Assessing walking ability in subjects with spinal cord injury: Validity and reliability of 3 walking tests

Archives of Physical Medicine and Rehabilitation - Tập 86 Số 2 - Trang 190-196 - 2005
Hubertus J. A. van Hedel1,2, Markus Wirz3, Volker Dietz3
1Department of Medical Physics & Biophysics, Catholic University Nijmegen, Nijmegen, The Netherlands.
2Spinal Cord Injury Center, Balgrist University Hospital, Zürich, Switzerland
3Spinal Cord Injury Center, Balgrist University Hospital, Zurich, Switzerland

Tóm tắt

Từ khóa


Tài liệu tham khảo

Dawson-Saunders, 1994

Harada, 1999, Mobility-related function in older adults, Arch Phys Med Rehabil, 80, 837, 10.1016/S0003-9993(99)90236-8

Steffen, 2002, Age- and gender-related test performance in community-dwelling elderly people, Phys Ther, 82, 128, 10.1093/ptj/82.2.128

Rossier, 2001, Validity and reliability comparison of 4 mobility measures in patients presenting with neurologic impairment, Arch Phys Med Rehabil, 82, 9, 10.1053/apmr.2001.9396

Smith, 1999, Achievement of simple mobility milestones after stroke, Arch Phys Med Rehabil, 80, 442, 10.1016/S0003-9993(99)90283-6

Morris, 2001, Reliability of measurements obtained with the Timed “Up & Go” test in people with Parkinson disease, Phys Ther, 81, 810, 10.1093/ptj/81.2.810

Schenkman, 1997, Reliability of impairment and physical performance measures for persons with Parkinson’s disease, Phys Ther, 77, 19, 10.1093/ptj/77.1.19

Schoppen, 1999, The Timed “up and go” test, Arch Phys Med Rehabil, 80, 825, 10.1016/S0003-9993(99)90234-4

Field-Fote, 2001, The spinal cord injury functional ambulation inventory (SCI-FAI), J Rehabil Med, 33, 177, 10.1080/165019701750300645

Ditunno, 2000, Walking index for spinal cord injury (WISCI), Spinal Cord, 38, 234, 10.1038/sj.sc.3100993

Dittuno, 2001, Walking index for spinal cord injury (WISCI II), Spinal Cord, 39, 654, 10.1038/sj.sc.3101223

Podsiadlo, 1991, The timed “Up & Go”, J Am Geriatr Soc, 39, 142, 10.1111/j.1532-5415.1991.tb01616.x

Mathias, 1986, Balance in elderly patients, Arch Phys Med Rehabil, 67, 387

Butland, 1982, Two-, six-, and 12-minute walking tests in respiratory disease, Br Med J (Clin Res Ed), 284, 1607, 10.1136/bmj.284.6329.1607

Guyatt, 1985, The 6-minute walk, Can Med Assoc J, 132, 919

Roomi, 1996, Respiratory rehabilitation, exercise capacity and quality of life in chronic airways disease in old age, Age Ageing, 25, 12, 10.1093/ageing/25.1.12

Cahalin, 1996, The six-minute walk test predicts peak oxygen uptake and survival in patients with advanced heart failure, Chest, 110, 325, 10.1378/chest.110.2.325

Mossberg, 2003, Reliability of a timed walk test in persons with acquired brain injury, Am J Phys Med Rehabil, 82, 385, 10.1097/01.PHM.0000052589.96202.BE

Arnadottir, 2000, Effects of footwear on measurements of balance and gait in women between the ages of 65 and 93 years, Phys Ther, 80, 17, 10.1093/ptj/80.1.17

Bland, 1986, Statistical methods for assessing agreement between two methods of clinical measurement, Lancet, 1, 307, 10.1016/S0140-6736(86)90837-8

Berg, 1992, Clinical and laboratory measures of postural balance in an elderly population, Arch Phys Med Rehabil, 73, 1073

Cahalin, 1995, The relationship of the 6-min walk test to maximal oxygen consumption in transplant candidates with end-stage lung disease, Chest, 108, 452, 10.1378/chest.108.2.452

Zäch, 1995, [Demography and statistics of paraplegia] [German], 16

Enright, 1998, Reference equations for the six-minute walk in healthy adults, Am J Respir Crit Care Med, 158, 1384, 10.1164/ajrccm.158.5.9710086