Three-dimensional computational model of a blood oxygenator reconstructed from micro-CT scans
Tài liệu tham khảo
ANSYS Inc. ®, Ansys academic research – fluent. Simulation-Driven Product Development. URL http://www.ansys.com/. 2013.
Berggren, 1964
Bhavsar, 2011, Numerical modeling of anisotropic fiber bundle behavior in oxygenators, Artif Organs, 35, 1095, 10.1111/j.1525-1594.2011.01365.x
Chatburn, 2012, Determining the basis for a taxonomy of mechanical ventilation, Respir Care, 57, 514
Gartner, 2000, Modeling flow effects on thrombotic deposition in a membrane oxygenator, Artif Organs, 24, 29, 10.1046/j.1525-1594.2000.06384.x
GOV.UK, Medicines & healthcare products regulatory agency UK, Online, page visited 2016-09, 2016, https://www.gov.uk/government/organisations/medicines-and-healthcare-products-regulatory-agency.
Haworth, 2003, The development of the modern oxygenator, Ann Thoracic Surg, 76, S2216, 10.1016/j.athoracsur.2003.09.012
Hormes, 2011, A validated cfd model to predict O2 and CO2 transfer within hollow fiber membrane oxygenators, Int J Artif Organs, 34, 317, 10.5301/IJAO.2011.6494
Khanafer, 2012, The role of porous media in modeling fluid flow within hollow fiber membranes of the total artificial lung, J PorousMedia, 15, 113, 10.1615/JPorMedia.v15.i2.20
Low, 2016, Pore-scale modeling of non-Newtonian shear-thinning fluids in blood oxygenator design, J Biomech Eng–Trans ASME, 138, 10.1115/1.4032801
Marcinkowska-Gapińska, 2007, Comparison of three rheological models of shear flow behavior studied on blood samples from post-infarction patients, Med Biol Eng Comput, 45, 837, 10.1007/s11517-007-0236-4
Mazaheri, 2006, Uniformity of the fluid flow velocities within hollow fiber membranes of blood oxygenation devices, Artif Organs, 30, 10, 10.1111/j.1525-1594.2006.00150.x
Membrana GmbH, Oxyplus, Internet, 2013, http://www.membrana.com/healthcare/products/blood-oxygenation-products/oxyplus.
NHS. National health service. Chronic obstructive pulmonary disease health (copd).2013. Online, page visited August 2013, page last updated February 2013. http://www.nhsinform.co.uk/health-library/articles/c/chronic-obstructive-pulmonary-disease/introduction.
Pelosi, 2014, Computational evaluation of the thrombogenic potential of a hollow-fiber oxygenator with integrated heat exchanger during extracorporeal circulation, Biomech Model Mechanobiol, 13, 349, 10.1007/s10237-012-0445-0
Taskin, 2010, Micro-scale modeling of flow and oxygen transfer in hollow-fiber membrane bundle, J Membrane Sci, 362, 172, 10.1016/j.memsci.2010.06.034
WBS The Welsh blood service covers the whole of wales collecting voluntary, non-remunerated blood donations from the general public. Online, page visited 2016-09. URL https://www.welsh-blood.org.uk/about-us/; 2016.