A progressive comparison of the novel pulse and conventional steady state methods of measuring the airtightness of buildings

Energy and Buildings - Tập 261 - Trang 111983 - 2022
X.F. Zheng1,2, Y.S. Hsu1, A.V. Pasos1, L. Smith3, C.J. Wood1
1Buildings, Energy and Environment Research Group, Faculty of Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK
2School of Built Environment, Engineering and Computing, Leeds Beckett University, Leeds, LS1 3HE, UK
3Build Test Solutions Ltd., 16 St Johns Business Park, Lutterworth LE17 4HB, UK

Tài liệu tham khảo

Lombard, 2008, A review on buildings energy consumption information, Energy and Buildings, 40, 394, 10.1016/j.enbuild.2007.03.007

International Energy Agency, 2013. Transition to Sustainable Buildings-Strategies and Opportunities to 2050 Available from: http://www.iea.org/Textbase/npsum/building2013SUM.pdf.

S.J. Emmerich, et al. Impact of infiltration on heating and cooling loads in U.S. office buildings, Department of Energy, Office of Building Technologies. Agreement No. DE-AI01-01EE27615.

Jokisalo, 2009, Building Leakage, infiltration, and energy performance analyses for Finnish detached houses, Build. Environ., 44, 377, 10.1016/j.buildenv.2008.03.014

Department for Business, Energy & Industrial Strategy. Energy consumption in the UK (ECUK) 1970 to 2018, National Statistics, 25 July 2019.

Sherman, 1989, Uncertainty in air flow calculations using tracer gas measurements, Build. Environ., 24, 347, 10.1016/0360-1323(89)90029-2

Blomsterberg, 1979, A model correlating air tightness and air infiltration in houses

Dols, 2000

Sherman, 1980

Walker, 1990

Almeida, 2017, A contribution to the quantification of the influence of windows on the tightness of buildings in southern Europe, Energy Build., 139, 174, 10.1016/j.enbuild.2017.01.012

Etheridge, 1996

Vinha, 2015, Airtightness of residential buildings in Finland, Build. Environ., 93, 128, 10.1016/j.buildenv.2015.06.011

M.H. Sherman, D.T. Grimsrud, R.C. Sonderegger. The low pressure leakage function of a building LBL-9162, EEB-Env-79-10.

Siren, 1997, A modification of the power law equation to account for large-scale wind turbulence, 557

Cooper, 2007, Determining the adventitious leakage of buildings at low pressure. Part 2, Eng. Res. Technol, 28, 81

Sherman, 2004

Modera, 1991, 2009

Pasos, 2019, Experimental study on the pressure differential at which building air leakage should be measured

Cooper, 2007, Determining the adventitious leakage of buildings at low pressure. Part 1: uncertainties, Building Serv. Eng. Res. Technol., 28, 71, 10.1177/0143624406072330

Wood, 2018, An extended pressure range comparison of the blower door and novel pulse method for measuring the airtightness of two outdoor chambers with different levels of airtightness

Cooper, 2014, A nozzle pulse pressurisation technique for measurement of building leakage at low pressure

Hsu, 2019, Evaluation of indoor pressure distributions in a detached house using the Pulse airtightness measurement technique

Hsu, 2021, Evaluation of indoor pressure distributions in a detached house using the Pulse airtightness measurement technique, Build. Environ., 107742, 10.1016/j.buildenv.2021.107742

Zheng, 2019, Experimental insights into the airtightness measurement of a house-sized chamber in a sheltered environment using blower door and pulse methods, Build. Environ., 10.1016/j.buildenv.2019.106269

Zheng, 2019, Refined assessment and comparison of airtightness measurement of indoor chambers using the blower door and Pulse methods

Zheng, 2019, Experimental studies of a pulse pressurisation technique for measuring building airtightness, Future Cities Environ., 5, 1, 10.5334/fce.66

Carrie, 2016, Uncertainties in building pressurisation tests due to steady wind, Energy Build., 116, 656, 10.1016/j.enbuild.2016.01.029