Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: A systematic review

Manual Therapy - Tập 19 - Trang 10-17 - 2014
Eva Barrett1, Karen McCreesh1, Jeremy Lewis2,3
1Department of Clinical Therapies, Faculty of Education and Health Sciences, University of Limerick, Limerick, Ireland
2Musculoskeletal Services, Health at the Stowe, Central London Community Healthcare, NHS Trust, 260 Harrow Road, London W2 5ES, UK
3Department of Allied Health Professions and Midwifery, School of Health and Social Work, Wright Building, College Lane Campus, University of Hertfordshire, Hatfield AL10 9AB, Hertfordshire, UK

Tài liệu tham khảo

Adhia, 2012, Validity and reliability of palpation-digitization for non-invasive kinematic measurement, a systematic review, Man Ther, 1 Ayub, 1991, Posture and the upper quarter, 81 Billis, 2003, Reproducibility and repeatability: errors of three groups of physiotherapists in locating spinal levels by palpation, Man Ther, 8, 223, 10.1016/S1356-689X(03)00017-1 Briggs, 2007, Radiographic measures of thoracic kyphosis in osteoporosis: Cobb and vertebral centroid angles, Skeletal Radiol, 36, 761, 10.1007/s00256-007-0284-8 Brink, 2011, Clinical instruments: reliability and validity critical appraisal, J Eval Clin Pract, 1 Chaise, 2011, Validation, repeatability and reproducibility of a non-invasive instrument for measuring thoracic and lumbar curvature of the spine in the sagittal plane, Revista Brasileira de Fisioterapia, 15, 511, 10.1590/S1413-35552011005000031 Calliet, 1991 Carmines, 1979 Chen, 1999, Vertebral centroid measurement of lumbar lordosis compared with the Cobb technique, Spine, 24, 1786, 10.1097/00007632-199909010-00007 Czaprowski, 2012, Intra- and inter-observer repeatability of the assessment of anteroposterior curvatures of the spine using Saunders digital inclinometer, Ortopaedic Traumatol Rehabil, 14, 145, 10.5604/15093492.992283 de Oliveira, 2012, Validity and reproducibility of the measurements obtained using the flexicurve instrument to evaluate the angles of thoracic and lumbar curvatures of the spine in the sagittal plane, Rehabil Res Pract, 1 Di Bari, 2004, Thoracic kyphosis and ventilator dysfunction in unselected older persons: an epidemiological study in Dicomano, Italy, J Am Geriatr Soc, 52, 909, 10.1111/j.1532-5415.2004.52257.x D'Osualdo, 1997, Validation of clinical measurement of kyphosis with a simple instrument, the arcometer, Spine, 22, 408, 10.1097/00007632-199702150-00011 Dunk, 2005, Implications for the use of postural analysis as a clinical diagnostic tool: reliability of quantifying upright standing spinal postures from photographic images, J Manipulative Physiol Ther, 28, 386, 10.1016/j.jmpt.2005.06.006 Dunk, 2004, The reliability of quantifying upright standing postures as a baseline diagnostic clinical tool, J Manipulative Physiol Ther, 27, 91, 10.1016/j.jmpt.2003.12.003 Fölsch, 2012, Test-retest reliability of 3D ultrasound measurements of the thoracic spine, J Inj Funct Rehabil, 4, 335 French, 2000, Reliability of chiropractic methods commonly used to detect manipulable lesions in patients with chronic low-back pain, J Manipulative Physiol Ther, 23, 231, 10.1067/mmt.2000.106101 Goh, 1999, Rasterstereographic analysis of the thoracic sagittal curvature: a reliability study, J Musculoskelet Res, 3, 137, 10.1142/S0218957799000142 Gravina, 2012, Goniometer evaluation of thoracic kyphosis and lumbar lordosis in subjects during growth age: a validity study, Stud Health Technology Inform, 176, 247 Gray, 2004, Interrelationship of the spine, rib cage, and shoulder, 133 Greendale, 2011, The reliability and validity of three non-radiological measures of thoracic kyphosis and their relations to the standing radiological Cobb angle, Osteoporos Int, 22, 1897, 10.1007/s00198-010-1422-z Haneline, 2009, A review of intraexaminer and interexaminer reliability of static spinal palpation: a literature synthesis, J Manipulative Physiol Ther, 32, 379, 10.1016/j.jmpt.2009.04.010 Harrison, 2001, Reliability of centroid, Cobb, and Harrison posterior tangent methods: which to choose for analysis of thoracic kyphosis, Spine, 26, 227, 10.1097/00007632-200106010-00002 Hinman, 2004, Interrater reliability of flexicurve postural measures among novice users, J Back Musculoskelet Rehabil, 17, 33, 10.3233/BMR-2004-17107 Horter, 1978, How to care for your neck, Phys Ther, 52, 184, 10.1093/ptj/58.2.184 Kado, 2007, Hyperkyphotic posture and risk of injurious falls in older persons: the Rancho Bernardo Study, J Gerontol Biol Sci, 62, 682 Kellis, 2008, Reliability of spinal range of motion in healthy boys using a skin-surface device, J Manipulative Physiol Ther, 31, 570, 10.1016/j.jmpt.2008.09.001 Korovessis, 2001, Prediction of thoracic kyphosis using the Debrunner kyphometer, J Spinal Disord, 14, 67, 10.1097/00002517-200102000-00010 Langenderfer, 2009, A multi-subject evaluation of uncertainty in anatomical landmark location on shoulder kinematic description, Computer Methods Biomech Biomed Eng, 12, 211, 10.1080/10255840802372094 Leroux, 2000, A