cobas 8000 Modular Analyzer Series Evaluated under Routine-like Conditions at 14 Sites in Australia, Europe, and the United States

SLAS Technology - Tập 18 - Trang 306-327 - 2013
Arnold von Eckardstein1, Hans Jürgen Roth2, Graham Jones3, Sharon Preston4, Thomas Szekeres5, Roland Imdahl6, Marc Conti7, Norbert Blanckaert8, Darren Jose9, Joachim Thiery10, Lisa Feldmann11, Nicolas von Ahsen12, Massimo Locatelli13, Jenni Kremastinou14, Albert Kunst15, Arnulf Hubbuch15, Margaret McGovern15
1Institut für Klinische Chemie, Universitätsspital Zürich, Zürich, Switzerland
2Labor Dr. Limbach und Kollegen, Heidelberg, Germany
3St Vincent’s Public Hospital, Sydney, Australia
4Huntsville Hospital, Huntsville, AL, USA
5Klinisches Institut für Medizinische und Chemische Labordiagnostik, AKH Wien, Vienna, Austria
6Labor Schottdorf MVZ GmbH, Augsburg, Germany
7CHU de Bicêtre, Le Kremlin-Bicêtre, France
8University Hospitals K.U., Leuven, Belgium
9Poole Hospital, NHS FoundationTrust, Poole, UK
10Universtitätsklinikum Leipzig, Leipzig, Germany
11Mid America Clinical Laboratories, Indianapolis, IN, USA
12Universitätsmedizin, Georg-August-Universität, Göttingen, Germany
13Laboraf–Diagnostica e Ricerca San Raffaele SpA, Milan, Italy
14Biomedicine (Bioiatriki), Athens, Greece
15Roche Diagnostics GmbH, Mannheim, Germany

Tài liệu tham khảo

Horowitz, 2005, MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory, J. Autom. Methods Manag. Chem., 1, 8, 10.1155/JAMMC.2005.8 Bieglmayer, 2004, Multicentre Evaluation of the E170 Module for MODULAR ANALYTICS, Clin. Chem. Lab. Med., 42, 1186, 10.1515/CCLM.2004.239 Mocarelli, 2008, Increasing Efficiency and Quality by Consolidation of Clinical Chemistry and Immunochemistry Systems with MODULAR ANALYTICS SWA, J. Autom. Methods Manag. Chem., 2008, 1, 10.1155/2008/498921 Van Gammeren, 2008, Cobas 6000 Performance with an Emphasis on Trueness Verification, Clin. Chem. Lab. Med., 46, 863, 10.1515/CCLM.2008.159 Stockmann, 2008, An Innovative Approach to Functionality Testing of Analysers in the Clinical Laboratory, J. Autom. Methods Manag. Chem., 2008, 183747, 10.1155/2008/183747 Kunst, A., Busse Grawitz, A., Engeldinger, W., et al. WinCAEv—A New Program Supporting Evaluations of Reagents and Analysers. Clin. Chim. Acta. 2005, 355S. Abstract WP6.04:361. Broughton, 1974, A Revised Scheme for the Evaluation of Automatic Instruments for Use in Clinical Chemistry, Ann. Clin. Biochem., 11, 207, 10.1177/000456327401100164 Peake, 2006, Measurements of Serum Creatinine—Current Status and Future Goals, Clin. Biochem. Rev., 27, 173 Bablok, 1995, Stockmann, W: An Alternative Approach to a System Evaluation in the Field, Quimica Clinica, 14, 239 Passing, 1983, A New Biometrical Procedure for Testing the Equality of Measurements from Two Different Analytical Methods, J. Clin. Chem. Clin. Biochem., 21, 709 Stockmann, 1993, Criteria of Practicability, 185