Functional neuromuscular stimulator for short-distance ambulation by certain thoracic-level spinal-cord-injured paraplegics

Surgical Neurology - Tập 50 - Trang 202-207 - 1998
Daniel Graupe1, Kate H Kohn2,3
1Department of Electrical Engineering & Computer Science, University of Illinois at Chicago, Illinois, USA
2Department of Rehabilitation Medicine & Restorative Medical Sciences, University of Illinois at Chicago, Chicago, Illinois, USA
3Department of Physical Medicine and Rehabilitation, Columbia/Michael Reese Hospital & Medical Center, Chicago, Illinois, USA

Tài liệu tham khảo

Galvani L. Commentary on the effect of electricity on muscular motion, (1791), Translated by R. M. Green, Cambridge, MA: Elizabeth Licht Publishing Co., 1953. Graupe D, Kralj A, Kohn KH. Computerized signature discrimination of above-lesion EMG for stimulating peripheral nerves of complete paraplegics. Proc. IFAC Symp on Prosthet. Control, Columbus, OH, March 1982. Graupe, 1984, Electromyographic control of FES in paraplegics, Orthopedics, 7, 1134, 10.3928/0147-7447-19840701-08 Graupe, 1994 Guest, 1997, Evaluation of a training program with SCI paraplegia using the Parastep-I ambulation system: part 4. Effect on physical self-concept and depression, Arch Phys Med Rehab, 78, 804, 10.1016/S0003-9993(97)90191-X Hjetlnes, 1990, Functional electrical stimulation for standing and walking with complete paraplegia, Paraplegia, 28, 235, 10.1038/sc.1990.30 Jacobs, 1997, Evaluation of a training program with SCI paraplegia using the Parastep-I ambulation system: part 2. Effects on physiological responses to peak arm ergometry, Arch Phys Med Rehab, 78, 794, 10.1016/S0003-9993(97)90189-1 Klose, 1997, Evaluation of a training program with SCI paraplegia using the Parastep-I ambulation system: part 1. Ambulation performance and anthropometric measures, Arch Phys Med Rehab, 78, 789, 10.1016/S0003-9993(97)90188-X Kralj, 1980, Electrical stimulation providing functional use of paraplegic patient muscles, Med Progr Technol, 7, 3 Liberson, 1961, Functional electrotherapy stimulation of the swing phase of the gait in hemiplegic patients, Arch Phys Med Rehab, 42, 101 Nash, 1997, Evaluation of a training program with SCI paraplegia using the Parastep-I ambulation system: part 5. Lower extremity blood flow and hyperemic responses to occlusion are augmented by ambulation training, Arch Phys Med Rehab, 78, 808, 10.1016/S0003-9993(97)90192-1 Needham-Shropshire, 1997, Evaluation of a training program with SCI paraplegia using the Parastep-I ambulation system: Part 3. Lack of effect on bone mineral density, Arch Phys Med Rehab, 78, 799, 10.1016/S0003-9993(97)90190-8