non-invasive anthropometric technique for measuring kyphosis and lordosis, an application for idiopathic scoliosis, Spine, 25, 1689, 10.1097/00007632-200007010-00012 Lewis, 2010, Clinical measurement of the thoracic kyphosis. A study of the intra-rater reliability in subjects with and without shoulder pain, BMC Musculoskelet Disord, 11, 39, 10.1186/1471-2474-11-39 Liberati, 2009, The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration, PLoS Med, 6, e1000100, 10.1371/journal.pmed.1000100 Lohr, 2002, Assessing health status and quality-of-life instruments: attributes and review criteria, Qual Life Res, 11, 193, 10.1023/A:1015291021312 Lundon, 1998, Interrater and intrarater reliability in the measurement of kyphosis in postmenopausal women with osteoporosis, Spine, 23, 1978, 10.1097/00007632-199809150-00013 Lydick, 1997, Development and validation of a discriminative quality of life questionnaire for osteoporosis, Journal Bone Mineral Research, 12, 456, 10.1359/jbmr.1997.12.3.456 Mannion, 2004, A new skin-surface device for measuring the curvature and global and segmental ranges of motion of the spine: reliability of measurements and comparison with data reviewed from the literature, Eur Spine J, 13, 122, 10.1007/s00586-003-0618-8 May, 2010, Reliability of physical examination tests used in the assessment of patients with shoulder problems: a systematic review, Physiotherapy, 96, 179, 10.1016/j.physio.2009.12.002 May, 2006, Reliability of procedures used in the physical examination of non-specific low back pain: a systematic review, Aust J Physiother, 52, 91, 10.1016/S0004-9514(06)70044-7 Melvin, 2010, Reproducibility of rasterstereography for kyphotic and lordotic angles, trunk length and trunk inclination, a reliability study, Spine, 35, 1353, 10.1097/BRS.0b013e3181cbc157 Milne, 1983, A longitudinal study of kyphosis in older people, Age Ageing, 12, 225, 10.1093/ageing/12.3.225 Munro, 2005, 239 Murray, 1993, The natural history and long-term follow-up of Scheuermann kyphosis, J Bone Joint Surg, 75, 236, 10.2106/00004623-199302000-00011 O'Haire, 2000, Inter-examiner and intra-examiner agreement for assessing sacroiliac anatomical landmarks using palpation and observation: pilot study, Man Ther, 5, 13, 10.1054/math.1999.0203 Öhlén, 1989, Measurement of spinal sagittal configuration and mobility with Debrunner's kyphometer, Spine, 14, 580, 10.1097/00007632-198906000-00006 Perriman, 2010, Validation of the flexible electrogoniometer for measuring thoracic kyphosis, Spine, 35, 633, 10.1097/BRS.0b013e3181d13039 Portney, 2000 Purser, 1999, Reliability of physical performance tests in four different randomized clinical trials, Arch Phys Med Rehabil, 80, 557, 10.1016/S0003-9993(99)90199-5 Ripani, 2008, Spinal curvature: comparison of frontal measurements with the spinal mouse and radiographic assessment, J Sports Med Phys Fitness, 48, 488 Saad, 2012, Reliability of photogrammetry in the evaluation of the postural aspects of individuals with structural scoliosis, J Bodywork Movement Therapies, 16, 210, 10.1016/j.jbmt.2011.03.005 Sheeran, 2010, Preliminary study: reliability of the spinal wheel. A novel device to measure spinal postures applied to sitting and standing, Eur Spine J, 19, 995, 10.1007/s00586-009-1241-0 Stochkendahl, 2006, Manual examination of the spine: a systematic critical literature review of reproducibility, J Manipulative Physiol Ther, 29, 475, 10.1016/j.jmpt.2006.06.011 Teixeira, 2007, Reliability and validity of thoracic kyphosis measurements using flexicurve method, Revista Brasileira de Fisioterapia, 11, 199 Terwee, 2007, Quality criteria were proposed for measurement properties of health status questionnaires, J Clin Epidemiol, 60, 34, 10.1016/j.jclinepi.2006.03.012 Van Blommestein, 2012, Reliability os measuring thoracic kyphosis angle, lumbar lordosis angle and straight leg raise with an inclinometer, Open Spine J, 4, 10, 10.2174/1876532701204010010 van de Ven-Stevens, 2009, Clinimetric properties of instruments to assess activities in patients with hand injury: a systematic review of the literature, Arch Phys Med Rehabil, 90, 151, 10.1016/j.apmr.2008.06.024 van der Wurff, 2000, Clinical tests of the sacroiliac joint. A systematic methodological review. Part 1, Reliability Manual Therapy, 5, 30, 10.1054/math.1999.0228 van Tulder, 2003, Updated method guidelines for systematic reviews in the Cochrane Collaboration Back Review Group, 10.1097/01.BRS.0000065484.95996.AF Whiting, 2003, The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews, BMC Med Res Methodol, 3, 25, 10.1186/1471-2288-3-25 Willner, 1981, Spinal pantograph: a non-invasive technique for describing kyphosis and lordosis in the thoraco-lumbar spine, Acta Orthop Scand, 52, 525, 10.3109/17453678108992142 Wright, 1992, Improving the reliability of orthopaedic measurements, J Bone Joint Surg, 74, 287, 10.1302/0301-620X.74B2.1544971 Yanagawa, 2000, Assessment of thoracic kyphosis using the flexicurve for individuals with osteoporosis, Hong Kong Physiother J, 18, 53, 10.1016/S1013-7025(00)18004-2