A progressive comparison of the novel pulse and conventional steady state methods of measuring the airtightness of buildings
Tài liệu tham khảo
Lombard, 2008, A review on buildings energy consumption information, Energy and Buildings, 40, 394, 10.1016/j.enbuild.2007.03.007
International Energy Agency, 2013. Transition to Sustainable Buildings-Strategies and Opportunities to 2050 Available from: http://www.iea.org/Textbase/npsum/building2013SUM.pdf.
S.J. Emmerich, et al. Impact of infiltration on heating and cooling loads in U.S. office buildings, Department of Energy, Office of Building Technologies. Agreement No. DE-AI01-01EE27615.
Jokisalo, 2009, Building Leakage, infiltration, and energy performance analyses for Finnish detached houses, Build. Environ., 44, 377, 10.1016/j.buildenv.2008.03.014
Department for Business, Energy & Industrial Strategy. Energy consumption in the UK (ECUK) 1970 to 2018, National Statistics, 25 July 2019.
Sherman, 1989, Uncertainty in air flow calculations using tracer gas measurements, Build. Environ., 24, 347, 10.1016/0360-1323(89)90029-2
Blomsterberg, 1979, A model correlating air tightness and air infiltration in houses
Dols, 2000
Sherman, 1980
Walker, 1990
Almeida, 2017, A contribution to the quantification of the influence of windows on the tightness of buildings in southern Europe, Energy Build., 139, 174, 10.1016/j.enbuild.2017.01.012
Etheridge, 1996
Vinha, 2015, Airtightness of residential buildings in Finland, Build. Environ., 93, 128, 10.1016/j.buildenv.2015.06.011
M.H. Sherman, D.T. Grimsrud, R.C. Sonderegger. The low pressure leakage function of a building LBL-9162, EEB-Env-79-10.
Siren, 1997, A modification of the power law equation to account for large-scale wind turbulence, 557
Cooper, 2007, Determining the adventitious leakage of buildings at low pressure. Part 2, Eng. Res. Technol, 28, 81
Sherman, 2004
Modera, 1991, 2009
Pasos, 2019, Experimental study on the pressure differential at which building air leakage should be measured
Cooper, 2007, Determining the adventitious leakage of buildings at low pressure. Part 1: uncertainties, Building Serv. Eng. Res. Technol., 28, 71, 10.1177/0143624406072330
Wood, 2018, An extended pressure range comparison of the blower door and novel pulse method for measuring the airtightness of two outdoor chambers with different levels of airtightness
Cooper, 2014, A nozzle pulse pressurisation technique for measurement of building leakage at low pressure
Hsu, 2019, Evaluation of indoor pressure distributions in a detached house using the Pulse airtightness measurement technique
Hsu, 2021, Evaluation of indoor pressure distributions in a detached house using the Pulse airtightness measurement technique, Build. Environ., 107742, 10.1016/j.buildenv.2021.107742
Zheng, 2019, Experimental insights into the airtightness measurement of a house-sized chamber in a sheltered environment using blower door and pulse methods, Build. Environ., 10.1016/j.buildenv.2019.106269
Zheng, 2019, Refined assessment and comparison of airtightness measurement of indoor chambers using the blower door and Pulse methods
Zheng, 2019, Experimental studies of a pulse pressurisation technique for measuring building airtightness, Future Cities Environ., 5, 1, 10.5334/fce.66