Confocal and Multiphoton Imaging of Intracellular Ca2+

Methods in Cell Biology - Tập 99 - Trang 225-261 - 2010
Godfrey Smith1, Martyn Reynolds2, Francis Burton1, Ole Johan Kemi1
1School of Life Sciences, University of Glasgow, United Kingdom
2Cairn Research Limited, Faversham, Kent United Kingdom

Tài liệu tham khảo

Bestvater, 2002, Two-photon fluorescence absorption and emission spectra of dyes relevant for cell imaging, J. Microsc., 208, 108, 10.1046/j.1365-2818.2002.01074.x

Bliton, 1993, Optical modifications enabling simultaneous confocal imaging with dyes excited by ultra-violet and visible wavelength light, J. Microsc., 169, 15, 10.1111/j.1365-2818.1993.tb03274.x

Bullen, 2008, Microscopic imaging techniques for drug discovery, Nat. Rev. Drug Discov., 7, 54, 10.1038/nrd2446

Cleemann, 1997, Ca2+ sparks within 200nm of the sarcolemma of rat ventricular cells: Evidence from total internal reflection fluorescence microscopy, Adv. Exp. Med. Biol., 430, 57, 10.1007/978-1-4615-5959-7_5

Conchello, 2005, Optical sectioning microscopy, Nat. Methods, 2, 920, 10.1038/nmeth815

Conchello, 1994, Enhanced 3-D reconstruction from confocal scanning microscope images. II: Depth discrimination vs. signal-to-noise ratio in partially confocal images, Appl. Opt., 33, 3740, 10.1364/AO.33.003740

Cox, 2004, Practical limits of resolution in confocal and non-linear microscopy, Microsc. Res. Tech., 63, 18, 10.1002/jemt.10423

Denk, 1990, Two-photon laser scanning fluorescence microscopy, Science, 248, 73, 10.1126/science.2321027

Diaz, 2001, The effects of exogenous calcium buffers on the systolic calcium transient in rat ventricular myocytes, Biophys. J., 80, 1915, 10.1016/S0006-3495(01)76161-9

Diels, 1985, Control and measurement of ultrashort pulse shapes (in amplitude and phase) with femtosecond accuracy, Appl. Opt., 24, 1270, 10.1364/AO.24.001270

Fast, 2000, Simultaneous optical mapping of transmembrane potential and intracellular calcium in myocyte cultures, J. Cardiovasc. Electrophysiol., 11, 547, 10.1111/j.1540-8167.2000.tb00008.x

Hanley, 1999, An optical sectioning programmable array microscope implemented with a digital micromirror device, J. Microsc., 196, 317, 10.1046/j.1365-2818.1999.00602.x

Helmchen, 2005, Deep tissue two-photon microscopy, Nat. Methods, 2, 932, 10.1038/nmeth818

Jares-Erijman, 2003, FRET imaging, Nat. Biotechnol., 21, 1387, 10.1038/nbt896

Kettlewell, 2009, Changes of intra-mitochondrial Ca2+ in adult ventricular cardiomyocytes examined using a novel fluorescent Ca2+ indicator targeted to mitochondria, J. Mol. Cell. Cardiol., 46, 891, 10.1016/j.yjmcc.2009.02.016

Kim, 2008, Two-photon fluorescent probes for long-term imaging of calcium waves in live tissue, Chemistry, 14, 2075, 10.1002/chem.200701453

Lichtman, 2005, Fluorescence microscopy, Nat. Methods, 2, 910, 10.1038/nmeth817

Maravall, 2000, Estimating intracellular calcium concentrations and buffering without wavelength ratioing, Biophys. J., 78, 2655, 10.1016/S0006-3495(00)76809-3

Mashanov, 2003, Visualizing single molecules inside living cells using total internal reflection fluorescence microscopy, Methods, 29, 142, 10.1016/S1046-2023(02)00305-5

Masters, 2006

Miyawaki, 1997, Fluorescent indicators for Ca2+ based on green fluorescent proteins and calmodulin, Nature, 388, 882, 10.1038/42264

Miyawaki, 2003, Development of genetically encoded fluorescent indicators for calcium, Methods Enzymol., 360, 202, 10.1016/S0076-6879(03)60111-4

Nagai, 2001, Circularly permuted green fluorescent proteins engineered to sense Ca2+, Proc. Natl. Acad. Sci. USA, 98, 3197, 10.1073/pnas.051636098

1994

Tanaami, 2002, High-speed 1-frame/ms scanning confocal microscope with a microlens and Nipkow disk, Appl. Opt., 41, 4704, 10.1364/AO.41.004704

Thomas, 2000, A comparison of fluorescent Ca2+ indicator properties and their use in measuring elementary and global Ca2+ signals, Cell Calcium, 28, 213, 10.1054/ceca.2000.0152

Tsien, 1980, New calcium indicators and buffers with high selectivity against magnesium and protons: Design, synthesis, and properties of prototype structures, Biochemistry, 19, 2396, 10.1021/bi00552a018

Tsien, 1995, Video-rate confocal microscopy

Wang, 2005, Performance comparison between the high-speed Yokogawa spinning disc confocal system and single-point scanning confocal systems, J. Microsc., 218, 148, 10.1111/j.1365-2818.2005.01473.x

Webb, 1999, Theoretical basis of confocal microscopy, Methods Enzymol., 307, 3, 10.1016/S0076-6879(99)07003-2

Willig, 2006, STED microscopy reveals that synaptotagmin remains clustered after synaptic vesicle exocytosis, Nature, 440, 935, 10.1038/nature04592

Wilson, 1996, Confocal microscopy by aperture correlation, Opt. Lett., 21, 1879, 10.1364/OL.21.001879

Wokosin, 2004, Characterization of a range of Fura dyes with two-photon excitation, Biophys. J., 86, 1726, 10.1016/S0006-3495(04)74241-1

Xu, 1996, Multiphoton fluorescence excitation: New spectral windows for biological nonlinear microscopy, Proc. Natl. Acad. Sci. USA, 93, 10763, 10.1073/pnas.93.20.10763

Zipfel, 2003, Nonlinear magic: Multiphoton microscopy in the biosciences, Nat. Biotechnol., 21, 1369, 10.1038/nbt899