Wire-driven flexible manipulator with constrained spherical joints for minimally invasive surgery

Springer Science and Business Media LLC - Tập 14 - Trang 1365-1377 - 2019
Daekeun Ji1, Tae Hun Kang2, Seongbo Shim1, Seongpung Lee1, Jaesung Hong1
1Robotics Engineering Department, DGIST, Daegu, Republic of Korea
2Convergence Research Center for Collaborative Robots, DGIST, Daegu, Republic of Korea

Tóm tắt

One of the main factors that affect the rigidity of flexible robots is the twist deformation because of the external force exerted on the end effector. Another important factor that affects accuracy is the fact that such robots do not have a constant curvature. The conventional kinematic model assumes that the curvature is constant; however, in reality, it is not. To improve the rigidity and accuracy of flexible robots used in minimally invasive surgery via preventing the twist deformation while ensuring a constant curvature, we propose a novel flexible manipulator with ball-constrained spherical (BCS) joints and a spring. The BCS joints are used to prevent the twist deformation in the flexible robot. The joints have two degrees of freedom (DOFs), which limit the rotation about the axial direction. The rotation is limited because the ball that is inserted into a BCS joint can move only along the ball guide. To obtain a constant curvature, springs are installed among the BCS joints. The springs receive the uniform compression force generated among the joints, thus achieving a constant curvature. The proposed BCS joint is designed based on the diameter of the forceps, desired workspace, and desired bending angle. To evaluate the proposed mechanism, three experiments were performed using a 20-mm-diameter prototype consisting of 13 BCS joints with a two-DOF motion. The experimental results showed that the prototype can realize a constant curvature with a mean error of 0.21°, which can support up to 5 N with no apparent twist deformation. We developed a flexible manipulator with BCS joints for minimally invasive surgery. The proposed mechanism is anticipated to help prevent the twist deformation of the robot and realize a constant curvature. Accordingly, it is expected that rigidity is improved to ensure accuracy.

