Trends in Blood Culture Contamination: A College of American Pathologists Q-Tracks Study of 356 Institutions

Archives of Pathology and Laboratory Medicine - Tập 129 Số 10 - Trang 1222-1225 - 2005
Leonas G. Bekeris1,2,3, Joseph A. Tworek1,2,3, Molly K. Walsh1,2,3, Paul N. Valenstein1,2,3
1College of American Pathologists, Northfield, Ill (Dr Walsh)
2From Phoenixville Hospital Laboratory, Phoenixville, Pa (Dr Bekeris)
3From Phoenixville Hospital Laboratory, Phoenixville, Pa (Dr Bekeris); Pathology and Laboratory Management Associates, Ann Arbor, Mich (Drs Tworek and Valenstein); and College of American Pathologists, Northfield, Ill (Dr Walsh)

Tóm tắt

Abstract Context.—Blood culture contamination extends hospital stays and increases the cost of care. Objectives.—To measure blood culture contamination rates in a large number of institutions over time and to elucidate practice patterns and demographic factors associated with sustained reduction in contamination rates. Design.—Longitudinal cohort study of 356 clinical laboratories that provided quarterly data about blood culture results, using a uniform definition of contamination. Mixed linear model analysis of the 1999 through 2003 data set. Results.—Blood culture contamination was significantly higher in institutions that used nonlaboratory personnel to collect blood (P = .03) and significantly lower in facilities that used a dedicated phlebotomy team (P < .001). Higher volume of blood collection was significantly associated with lower contamination rates (P < .001). Continued participation in the Q-Tracks monitoring program was associated with significant and progressive reduction in contamination rates. By the fifth year of participation, the median institution had reduced its blood culture contamination rate by 0.67% (P < .001). Conclusions.—Institutions that use decentralized patient-centered personnel rather than dedicated phlebotomy teams to collect blood cultures experience significantly higher contamination rates. Long-term monitoring of contamination is associated with sustained improvement in performance.

Từ khóa


Tài liệu tham khảo

Mirrett, 2001, Relevance of the number of positive bottles in determining clinical significance of coagulase-negative staphylococci in blood cultures., J Clin Microbiol, 39, 3279, 10.1128/JCM.39.9.3279-3281.2001

Weinstein, 2003, Blood culture contamination: persisting problems and partial progress., J Clin Microbiol, 41, 2275, 10.1128/JCM.41.6.2275-2278.2003

Bates, 1991, Contaminant blood cultures and resource utilization: the true consequences of false-positive results., JAMA, 265, 365, 10.1001/jama.1991.03460030071031

Souvenir, 1998, Blood cultures positive for coagulase-negative staphylococci: antisepsis, pseudobacteremia, and therapy of patients., J Clin Microbiol, 36, 1923, 10.1128/JCM.36.7.1923-1926.1998

Nordberg, 2003, Contamination rates of blood cultures obtained by dedicated phlebotomy vs intravenous catheter., JAMA, 289, 726, 10.1001/jama.289.6.726

Strand, 1993, Effect of iodophor vs iodine tincture skin preparation on blood culture contamination rate., JAMA, 269, 1004, 10.1001/jama.1993.03500080052031

Mimoz, 1999, Chlorhexidine compared with povidone-iodine as skin preparation before blood culture: a randomized, controlled trial., Ann Intern Med, 131, 843, 10.7326/0003-4819-131-11-199912070-00006

Spitalnic, 1995, The significance of changing needles when inoculating blood cultures: a meta-analysis., Clin Infect Dis, 21, 1003, 10.1093/clinids/21.5.1103

Schifman, 1993, The effect of skin disinfection materials on reducing blood culture contamination., Am J Clin Pathol, 99, 536, 10.1093/ajcp/99.5.536

Surdulescu, 1998, Phlebotomy teams reduce blood culture contamination rate and save money., Clin Perform Qual Health Care, 6, 60

Weinbaum, 1997, Doing it right the first time: quality improvement and the contaminant blood culture., J Clin Microbiol, 35, 563, 10.1128/JCM.35.3.563-565.1997

Gibb, 1997, Reduction in blood culture contamination rate by feedback to phlebotomists., Arch Pathol Lab Med, 121, 503

Schifman, 1998, Blood culture contamination: a College of American Pathologists Q-Probes study involving 640 institutions and 497 134 specimens from adult patients., Arch Pathol Lab Med, 122, 216

Weinstein, 2003, Blood culture contamination: persisting problems and partial progress., J Clin Microbiol, 41, 2275, 10.1128/JCM.41.6.2275-2278.2003

Weinstein, 1997, The clinical significance of positive blood cultures in the 1990s: a prospective comprehensive evaluation of the microbiology, epidemiology, and outcome of bacteremia and fungemia in adults., Clin Infect Dis, 24, 584, 10.1093/clind/24.4.584

Smith, 1995, Comparison of BACTEC 9240 and BacT/Alert blood culture systems in an adult hospital., J Clin Microbiol, 33, 1905, 10.1128/JCM.33.7.1905-1908.1995

Bryant, 1987, Reliability of blood cultures collected from intravascular catheter versus venipuncture., Am J Clin Pathol, 88, 113, 10.1093/ajcp/88.1.113

Valenstein, Blood CultureContamination: 2003 Q-Tracks Annual Summary Report.

Aronson, 1987, Blood cultures., Ann Intern Med, 106, 246, 10.7326/0003-4819-106-2-246

Reimer, 1997, Update on the detection of bacteremia and fungemia., Clin Microbiol Rev, 10, 444, 10.1128/CMR.10.3.444

Zarbo, 2002, Q-Tracks: a College of American Pathologists program of continuous laboratory monitoring and longitudinal performance tracking., Arch Pathol Lab Med, 126, 1036, 10.5858/2002-126-1036-QT