niemczyk3
1Otto Loewi Research Center, Div. of Physiology, Medical University of Graz, Graz, Austria
2Dept. of Nephrology, Dialysis and Internal Diseases, Medical University of Warsaw, Warsaw, Poland
3Dept. of Internal Diseases, Nephrology and Dialysis, Military Institute of Medicine, Warsaw, Poland

Tóm tắt

Từ khóa


Tài liệu tham khảo

Palumbo, 2013, Mathematical modeling of the glucose-insulin system: a review, Math Biosci, 244, 69, 10.1016/j.mbs.2013.05.006

Yarragudi, 2019, New-onset diabetes mellitus in peritoneal dialysis and hemodialysis patients: frequency, risk factors, and prognosis-a review, Ther Apher Dial, 23, 497, 10.1111/1744-9987.12800

Ritz, 1999, End-stage renal failure in type 2 diabetes: A medical catastrophe of worldwide dimensions, Am J Kidney Dis, 34, 795, 10.1016/S0272-6386(99)70035-1

Iyengar, 2018, Inpatient glycemic management in the setting of renal insufficiency/failure/dialysis, Curr Diab Rep, 18, 75, 10.1007/s11892-018-1044-y

Schneditz, 2010, Intracorporeal glucose disposal during hemodialysis after a standardized glucose load, ASAIO J, 56, 204, 10.1097/MAT.0b013e3181ce1c9b

Niemczyk, 2021, Glucose tolerance in patients with and without type 2 diabetes mellitus during hemodialysis, Diabetes Res Clin Pr, 173, 108694, 10.1016/j.diabres.2021.108694

Roth, 2012, Infrared spectroscopy in hemodialysis: reagent-free monitoring of patient detoxification by infrared spectroscopy, Anal Bioanal Chem, 403, 391, 10.1007/s00216-012-5880-3

DeFronzo, 1981, Insulin resistance in uremia, J Clin Invest, 67, 563, 10.1172/JCI110067

Oshida, 1987, Studies on glucose intolerance in chronic renal failure: estimation of insulin sensitivity before and after initiation of hemodialysis, Clin Nephrol, 28, 35

Mak, 1992, Glucose and insulin metabolism in uremia, Nephron, 61, 377, 10.1159/000186953

Abe, 2007, Plasma insulin is removed by hemodialysis: evaluation of the relation between plasma insulin and glucose by using a dialysate with or without glucose, Ther Apher Dial, 11, 280, 10.1111/j.1744-9987.2007.00491.x

Jorgensen, 2015, Clearance of glucoregulatory peptide hormones during haemodialysis and haemodiafiltration in non-diabetic end-stage renal disease patients, Nephrol Dial Transplant, 30, 513, 10.1093/ndt/gfu327

Knopp, 2019, Insulin units and conversion factors: a story of truth, boots, and faster half-truths, J Diabetes Sci Technol, 13, 597, 10.1177/1932296818805074

Singh, 2010, Surrogate markers of insulin resistance: A review, World J Diabetes, 1, 36, 10.4239/wjd.v1.i2.36

Schneditz, 1993, A regional blood circulation alternative to in-series two compartment urea kinetic modeling, ASAIO J, 39, M573

Schneditz, 2013, A regional blood flow model for glucose and insulin kinetics during hemodialysis, ASAIO J, 13, 627, 10.1097/MAT.0000436714.72752.13

Steele, 1956, Measurement of size and turnover rate of body glucose pool by the isotope dilution method, Am J Physiol, 187, 15, 10.1152/ajplegacy.1956.187.1.15

Mari, 2011, Relationship between glucose volume of distribution and the extracellular space: a multiple tracer study, Metabolism, 60, 1627, 10.1016/j.metabol.2011.03.017

Caumo A, Simeoni M, Cobelli C. Glucose modelling. In: Modelling methodology for physiology and Medicine, edited by Carson ECobelli C. San Diego, CA: Academic Press, 2001; 337-72

Mari, 2003, A circulatory model for calculating non-steady-state glucose fluxes. Validation and comparison with compartmental models, Comput Meth Programs Biomed, 71, 269, 10.1016/S0169-2607(02)00097-4

Toffollo GM, Cobelli C. Insulin modelling. In: Modelling Methodology for Physiology and Medinine, edited by Carson ECobelli C. San Diego, CA: Academic Press, 2001.

van der Sande, 2020, Using bioimpedance spectroscopy to assess volume status in dialysis patients, Blood Purif, 49, 178, 10.1159/000504079

Moissl, 2006, Body fluid volume determination via body composition spectroscopy in health and disease, Physiol Meas, 27, 921, 10.1088/0967-3334/27/9/012

Eaton, 1983, Hepatic removal of insulin in normal man: dose response to endogenous insulin secretion, J Clin Endocrinol Metab, 56, 1294, 10.1210/jcem-56-6-1294

Polonsky, 1986, Current approaches to measurement of insulin secretion, Diabetes Metab Rev, 2, 315, 10.1002/dmr.5610020306

Polonsky, 1988, Quantitative study of insulin secretion and clearance in normal and obese subjects, J Clin Invest, 81, 435, 10.1172/JCI113338

Saccomani MP, D'Angio' L, Audoly S, Cobelli C. A priori identifiability of physiological parametric models. In: Modelling Methodology for Physiology and Medicine, edited by Carson ECobelli C. San Diego, CA: Academic Press, 2001.

Cobelli, 2007, Assessment of beta-cell function in humans, simultaneously with insulin sensitivity and hepatic extraction, from intravenous and oral glucose tests, Am J Physiol Endocrinol Metab, 293, E1, 10.1152/ajpendo.00421.2006

Eaton, 1980, Prehepatic insulin production in man: kinetic analysis using peripheral connecting peptide behavior, J Clin Endocrinol Metab, 51, 520, 10.1210/jcem-51-3-520

Toffolo, 1995, Estimation of β-cell sensitivity from intravenous glucose tolerance test C-peptide data: knowledge of the kinetics avoids errors in modeling the secretion, Diabetes, 44, 845, 10.2337/diab.44.7.845