Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference?

International Orthopaedics - Tập 46 - Trang 2165-2176 - 2022
Mohamed Abdel-Wahed1, Ahmed Abdel-Zaher Khater2, Mahmoud Ahmed El-Desouky1
1Department of Trauma and Orthopedics, Faculty of Medicine, Cairo University, Cairo, Egypt
2Ahmed Maher Teaching Hospital, Cairo, Egypt

Tóm tắt

Two different locking plate designs are now being used for volar plating of the distal radius fractures based on the freedom of screw direction; the fixed-angle, and the variable-angle (polyaxial) plates. We investigated the clinical and radiographic outcomes of both designs. We reviewed 96 patients with 113 unstable distal radius fractures that were operated on with volar locking plates. The patients’ mean age was 41 years. Fixed-angle volar locking plates were utilized in 65 fractures and variable-angle volar locking plates in 48 fractures through modified Henry approach or extended carpal tunnel approach. Full clinical and radiographic evaluation was done for all patients with a mean follow-up of 14 months. All patients had acceptable clinical and radiographic parameters. The overall functional results (Mayo score, Quick Disability of Arm, Shoulder, and Hand (Q-DASH) score, Range of motion (ROM), and grip strength) were in favor of the variable-angle plate. The radiographic parameters were better with the variable-angle group. The variable-angle group recorded less operative time but more mean image intensifier exposure time. There were two cases of flexor tendon rupture with the fixed-angle group. Fixation with the fixed-angle system needed K-wire augmentation more than the variable-angle group. There was a positive correlation between hand dominance and the final score. Distal radius volar locking plates yield satisfactory results comparable among different designs. In our series, the variable-angle system showed slightly better function and radiographic outcomes. Supplementary K-wires were needed more frequently with the fixed-angle system.

