Measurement of glycated hemoglobin (HbA1c) with an automated POCT instrument in comparison with HPLC and automated immunochemistry method: evaluation of the influence of hemoglobin variants

Alexander Haliassos1, Ioannis Drakopoulos2, Demosthenes G. Katritsis3, Nikolaos Chiotinis4, Socrates Korovesis5, Konstantinos Makris6
11. Central Laboratories, Athens Euroclinic, Athens, Greece
22. Clinical Biochemistry Laboratory, K.A.T. General Hospital, Kiffisia, Greece
33. Cardiology Department, Athens Euroclinic, Athens, Greece
44. Central Laboratories, Athens Euroclinic, Athens, Greece
55. Cardiology Department, Athens Euroclinic, Athens, Greece
66. Clinical Biochemistry Laboratory, K.A.T. General Hospital, Kiffisia, Greece

Tóm tắt

AbstractOur study evaluates a fast and easy way to perform point-of-care testing (POCT) measurements of glycated hemoglobin HbA

Từ khóa


Tài liệu tham khảo

Roberts, 1998, Effect of sickle trait and hemoglobin C trait on determinations of hemoglobin by an immunoassay method, Diabetes Care, 21, 1, 10.2337/diacare.21.6.983

Weykamp, 1993, der Influence of hemoglobin variants and derivatives on glycohemoglobin determinations , as investigated by laboratories using methods, Clin Chem, 16, 102

Edelman, 2002, Screening for diabetes in an outpatient clinic population, J Gen Intern Med, 17, 23, 10.1046/j.1525-1497.2002.10420.x

Perry, 2001, measurement improves the detection of type diabetes in high - risk individuals with nondiagnostic levels of fasting plasma glucose : the Early Diabetes Intervention Program, Diabetes Care, 24, 1, 10.2337/diacare.24.3.465

Sacks, 2002, Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus, Clin Chem, 48, 436, 10.1093/clinchem/48.3.436

Pope, 1993, A novel device for the rapid in - clinic measurement of haemoglobin, Diabet Med, 10, 1, 10.1111/j.1464-5491.1993.tb00054.x

Weykamp, 1994, der der reference values for glycohemoglobin in heterozygous , double - heterozygous and homozygous subjects , as established by methods, Hemoglobin Clin Chim Acta, 13, 231

Weykamp, 1993, der Interference of carbamylated and acetylated hemoglobin in assays of glycohemoglobin by HPLC electrophoresis affinity chromatography and enzyme immunoassay, Clin Chem, 39, 138, 10.1093/clinchem/39.1.138

Roberts, 1999, - Glycohemoglobin results in samples with hemoglobin C or S trait : a comparison of four test systems, Clin Chem, 45, 906, 10.1093/clinchem/45.6.906

Holownia, 1997, Adaptation of latex - enhanced assay for percent glycohemoglobin to a Dade Dimension analyzer, Clin Chem, 43, 76, 10.1093/clinchem/43.1.76

Greci, 2003, Utility of levels for diabetes case finding in hospitalized patients with hyperglycemia, Diabetes Care, 26, 1, 10.2337/diacare.26.4.1064