A time-delay calibrated method for cornea hysteresis and intraocular pressure measurement
Tóm tắt
The presence of cornea hysteresis (CH) in characterizing the intraocular pressure (IOP) of a human eye deteriorates the accuracy of IOP. To suppress CH, the pressure gauge of a tonometer must be located as close as possible to the cornea. However, this arrangement is unpractical because appropriate working distance to the cornea is required. In this paper, a time-delay calibrated (TDC) method is proposed to counteract the undesired effect of CH in characterizing the IOP. Employing this TDC method, the CH approaches to zero for most eyes measured.
Tài liệu tham khảo
citation_journal_title=Description and clinical evaluation. Arch. Ophthalmol.; citation_title=A noncontact applanation tonometer; citation_author=M Forbes, G Pico, B Grolman; citation_volume=91; citation_publication_date=1974; citation_pages=134; citation_id=CR1
citation_journal_title=PLoS One; citation_title=Corneal viscoelastic properties from finite-element analysis of in vivo air-puff deformation; citation_author=S Kling, N Bekesi, C Dorronsoro, D Pascual, S Marcos; citation_volume=9; citation_publication_date=2014; citation_pages=e104904; citation_doi=10.1371/journal.pone.0104904; citation_id=CR2
citation_journal_title=Klin. Monatsbl. Augenheilkd.; citation_title=Influence of corneal thickness on comparative intraocular pressure measurements with Goldmann and non-contact tonometers in keratoconus; citation_author=MŠ Šilih, M Hawlina; citation_volume=220; citation_publication_date=2003; citation_pages=843; citation_doi=10.1055/s-2003-812557; citation_id=CR3
citation_journal_title=Arch. Ophthalmol.; citation_title=Clinical comparison of the Proview eye pressure monitor with the Goldmann applanation tonometer and the Tonopen; citation_author=J Li, LW Herndon, SG Asrani, S Stinnett, RR Allingham; citation_volume=122; citation_publication_date=2004; citation_pages=1117; citation_doi=10.1001/archopht.122.8.1117; citation_id=CR4
citation_journal_title=Clin. Exp. Optom.; citation_title=The relationship between central corneal thickness and Goldmann applanation tonometry; citation_author=A Lleo, A Marcos, M Calatayud, L Alonso, SM Rahhal, JA Sanchis-Gimeno; citation_volume=86; citation_publication_date=2003; citation_pages=104; citation_doi=10.1111/j.1444-0938.2003.tb03068.x; citation_id=CR5
citation_journal_title=J. Refract. Surg.; citation_title=Corneal hysteresis, resistance factor, topography, and pachymetry after corneal lamellar flap; citation_author=D Gatinel, S Chaabouni, PA Adam, J Munck, M Puech, T Hoang-Xuan; citation_volume=23; citation_publication_date=2007; citation_pages=76; citation_id=CR6
citation_journal_title=J. Curr. Glaucoma Pract.; citation_title=The ocular response analyze; citation_author=AV Sathi Devi; citation_volume=3; citation_publication_date=2009; citation_pages=24; citation_id=CR7
citation_journal_title=Am. J. Ophthalmol.; citation_title=Central corneal thickness and corneal hysteresis associated with glaucoma damage; citation_author=NG Congdon, AT Broman, K Bandeen-Roche, D Grover, HA Quigley; citation_volume=141; citation_publication_date=2006; citation_pages=868; citation_doi=10.1016/j.ajo.2005.12.007; citation_id=CR8