Comparison of simplified quantitative analyses of FDG uptake

Nuclear Medicine and Biology - Tập 27 Số 7 - Trang 647-655 - 2000
Michael M. Graham1, Lanell M. Peterson2, R.M Hayward2
1University of Iowa, Iowa City, Iowa, USA
2Univ. of Washington, Seattle, Washington, USA

Tóm tắt

Từ khóa


Tài liệu tham khảo

DeGrado, 1994, Performance characteristics of a whole-body PET scanner, J. Nucl. Med., 35, 1398

DuBois, 1916, A formula to estimate the approximate surface area if height and weight be known, Arch. Int. Med., 17, 863, 10.1001/archinte.1916.00080130010002

Gehan, 1970, Estimation of human body surface area from height and weight, Cancer Chemotherapy Report, 54, 225

Gjedde, 1982, Calculation of cerebral glucose phosphorylation from brain uptake of glucose analogs in vivo, Brain Res. Rev., 4, 237, 10.1016/0165-0173(82)90018-2

Graham, 1997, Physiologic smoothing of blood time-activity curves for PET data analysis, J. Nucl. Med., 38, 1161

Hamberg, 1994, The dose uptake ratio as an index of glucose metabolism, J. Nucl. Med., 35, 1308

Haycock, 1978, Geometric method for measuring body surface area, J. Pediat., 93, 62, 10.1016/S0022-3476(78)80601-5

Hunter, 1996, Simplified measurement of deoxyglucose utilization rate, J. Nucl. Med., 37, 950

Jerusalem, 1999, Whole-body positron emission tomography using 18F-fluorodeoxyglucose for posttreatment evaluation in Hodgkin’s Disease and Non-Hodgkin’s Lymphoma has higher diagnostic and prognostic value than classical computed tomography scan imaging, Blood, 94, 429, 10.1182/blood.V94.2.429

Keyes, 1995, SUV, J. Nucl. Med., 36, 1836

Kim, 1994, Standardized uptake values of FDG, J. Nucl. Med., 35, 164

Kitagawa, 1999, FDG PET to evaluate combined intra-arterial chemotherapy and radiotherapy of head and neck neoplasms, J. Nucl. Med., 40, 1132

Lewellen, 1996, Investigation of the performance of the General Electric ADVANCE positron emission tomograph in 3D mode, IEEE Trans. Nucl. Sci., 43, 2199, 10.1109/23.531882

Lewellen, 1995, Investigation of the count rate performance of General Electric Advance positron emission tomograph, IEEE Trans. Nuclear Sci., 42, 1051, 10.1109/23.467750

Lowe, 1998, Prospective investigation of positron emission tomography in lung nodules, J. Clin. Oncol., 16, 1075, 10.1200/JCO.1998.16.3.1075

Mosteller, 1987, Simplified calculation of body-surface area, N. Engl. J. Med., 317, 1098, 10.1056/NEJM198710223171717

Patlak, 1983, Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data, J. Cereb. Blood Flow Metab., 3, 1, 10.1038/jcbfm.1983.1

Phelps, 1979, Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18)2-fluoro-2-deoxy-D-glucose, Ann. Neurol., 6, 371, 10.1002/ana.410060502

Press, 1989

Schomburg, 1996, Standardized uptake values of fluorine-18 fluorodeoxyglucose, Eur. J. Nucl. Med., 23, 571, 10.1007/BF00833394

Sokoloff, 1977, The [14C]deoxyglucose method for the measurement of local cerebral glucose utilization, J. Neurochem., 28, 897, 10.1111/j.1471-4159.1977.tb10649.x

Spence, 1998, Glucose metabolism in human malignant gliomas measured quantitatively with PET, 1-[11C]glucose and FDG, J. Nucl. Med., 39, 440

Zasadny, 1993, Standardized uptake values of normal tissues at PET with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose, Radiology, 189, 847, 10.1148/radiology.189.3.8234714