Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants.

Thorax - Tập 51 Số 10 - Trang 985-988 - 1996
JH Wildhaber1,2, S G Devadason1,2, Ernst Eber1,2, Mark J. Hayden1,2, Mark L. Everard1,2, Q A Summers1,2, Peter N. Le Souëf1,2
1Department of Respiratory Medicine, Royal Perth Hospital, Perth, Western Australia
2Perth Medical Aerosol Research Group, Department of Respiratory Medicine, Princess Margaret Hospital for Children, Subiaco 6008, Perth, Western Australia

Tóm tắt

Từ khóa


Tài liệu tham khảo

Kim CS, Eldridge MA, Sackner MA. Oropharyngeal deposition and delivery aspects of metered dose inhaler aerosols. Am Rev Respir Dis 1987;135:157-64.

Konig P. Spacer devices used with metered-dose inhalers, break through or gimmick? Chest 1985;88:276-84.

Levison H, Reilly PA, Worsley GH. Spacing devices and metered-dose inhalers in childhood asthma. Jf Pediatr 1985;107:662-8.

Kraemer R, Birrer P, Modelska K, Casaulta Aebischer C, Schoni MH. A new baby-spacer device for aerosolized bronchodilator administration in infants with bronchopulmonary disease. EurJ7 Pediatr 1992;151:57-60.

Kraemer R, Frey U, Wirz Sommer C, Russi E. Short-term effect of albuterol, delivered via a new auxiliary device, in wheezy infants. Am Rev Respir Dis 1991;144:347-51.

Everard ML, Clark AR, Milner AD. Drug delivery from holding chambers with attached facemask. Arch Dis Child 1992;67:580-5.

O'Callaghan CO, Lynch J, Cant M, Robertson C. Improvement in drug delivery from spacer devices by use of an anti-static lining. Thorax 1993;48:603-6.

Bisgaard H. A metal aerosol holding chamber devised for young children with asthma. Eur Respir_ 1995;8:856-60.

Barry PW, O'Callaghan CO. The effect of delay, multiple actuations and spacer static charge on the in vitro delivery of budesonide from nebuhaler. Br J Clin Pharnmacol 1995; 40:76-8.

O'Callaghan CO, Cant M, Robertson C. Delivery of beclomethasone dipropionate from a spacer device: what dose is available for inhalation? Thorax 1994;49:961-4.

Barry PW, O'Callaghan CO. Multiple actuations of salbutamol MDI into a spacer device reduce the amount of drug recovered in the respirable range. Eur Respir _J 1994; 7:1707-9.

Bisgaard H, Anh0j J, Klug B, Berg E. A non-electrostatic spacer for aerosol delivery. Arch Dis Child 1995;73:226-30.

Zanon P. Inhalation antiasthma therapy with spacers: technical aspects. Monaldi Arch Chest Dis 1994;49:258-64.