Three‐dimensional whole‐heart T<sub>2</sub> mapping at 3T

Magnetic Resonance in Medicine - Tập 74 Số 3 - Trang 803-816 - 2015
Haiyan Ding1,2, L. Fernandez-de-Manuel3,2, Michael Schär4,5, Karl H. Schuleri6, Henry R. Halperin6, Le He1, Muz Zviman6, Roy Beinart7,8, Daniel A. Herzka2
1Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, People's Republic of China
2Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, USA
3Biomedical Image Technologies Laboratory ETSI Telecomunicación, Universidad Politécnica de Madrid, and CIBER‐BBN Madrid Spain
4Philips Healthcare, Cleveland, Ohio, USA
5Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine, Baltimore, Maryland, USA.
6Department of Medicine - Cardiology, Johns Hopkins School of Medicine, Baltimore, Maryland, USA
7Department of Medicine, Cardiology; Johns Hopkins School of Medicine; Baltimore Maryland USA
8Heart Institute, Sheba Medical Center, Tel Aviv University, Ramat Gan, Israel

Tóm tắt

PurposeDetecting variations in myocardial water content with T2 mapping is superior to conventional T2‐weighted MRI since quantification enables direct observation of complicated pathology. Most commonly used T2 mapping techniques are limited in achievable spatial and/or temporal resolution, both of which reduce accuracy due to partial‐volume averaging and misregistration between images. The goal of this study was to validate a novel free breathing T2 mapping sequence that overcomes these limitations.MethodsThe proposed technique was made insensitive to heart rate variability through the use of a saturation prepulse to reset magnetization every heartbeat. Respiratory navigator‐gated, differentially T2‐weighted volumes were interleaved per heartbeat, guaranteeing registered images and robust voxel‐by‐voxel T2 maps. Free breathing acquisitions removed limits on spatial resolution and allowed short diastolic windows. Accuracy was quantified with simulations and phantoms.ResultsHomogeneous three‐dimensional (3D) T2 maps were obtained from normal human subjects and swine. Normal human and swine left ventricular T2 values were 42.3 ± 4.0 and 43.5 ± 4.3 ms, respectively. The T2 value for edematous myocardium obtained from a swine model of acute myocardial infarction was 59.1 ± 7.1 ms.ConclusionFree‐breathing accurate 3D T2 mapping is feasible and may be applicable in myocardial assessment in lieu of current clinical black blood, T2‐weighted techniques. Magn Reson Med 74:803–816, 2015. © 2014 Wiley Periodicals, Inc.

Từ khóa


Tài liệu tham khảo

10.1016/j.jacc.2004.11.069

10.1097/00004728-200209000-00017

10.1007/s10554-009-9515-5

10.1148/radiol.12112491

10.1093/eurheartj/ehq481

10.1038/nrcardio.2010.28

10.1161/CIRCULATIONAHA.105.576025

10.1002/jmri.21028

10.1186/1532-429X-11-7

10.1002/mrm.25258

10.1148/radiology.199.1.8633172

10.1002/mrm.21215

10.1186/1532-429X-11-56

10.1016/j.jcmg.2013.05.005

10.1016/j.jcmg.2010.09.023

10.1161/CIRCIMAGING.111.971101

10.1161/CIRCIMAGING.111.967836

10.1002/mrm.22972

10.1016/j.jcmg.2012.01.016

10.1186/1532-429X-15-27

10.1007/BF02668182

10.1002/mrm.1910330515

10.1002/mrm.20835

10.1002/jmri.21361

10.1148/radiology.198.1.8539406

10.1002/mrm.24139

10.1002/mrm.23153

10.1002/mrm.25124

10.1002/mrm.24231

10.1148/radiology.205.1.9314975

10.1002/mrm.22128

10.1081/JCMR-120038086

10.1002/mrm.22234

HerzkaDA DingH SchärM.Improvement in B1+ Homogeneity of 3T Cardiac MRI in Swine with Dual‐Source Parallel RF Excitation. In Proceedings of the 21st Annual Meeting of ISMRM Salt Lake City Utah USA 2013. p.72.

Ashman R, 1945, Essentials of electrocardiography: for the student and practitioner of medicine, 162

10.1186/1532-429X-15-53

10.1063/1.1684482

10.1038/nm1503

10.1002/mrm.10051

LeeS SchärM ZvimanM Sena‐WeltinV HarouniA KozerkeS McVeighE HalperinH HerzkaD.Free breathing independent respiratory navigator‐gated imaging: concurrent PSIR and T2‐weighted 3D imaging of the left ventricle. In Proceedings of the 19th Annual Meeting of ISMRM Montreal Canada 2011. p19.

Scientific Computing and Imaging Institute (SCI).“Seg3D” Volumetric image segmentation and visualization. Version 2.1.4.http://www.sci.utah.edu/cibc‐software/seg3d.html. Updated February 24 2012. Accessed August 10 2012.

10.1109/MCG.2007.323435

10.1161/hc0402.102975

10.1016/j.jcmg.2012.06.010

10.1002/jmri.21851

10.1186/1532-429X-14-68

10.1161/01.CIR.86.3.1018

10.1002/mrm.22855

10.1002/mrm.10467

10.1002/mrm.21208

10.1002/jmri.21652

10.1002/mrm.21071

10.1002/mrm.22483

10.1148/radiol.11110347

10.1002/mrm.22756

10.1002/mrm.23128

10.1002/mrm.21423