
International Journal of Energy and Water Resources
2522-0101
2538-3604
Cơ quản chủ quản: N/A
Lĩnh vực:
Các bài báo tiêu biểu
Hydrogeochemical evolution, water quality indices, irrigation suitability and pollution index of groundwater (PIG) around eastern Niger Delta, Nigeria
Tập 6 Số 3 - Trang 389-411 - 2022
Technology-oriented approach to quantitative assessment of water–energy–food nexus
Tập 4 Số 2 - Trang 189-197 - 2020
Assessment of the electricity generation, desalination and wastewater treatment capacity of a plant microbial desalination cell (PMDC)
Tập 3 Số 3 - Trang 213-218 - 2019
Vulnerability characterization for multi-carbonate aquifer systems in semiarid climate, case of Algerian–Tunisian transboundary basin
Tập 6 Số 1 - Trang 67-80 - 2022
Identification of waterbody status in Nigeria using predictive index assessment tools: a case study of Eme River, Umuahia, Nigeria
Tập 4 Số 3 - Trang 271-279 - 2020
Geo-hydraulic evaluation of aquifers of the Upper Imo River Basin, Southeastern Nigeria using Dar-Zarrouk parameters
Tập 5 Số 3 - Trang 259-275 - 2021
Unravelling the water-energy-economics-continuum of hydroelectricity in the face of climate change
- 2022
Mathematical modeling and study on the application of cross flow direct evaporative cooler under different indoor and outdoor environmental conditions
- 2020
Performance of a cross flow direct evaporative cooler under different indoor and outdoor conditions was investigated by a thermodynamic model and using finite difference scheme. Unlike the previous studies, the temperature variation of water film during the evaporation process was included among the modeling, and the error of the mathematical model to estimate the effectiveness of the cooler became lower than the error reported in the literature. To achieve the comprehensive results and evaluation of the applicability of the system under real conditions, the performance of the cooler in ambient temperatures of 25, 30, 35 and 40 °C, relative humidities of 10, 30, 50 and 70% and cooling demand of 1–5 kW for a building with air changes of 5, 10 and 15 per hour was investigated. Lastly, the study on the performance of the cooler in different Iranian provincial capitals showed that for air change of 15 per hour and cooling demand of 1 kW, the system could provide thermal comfort conditions in 24 provincial centers while for air change of 5 per hour and cooling load of 5 kW, this goal cannot be achieved in any centers. Moreover, comparing the water consumption of the coolers showed that the maximum and minimum daily water consumption was for Yazd in September and for Kermanshah on July, respectively. Investigation of the coefficient of performance of the system for air changes of 10 and 15 per hour revealed that Khoramabad and Bandar Abbas had the maximum and minimum coefficients of performance, respectively.