Tài liệu tham khảo
Bargar, 1998, Primary and revision total hip replacement using the Robodoc system, Clin Orthop, 354, 82, 10.1097/00003086-199809000-00011
Bourne, 1994, Ingrowth surfaces. Plasma spray coating to titanium alloy hip replacements, Clin Orthop, 298, 37, 10.1097/00003086-199401000-00007
Bourne, 1998, A critical look at cementless stems, Clin Orthop, 355, 212, 10.1097/00003086-199810000-00022
Burkart, 1993, Thigh pain in cementless total hip arthroplasty: a comparison of two systems at 2 years’ follow-up, Orthop Clin North Am, 24, 645, 10.1016/S0030-5898(20)31844-7
Charnley, 1973, Low-friction arthroplasty in congenital subluxation of the hip, Clin Orthop, 91, 98, 10.1097/00003086-197303000-00015
Clarke, 1992, Computerized templating in uncemented total hip arthroplasty to assess component fit and fill, J Arthroplasty, 7, 235, 10.1016/0883-5403(92)90042-O
Crowe, 1979, Total hip replacement in congenital dislocation and dysplasia of the hip, J Bone Joint Surg Am, 61, 15, 10.2106/00004623-197961010-00004
Dorr, 1997, Failure mechanisms of Anatomic Porous Replacement I cementless total hip replacement, Clin Orthop, 334, 157, 10.1097/00003086-199701000-00021
Dunn, 1976, Total hip reconstruction in chronically dislocated hips, J Bone Joint Surg Am, 58, 838, 10.2106/00004623-197658060-00015
Eckrich, 1994, Effect of rotation on the radiographic appearance of the femoral canal, J Arthroplasty, 9, 419, 10.1016/0883-5403(94)90053-1
Engh, 1990, The case for porous-coated hip implants. The femoral side, Clin Orthop, 261, 63, 10.1097/00003086-199012000-00009
Huiskes, 1990, The various stress patterns of press-fit, ingrown, and cemented femoral stems, Clin Orthop, 261, 27, 10.1097/00003086-199012000-00006
Huo, 1995, Total hip arthroplasty using the Zweymuller stem implanted without cement, J Arthroplasty, 10, 793, 10.1016/S0883-5403(05)80077-4
Lahmer, 1998, Is there a difference between the planning and the real position of the shaft 300 days after a robot assisted total hip replacement?, 694
Mallory, 1992, Total hip replacement in the 1990s: the procedure, the patient, the surgeon, Orthopedics, 15, 427, 10.3928/0147-7447-19920401-06
Mallory, 1996, Clinical and radiographic outcome of a cementless, titanium, plasma-spray coated total hip arthroplasty femoral component. Justification for continuance of use, J Arthroplasty, 11, 653, 10.1016/S0883-5403(96)80002-7
Merle d’Aubigné, 1954, Functional results of hip arthroplasty with acrylic prosthesis, J Bone Joint Surg Am, 36, 451, 10.2106/00004623-195436030-00001
Mulliken, 1996, A tapered titanium femoral stem inserted without cement in a total hip arthroplasty, J Bone Joint Surg Am, 78, 1214, 10.2106/00004623-199608000-00012
Nogler, 2001, Knee pain caused by a fiducial marker in the medial femoral condyle, Acta Orthop Scand, 72, 477, 10.1080/000164701753532808
Otani, 1993, The effect of axial and torsional loading on strain distribution in the proximal femur as related to cementless total hip arthroplasty, Clin Orthop, 292, 376, 10.1097/00003086-199307000-00049
Paul, 1992, Development of a surgical robot for cementless total hip arthroplasty, Clin Orthop, 285, 57, 10.1097/00003086-199212000-00010
Reuben, 1992, A knowledge-based computer-aided and manufacturing system for total hip replacement, Clin Orthop, 285, 48, 10.1097/00003086-199212000-00009
Sugano, 1998, The morphology of the femur in developmental dysplasia of the hip, J Bone Joint Surg Br, 80, 711, 10.1302/0301-620X.80B4.8319