Microfluidic device and system for point-of-care blood coagulation measurement based on electrical impedance sensing
Tài liệu tham khảo
Ferraris, 2007, Perioperative blood transfusion and blood conservation in cardiac surgery: the society of thoracic surgeons and the society of cardiovascular anesthesiologists clinical practice guideline, Annals of Thoracic Surgery, 83, 27, 10.1016/j.athoracsur.2007.02.099
Yang, 2004, Home prothrombin time monitoring: a literature analysis, American Journal of Hematology, 77, 177, 10.1002/ajh.20161
Greer, 2008
Davie, 2003, JBC Centennial 1905–2005 – 100 years of biochemistry and molecular biology – a brief historical review of the waterfall/cascade of blood coagulation, Journal of Biological Chemistry, 278, 50819, 10.1074/jbc.X300009200
Schenone, 2004, The blood coagulation cascade, Current Opinion in Hematology, 11, 272, 10.1097/01.moh.0000130308.37353.d4
Langdell, 1953, Effect of anti-hemophilic factor on one-stage clotting tests; a presumptive test for hemophilia and a simple one-stage anti-hemophilic factor assay procedure, Journal of Laboratory and Clinical Medicine, 41, 637
White, 2003, The partial thromboplastin time: defining an era in coagulation, Journal of Thrombosis and Haemostasis, 1, 2267, 10.1046/j.1538-7836.2003.00459.x
Zucker, 1969, Control of heparin therapy. Sensitivity of activated partial thromboplastin time for monitoring antithrombotic effects of heparin, Journal of Laboratory and Clinical Medicine, 73, 320
Brandt, 1981, Laboratory monitoring of heparin. Effect of reagents and instruments in the activated partial thromboplastin time, American Journal of Clinical Pathology, 76
Carpenter, 1994, Overview of a novel point of care instrument system for measuring whole blood prothrombin time, Proceedings of the Society of Photo-Optical Instrumentation Engineering, 2136, 205
Metref, 2009, Microfluidic system based on thermal expandable polymer for on chip blood coagulation testing, Micro and Nanosystems, 1, 41, 10.2174/1876402910901010041
Puckett, 2003, Monitoring blood coagulation with magnetoelastic sensors, Biosensors & Bioelectronics, 18, 675, 10.1016/S0956-5663(03)00033-2
Andersson, 2005, Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces, Biosensors & Bioelectronics, 21, 79, 10.1016/j.bios.2004.09.026
Rosenthal, 1948, Measurement of the electrical resistance of human blood used in coagulation studies and cell volume determinations, Journal of Laboratory and Clinical Medicine, 33, 1110
Ur, 1970, Changes in the electrical impedance of blood during coagulation, Nature, 226, 269, 10.1038/226269a0
Gavin, 1997, Portable prothrombin time test apparatus and associated method of performing a prothrombin time test
Song, 2006, On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system, Analytical Chemistry, 78, 4839, 10.1021/ac0601718
Carville, 1998, Coagulation testing. Part 1. Current methods and challenges, IVD Technology, 4, 59
Carville, 1998, Coagulation testing. Part 2. The quest to optimize near-patient analyzers, IVD Technology, 4, 33
Tsakeris, 1999, Point-of-care I.V.Ds: overcoming the hurdles to market, IVD Technology, 5, 22
Zhao, 1996, New applications of electrical impedance of human blood, Journal of Medical Engineering & Technology, 20, 115, 10.3109/03091909609008389
Cha, 1994, A new bioelectrical impedance method for measurement of the erythrocyte sedimentation rate, Physiological Measurement, 15, 499, 10.1088/0967-3334/15/4/011
Cha, 1994, An electronic method for rapid measurement of haematocrit in blood samples, Physiological Measurement, 15, 129, 10.1088/0967-3334/15/2/003
Ur, 1977, Analysis and interpretation of the impedance blood coagulation curve, American Journal of Clinical Pathology, 67, 470, 10.1093/ajcp/67.5.470
Wilson, 1907, The conductivity of blood in coagulation, Biochemical Journal, 2, 377, 10.1042/bj0020377
Connelly, 1975, The continuous measurement of resistivity and permittivity of human blood plasma during coagulation, Medical & Biological Engineering, 13, 523, 10.1007/BF02477129
Spence, 2002, Electrical impedance measurement as an endpoint detection method for routine coagulation tests, British Journal of Biomedical Science, 59, 223, 10.1080/09674845.2002.11783664
Mungall, 1959, The electrical properties of human blood during coagulation, Medical Services Journal, Canada, 15
Blair, 1987, Whole blood clotting tests – an evaluation of five methods, Clinical and Laboratory Haematology, 9, 91, 10.1111/j.1365-2257.1987.tb01387.x
Graff, 1947, Electrical resistance of whole blood, Science, 106, 68, 10.1126/science.106.2742.68
Hayashi, 2010, A new approach to estimate venous thrombosis risk, Analytical Chemistry, 82, 9769, 10.1021/ac101927n
Hirsch, 1950, The electrical conductivity of blood. i. Relationship to erythrocyte concentration, Blood, 5, 1017, 10.1182/blood.V5.11.1017.1017
Henstell, 1949, Electrolytic resistance of the blood clot, American Journal of Physiology, 158, 367, 10.1152/ajplegacy.1949.158.3.367
Henstell, 1949, Electrolytic resistance of the blood clot – resistance clotting time, onset of clot retraction and the clot resistance, American Journal of Physiology, 158, 379, 10.1152/ajplegacy.1949.158.3.379
Xia, 1998, Soft lithography, Angewandte Chemie International Edition, 37, 550, 10.1002/(SICI)1521-3773(19980316)37:5<550::AID-ANIE550>3.0.CO;2-G
Quake, 2000, From micro- to nanofabrication with soft materials, Science, 290, 1536, 10.1126/science.290.5496.1536
Duffy, 1998, Rapid prototyping of microfluidic systems in poly(dimethylsiloxane), Analytical Chemistry, 70, 4974, 10.1021/ac980656z
Qin, 2010, Soft lithography for micro- and nanoscale patterning, Nature Protocols, 5, 491, 10.1038/nprot.2009.234
2009, A power-free blood plasma extraction device based on planar crossflow filter microstructure, 920
Seo, 2006, Effects on wettability by surfactant accumulation/depletion in bulk polydimethylsiloxane (PDMS), Sensors and Actuators B – Chemical, 119, 192, 10.1016/j.snb.2005.12.019
Zhou, 2010, Recent developments in PDMS surface modification for microfluidic devices, Electrophoresis, 31, 2, 10.1002/elps.200900475
Zhou, 2009, Convenient method for modifying poly(dimethylsiloxane) with poly(ethylene glycol) in microfluidics, Analytical Chemistry, 81, 6627, 10.1021/ac900551m
Sengupta, 2005, A simple low-cost lock-in amplifier for the laboratory, Journal of Chemical Education, 82, 1399, 10.1021/ed082p1399
Hartert, 1976, New aspects of blood-clotting and thrombosis – investigations with method of rheosimulation, Thrombosis Research, 8, 381, 10.1016/0049-3848(76)90080-3
Kahn, 2004, Enumeration of circulating tumor cells in the blood of breast cancer patients after filtration enrichment: correlation with disease stage, Breast Cancer Research And Treatment, 86, 237, 10.1023/B:BREA.0000036897.92513.72