Evaluation of a wireless activity monitoring system to quantify locomotor activity in horses in experimental settings

Equine Veterinary Journal - Tập 49 Số 2 - Trang 225-231 - 2017
Michael Fries1, Stéphane Montavon2, Claudia Spadavecchia1, Olivier Levionnois1
1Division of Anaesthesiology and Pain Therapy, Department of Clinical Veterinary Sciences, Vetsuisse Faculty, University of Bern, Switzerland
2National Equine Centre, Bern, Switzerland

Tóm tắt

SummaryReasons for performing studyMethods of evaluating locomotor activity can be useful in efforts to quantify behavioural activity in horses objectively.ObjectivesTo evaluate whether an accelerometric device would be adequate to quantify locomotor activity and step frequency in horses, and to distinguish between different levels of activity and different gaits.Study designObservational study in an experimental setting.MethodsDual‐mode (activity and step count) piezo–electric accelerometric devices were placed at each of 4 locations (head, withers, forelimb and hindlimb) in each of 6 horses performing different controlled activities including grazing, walking at different speeds, trotting and cantering. Both the activity count and step count were recorded and compared by the various activities. Statistical analyses included analysis of variance for repeated measures, receiver operating characteristic curves, Bland–Altman analysis and linear regression.ResultsThe accelerometric device was able to quantify locomotor activity at each of the 4 locations investigated and to distinguish between gaits and speeds. The activity count recorded by the accelerometer placed on the hindlimb was the most accurate, displaying a clear discrimination between the different levels of activity and a linear correlation to speed. The accelerometer placed on the head was the only one to distinguish specifically grazing behaviour from standing. The accelerometer placed on the withers was unable to differentiate different gaits and activity levels. The step count function measured at the hindlimb was reliable but the count was doubled at the walk.ConclusionsThe dual‐mode accelerometric device was sufficiently accurate to quantify and compare locomotor activity in horses moving at different speeds and gaits. Positioning the device on the hindlimb allowed for the most accurate results. The step count function can be useful but must be manually corrected, especially at the walk.

Từ khóa


Tài liệu tham khảo

10.1016/j.cveq.2010.07.002

10.1111/j.2042-3306.2011.00412.x

10.2460/ajvr.68.3.246

Mama K.R., 1993, Evaluation of the interaction of mu and kappa opioid agonists on locomotor behavior in the horse, Can. J. Vet. Res., 57, 106

10.1046/j.1467-2995.2003.00134.x

10.2460/ajvr.73.2.290

10.1111/j.2042-3306.2012.00688.x

10.1016/j.cbpa.2005.07.019

10.1152/japplphysiol.01327.2009

10.1016/j.compag.2014.01.001

10.2460/javma.237.1.66

10.1111/j.1467-2995.2007.00367.x

10.1002/ajp.20476

10.2460/ajvr.68.5.468

10.1080/10543400701329422

10.1016/j.applanim.2013.11.014

10.1016/j.jevs.2010.10.005

10.1017/S1751731112000699

10.1249/mss.0b013e3804ec4e9

10.3390/s120608145

10.2460/ajvr.2005.66.589

10.1016/j.jevs.2012.02.013

10.2460/ajvr.72.7.866

10.1016/j.rvsc.2011.08.005

10.2460/ajvr.71.3.322

10.1016/j.jveb.2009.12.023

10.1249/01.MSS.0000064996.63632.10