Tài liệu tham khảo

Matzon JL, Beredjiklian P (2009) Gowned and gloved orthopedics, introduction to common procedures. Chapter 11 (Open Reduction and Internal Fixation of Distal Radius Fractures), 104–112 Obert L, Rey PB, Uhring J, Gasse N, Rochet S, Lepage D, Serre A, Garbuio P (2013) Fixation of distal radius fractures in adults: a review. Orthop Traumatol Surg Res 99(2):216–234. https://doi.org/10.1016/j.otsr.2012.03.023 Smith DW, Henry MH (2005) Volar fixed-angle plating of the distal radius. J Am Acad Orthop Surg 13(1):28–36. https://doi.org/10.5435/00124635-200501000-00005 Osada D, Viegas SF, Shah MA, Morris RP, Patterson RM (2003) Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg 28(1):94–104. https://doi.org/10.1053/jhsu.2003.50016 Gogna P, Selhi HS, Singla R, Devgan A, Magu NK, Mahindra P, Yamin M (2013) Dorsally comminuted fractures of the distal end of the radius: osteosynthesis with volar fixed angle locking plates. ISRN Orthop 2013:131757. https://doi.org/10.1155/2013/131757 Orbay J, Badia A, Khoury RK, Gonzalez E, Indriago I (2004) Volar fixed-angle fixation of distal radius fractures: the DVR plate. Tech Hand Up Extrem Surg 8(3):142–148. https://doi.org/10.1097/01.bth.0000126570.82826.0a Martineau D, Shorez J, Beran C, Dass AG, Atkinson P (2014) Biomechanical performance of variable and fixed angle locked volar plates for the dorsally comminuted distal radius. Iowa Orthop J 34:123–128 Park JH, Hagopian J, Ilyas AM (2010) Variable-angle locking screw volar plating of distal radius fractures. Hand Clin 26(3):373–vi. https://doi.org/10.1016/j.hcl.2010.04.003 Khatri K, Sharma V, Farooque K, Tiwari V (2016) Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes. Arch Trauma Res 5(2):e25174. https://doi.org/10.5812/atr.25174 Ilyas AM (2011) Surgical approaches to the distal radius. Hand (New York, N.Y.) 6(1):8–17. https://doi.org/10.1007/s11552-010-9281-9 Rausch, S., Schlonski, O., Klos, K., Gras, F., Gueorguiev, B., Hofmann, G. O., & Mückley, T. (2013). Volar versus dorsal latest-generation variable-angle locking plates for the fixation of AO type 23C 2.1 distal radius fractures: A biomechanical study in cadavers. Injury 44(4):523–526. https://doi.org/10.1016/j.injury.2012.08.048 Rausch S, Klos K, Stephan H, Hoffmeier K, Gras F, Windolf M, Gueorguiev B, Hofmann GO, Mückley T (2011) Evaluation of a polyaxial angle-stable volar plate in a distal radius C-fracture model: A biomechanical study. Injury 42(11):1248–1252. https://doi.org/10.1016/j.injury.2010.12.005 Al-Mouazzen L, Chou DT, Kyriakopoulos G, Hambidge J (2014) Polyaxial versus uniaxial volar locking plate for distal radial fractures. J Orthop Surg (Hong Kong) 22(1):9–12. https://doi.org/10.1177/230949901402200105 Mehrzad R, Kim DC (2016) Complication Rate Comparing Variable Angle Distal Locking Plate to Fixed Angle Plate Fixation of Distal Radius Fractures. Ann Plast Surg 77(6):623–625. https://doi.org/10.1097/SAP.0000000000000850 Marlow WJ, Singhal R, Dheerendra S, Ralte P, Fischer J, Waseem M (2012) Distal radius volar locking plates: does a variable angle locking system confer a clinical advantage? Acta Orthop Belg 78(3):309–316 Cha SD, Jai P, Hyung SK, Soo-Tae C, Jeong-Hyun Y, Joo-Hak K et al (2012) Comparative analysis of the results of fixed-angle versus variable-angle volar locking plate for distal radius fracture fixation. J Korean Fract Soc 25:197 Nishiwaki M, Terasaka Y, Kiyota Y, Inaba N, Koyanagi T, Horiuchi Y (2021) A Prospective Randomized Comparison of Variable-Angle and Fixed-Angle Volar Locking Plating for Intra-Articular Distal Radius Fractures. J Hand Surg 46(7):584–593. https://doi.org/10.1016/j.jhsa.2021.03.014 Kwok IH, Leung F, Yuen G (2011) Assessing results after distal radius fracture treatment: a comparison of objective and subjective tools. Geriatr Orthop Surg Rehab 2(4):155–160. https://doi.org/10.1177/2151458511422701 Plant CE, Parsons NR, Costa ML (2017) Do radiological and functional outcomes correlate for fractures of the distal radius? Bone Joint J 99-B(3):376–382. https://doi.org/10.1302/0301-620X.99B3.35819 Zenke Y, Sakai A, Oshige T, Moritani S, Nakamura T (2009) The effect of an associated ulnar styloid fracture on the outcome after fixation of a fracture of the distal radius. J Bone Joint Surg Br 91(1):102–107. https://doi.org/10.1302/0301-620X.91B1.21026 Brenner H, Arndt V (2004) Epidemiology in aging research. Exp Gerontol 39(5):679–686. https://doi.org/10.1016/j.exger.2004.02.006 Schmelzer-Schmied N, Wieloch P, Martini AK, Daecke W (2009) Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly. Int Orthop 33(3):773–778. https://doi.org/10.1007/s00264-007-0504-9 DeGeorge BR, Jr, Van Houten HK, Mwangi R, Sangaralingham LR, Larson AN, Kakar S (2020) Outcomes and Complications in the Management of Distal Radial Fractures in the Elderly. J Bone Joint Surg Am 102(1):37–44. https://doi.org/10.2106/JBJS.18.00561 Asadollahi S, Keith PP (2013) Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol 14(4):227–234. https://doi.org/10.1007/s10195-013-0245-z Soong M, Earp BE, Bishop G, Leung A, Blazar P (2011) Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am 93(4):328–335. https://doi.org/10.2106/JBJS.J.00193 Casaletto JA, Machin D, Leung R, Brown DJ (2009) Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur 34(4):471–474. https://doi.org/10.1177/1753193408100964