Tài liệu tham khảo

Bodner J, Wykypiel H, Wetscher G, Schmid T (2004) First experiences with the da Vinci™ operating robot in thoracic surgery. Eur J Cardio-thoracic Surg 25(5):844–851 Piccigallo M, Scarfogliero U, Quaglia C, Petroni G, Valdastri P, Menciassi A, Dario P (2010) Design of a novel bimanual robotic system for single-port laparoscopy. IEEE/ASME Trans Mechatron 15(6):871–878 Lee H, Choi Y, Yi BJ (2012) Stackable 4-bar manipulators for single port access surgery. IEEE/ASME Trans Mechatron 17(1):157–166 Cheon B, Gezgin E, Ji DK, Tomikawa M, Hashizume M, Kim HJ, Hong J (2014) A single port laparoscopic surgery robot with high force transmission and a large workspace. Surg Endosc 28(9):2719–2729 Asari VK, Kumar S, Kassim IM (2000) A fully autonomous microrobotic endoscopy system. J Intell Robot Syst 28(4):325–341 Bailly Y, Amirat Y, Fried G (2011) Modeling and control of a continuum style microrobot for endovascular surgery. IEEE Trans Robot 27(5):1024–1030 Simaan N (2005) Snake-like units using flexible backbones and actuation redundancy for enhanced miniaturization. In: Proceedings of 2005 IEEE international conference robotics and automation, Barcelona, pp 3012–3017 Chen G, Fu L, Pham MT, Redarce T (2013) Characterization and modeling of a pneumatic actuator for a soft continuum robot. In: IEEE international conference mechatronics automation, Takamatsu, pp 243–248 Yoshimitsu K, Kato T, Song SE, Hata N (2014) A novel four-wire-driven robotic catheter for radio-frequency ablation treatment. Int J Comput Assist Radiol Surg 9(5):867–874 Amanov E, Nguyen TD, Burgner-Kahrs J (2015) Additive manufacturing of patient-specific tubular continuum manipulators. In: Webster RJ, Yaniv ZR (eds) Medical imaging 2015: image-guided procedures, robotic interventions, and modeling, vol 9415, Florida, pp 94151P. https://doi.org/10.1117/12.2081999 Ding J, Goldman RE, Xu K, Allen PK, Fowler DL, Simaan N (2013) Design and coordination kinematics of an insertable robotic effectors platform for single port access surgery. IEEE/ASME Trans Mechatron 18(5):1612–1624 Xu K, Zhao J, Fu M (2015) Development of the SJTU unfoldable robotic system (SURS) for single port laparoscopy. IEEE/ASME Trans Mechatron 20(5):2133–2145 Kato T, Okumura I, Kose H, Takagi K, Hata N (2016) Tendon-driven continuum robot for neuroendoscopy: validation of extended kinematic mapping for hysteresis operation. Int J Comput Assist Radiol Surg 11(4):589–602 Dupont PE, Lock J, Itkowitz B, Butler E (2010) Design and control of concentric-tube robots. IEEE Trans Robot 26(2):209–225 Burgner-Kahrs J, Rucker DC, Choset H (2015) Continuum robots for medical applications: a survey. IEEE Trans Robot 31(6):1261–1280 Kim YJ, Cheng SS, Desai JP (2018) Active stiffness tuning of a spring-based continuum robot for MRI-guided neurosurgery. IEEE Trans Robot 34(1):18–28 Wang J, Wang S, Li J, Ren X, Briggs RM (2018) Development of a novel robotic platform with controllable stiffness manipulation arms for laparoscopic single-site surgery (LESS). Int J Med Robot Comput Assist Surg 14(1):e1838 Xu K, Fu M, Zhao J (2014) An experimental kinestatic comparison between continuum manipulators with structural variations. In: IEEE international conference robotics automation, China, pp 3258–3264 Dong X, Raffles M, Cobos-Guzman S, Axinte D, Kell J (2016) A novel continuum robot using twin-pivot compliant joints: design, modeling, and validation. J Mech Robot 8(2):021010 Shim SB, Kang TH, Ji DK, Choi HS, Joung SH, Hong JS (2016) An all-joint control master device for single port laparoscopic surgery robots. Int J Comput Assist Radiol Surg 11(8):1547–1557 Hannan MW, Walker ID (2001) Analysis and experiments with an elephant’s trunk robot. Adv Robot 15(8):847–858 Shi C, Luo X, Qi X, Li T, Song S, Najdovski Z, Fukuda T (2017) Shape sensing techniques for continuum robots in minimally invasive surgery: a survey. IEEE Trans Biomed Eng 64(8):1665–1678 Rone WS, Ben-Tzvi P (2014) Mechanics modeling of multisegment rod-driven continuum robots. J Mech Robot 6(4):041006 Webster RJ III, Romano JM, Cowan NJ (2009) Mechanics of precurved-tube continuum robots. IEEE Trans Robot 25(1):67–78 Rucker DC, Webster RJ III (2011) Statics and dynamics of continuum robots with general tendon routing and external loading. IEEE Trans Robot 27(6):1033–1044 Rone WS, Ben-Tzvi P (2014) Continuum robot dynamics utilizing the principle of virtual power. IEEE Trans Robot 30(1):275–287 Jones BA, Walker ID (2006) Kinematics for multisection continuum robots. IEEE Trans Robot 22(1):43–55 Li Z, Du R, Yu H, Ren H (2014) Statics modeling of an underactuated wire-driven flexible robotic arm. In: IEEE international conference biomedical robotics biomechatronics, Brazil, pp 326–331 Suh JW, Kim KY, Jeong JW, Lee JJ (2015) Design considerations for a hyper-redundant pulleyless rolling joint with elastic fixtures. IEEE/ASME Trans Mechatron 20(6):2841–2852 Nguyen TD, Burgner-Kahrs J (2015) A tendon-driven continuum robot with extensible sections. In: IEEE/RSJ international conference on intelligent robots and systems, Hamburg, pp 2130–2135 Autorino R, Stein RJ, Lima E, Damiano R, Khanna R, Haber GP, White MA, Kaouk JH (2010) Current status and future perspectives in laparoendoscopic single-site and natural orifice transluminal endoscopic urological surgery. Int J Urol 17(5):410–431 Blanc L, Delchambre A, Lambert P (2017) Flexible medical devices: review of controllable stiffness solutions. Actuators 6(3):23 Morimoto TK, Hawkes EW, Okamura AM (2017) Design of a compact actuation and control system for flexible medical robots. IEEE Robot Autom Lett 2(3):1579–1585 Patel N, Seneci CA, Shang J, Leibrandt K, Yang GZ, Darzi A, Teare J (2015) Evaluation of a novel flexible snake robot for endoluminal surgery. Surg Endosc 29(11):3349–3355 Wang X, Meng MQH (2012) Robotics for natural orifice transluminal endoscopic surgery: a review. J Robot. https://doi.org/10.1155/2012/512616 Patel N, Seneci C, Yang GZ, Darzi A, Teare J (2014) Flexible platforms for natural orifice transluminal and endoluminal surgery. Endosc Int Open 2(02):117–123 Sarli N, Simaan N (2017) Minimal visual occlusion redundancy resolution of continuum robots in confined spaces. In: IEEE international conference on intelligent robots and systems, Vancouver, pp 24–28 Evangeliou N, Tzes A (2016) Development of an SMA actuated redundant robotic platform for minimally invasive surgery. In: IEEE international conference biomedical robotics and biomechatronics, Utown, pp 26–29 Georgilas IP, Tourassis VD (2009) A novel biologically inspired flexible robotic mechanism for industrial applications. In: IEEE/ASME international conference, Singapore, pp 1504–1509 Seow CM, Chin WJ, Nelson CA, Nakamura A, Farritor SM, Oleynikov D (2013) Articulated manipulator with multiple instruments for natural orifice transluminal endoscopic surgery. J Med Devices 7(4):041004 Keller S, Gordon A (2011) Equivalent stress and strain distribution in helical compression springs subjected to bending. J Strain Anal Eng Des 46(6):405–415 Webster RJ III, Jones BA (2010) Design and kinematic modeling of constant curvature continuum robot: a review. Int J Robot Res 29(13):1661–1683 Malekzadeh P, Karami G (2003) Out-of-plane static analysis of circular arches by DQM. Int J Solid Struct 40(23):6527–6545