Évaluation de la valeur prédictive positive de la scintigraphie aux leucocytes marqués dans le diagnostic d’infections ostéo-articulaires
Tài liệu tham khảo
Ziza, 1997, Infections on joint prostheses, Rev Med Interne, 18, 431s, 10.1016/S0248-8663(97)80150-6
Kraft, 2001, Radiological signs of osteitis around extramedullary metal implants. A radiographic-microbiological correlative analysis in rabbit tibiae after local inoculation of Staphylococcus aureus, Arch Orthop Trauma Surg, 121, 338, 10.1007/s004020000235
Munk, 1994, Imaging after arthroplasty, Can Assoc Radiol J, 45, 6
Palestro, 2006, Infection and musculoskeletal conditions: imaging of musculoskeletal infections, Best Pract Res Clin Rheumatol, 20, 1197, 10.1016/j.berh.2006.08.009
Elgazzar, 1995, Multimodality imaging of osteomyelitis, Eur J Nucl Med, 22, 1043, 10.1007/BF00808418
Maurer, 1981, Utility of three-phase skeletal scintigraphy in suspected osteomyelitis: concise communication, J Nucl Med, 22, 941
Corstens, 1999, Nuclear medicine's role in infection and inflammation, Lancet, 354, 765, 10.1016/S0140-6736(99)06070-5
Verlooy, 1990, Tc-99m HM-PAO labelled leucocyte scanning for detection of infection in orthopedic surgery, Prog Clin Biol Res, 355, 181
Seabold, 1991, Postoperative bone marrow alterations: potential pitfalls in the diagnosis of osteomyelitis with In-111-labeled leukocyte scintigraphy, Radiology, 180, 741, 10.1148/radiology.180.3.1871288
King, 1990, Imaging of bone infection with labelled white blood cells: role of contemporaneous bone marrow imaging, Eur J Nucl Med, 17, 148, 10.1007/BF00811443
Love, 2001, Role of nuclear medicine in diagnosis of the infected joint replacement, Radiographics, 21, 1229, 10.1148/radiographics.21.5.g01se191229
Palestro, 1997, Radionuclide imaging in orthopedic infections, Semin Nucl Med, 27, 334, 10.1016/S0001-2998(97)80006-2
Gemmel, 2012, Prosthetic joint infections: radionuclide state-of-the-art imaging, Eur J Nucl Med Mol Imaging, 39, 892, 10.1007/s00259-012-2062-7
Bombardieri, 2003, Bone scintigraphy: procedure guidelines for tumour imaging, Eur J Nucl Med Mol Imaging, 30, BP99
De Vries, 2010, Guidelines for the labelling of leucocytes with (99m)Tc-HMPAO. Inflammation/Infection Taskgroup of the European Association of Nuclear Medicine, Eur J Nucl Med Mol Imaging, 37, 842, 10.1007/s00259-010-1394-4
Weon, 2000, Use of Tc-99m HMPAO leukocyte scans to evaluate bone infection: incremental value of additional SPECT images, Clin Nucl Med, 25, 519, 10.1097/00003072-200007000-00006
Copping, 1992, The role of 99Tcm-HMPAO white cell imaging in suspected orthopaedic infection, Br J Radiol, 65, 309, 10.1259/0007-1285-65-772-309
Sciuk, 1991, Comparison of technetium 99m polyclonal human immunoglobulin and technetium 99m monoclonal antibodies for imaging chronic osteomyelitis. First clinical results, Eur J Nucl Med, 18, 401, 10.1007/BF02258431
Magnuson, 1988, In-111-labeled leukocyte scintigraphy in suspected orthopedic prosthesis infection: comparison with other imaging modalities, Radiology, 168, 235, 10.1148/radiology.168.1.3380966
Palestro, 1991, Infected knee prosthesis: diagnosis with In-111 leukocyte, Tc-99m sulfur colloid, and Tc-99m MDP imaging, Radiology, 179, 645, 10.1148/radiology.179.3.2027967
Devillers, 1995, Technetium-99m hexamethylpropylene amine oxime leucocyte scintigraphy for the diagnosis of bone and joint infections: a retrospective study in 116 patients, Eur J Nucl Med, 22, 302, 10.1007/BF00941845
Moragas, 1991, 99Tcm-HMPAO leucocyte scintigraphy in the diagnosis of bone infection, Nucl Med Commun, 12, 417, 10.1097/00006231-199105000-00006
Segura, 2004, What is the role of bone scintigraphy in the diagnosis of infected joint prostheses?, Nucl Med Commun, 25, 527, 10.1097/00006231-200405000-00016
Larikka, 2001, Extended combined 99mTc-white blood cell and bone imaging improves the diagnostic accuracy in the detection of hip replacement infections, Eur J Nucl Med, 28, 288, 10.1007/s002590000463
Larikka, 2001, Improved method for detecting knee replacement infections based on extended combined 99mTc-white blood cell/bone imaging, Nucl Med Commun, 22, 1145, 10.1097/00006231-200110000-00015
Fernandez, 2008, 99mTc-HMPAO labelled white blood cell scintigraphy in patients with osteoarticular infection: the value of late images for diagnostic accuracy and interobserver reproducibility, Eur J Clin Microbiol Infect Dis, 27, 1239, 10.1007/s10096-008-0563-x
Erba, 2014, Image acquisition and interpretation criteria for 99mTc-HMPAO-labelled white blood cell scintigraphy: results of a multicentre study, Eur J Nucl Med Mol Imaging, 41, 615, 10.1007/s00259-013-2631-4
Filippi, 2006, Usefulness of hybrid SPECT/CT in 99mTc-HMPAO-labeled leukocyte scintigraphy for bone and joint infections, J Nucl Med, 47, 1908
Seabold, 1989, Detection of osteomyelitis at fracture nonunion sites: comparison of two scintigraphic methods, AJR Am J Roentgenol, 152, 1021, 10.2214/ajr.152.5.1021
Palestro, 1991, Radionuclide diagnosis of vertebral osteomyelitis: indium-111-leukocyte and technetium-99m-methylene diphosphonate bone scintigraphy, J Nucl Med, 32, 1861
Datz, 1994, Indium-111-labeled leukocytes for the detection of infection: current status, Semin Nucl Med, 24, 92, 10.1016/S0001-2998(05)80225-9
Datz, 1986, Effect of antibiotic therapy on the sensitivity of indium-111-labeled leukocyte scans, J Nucl Med, 27, 1849
Kolindou, 1996, In-111 WBC imaging of osteomyelitis in patients with underlying bone scan abnormalities, Clin Nucl Med, 21, 183, 10.1097/00003072-199603000-00001
Brown, 1994, The radiation dosimetry and normal value study of 99mTc-HMPAO-labeled leukocytes, Invest Radiol, 29, 443, 10.1097/00004424-199404000-00010
Schauwecker, 1988, Comparison of purified indium-111 granulocytes and indium-111 mixed leukocytes for imaging of infections, J Nucl Med, 29, 23
Galpérine, 2004, Cold bone defect on granulocytes labelled with technetium-99m-HMPAO scintigraphy: significance and usefulness for diagnosis and follow-up of osteoarticular infections, Scand J Infect Dis, 36, 209, 10.1080/00365540310018851