The feasibility of a modified shoe for multi-segment foot motion analysis: a preliminary study
Tóm tắt
The majority of multi-segment kinematic foot studies have been limited to barefoot conditions, because shod conditions have the potential for confounding surface-mounted markers. The aim of this study was to investigate whether a shoe modified with a webbed upper can accommodate multi-segment foot marker sets without compromising kinematic measurements under barefoot and shod conditions. Thirty participants (15 controls and 15 participants with midfoot pain) underwent gait analysis in two conditions; barefoot and wearing a shoe (shod) in a random order. The shod condition employed a modified shoe (rubber plimsoll) with a webbed upper, allowing skin mounted reflective markers to be visualised through slits in the webbed material. Three dimensional foot kinematics were captured using the Oxford multi-segment foot model whilst participants walked at a self-selected speed. The foot pain group showed greater hindfoot eversion and less hindfoot dorsiflexion than controls in the barefoot condition and these differences were maintained when measured in the shod condition. Differences between the foot pain and control participants were also observed for walking speed in the barefoot and in the shod conditions. No significant differences between foot pain and control groups were demonstrated at the forefoot in either condition. Subtle differences between pain and control groups, which were found during barefoot walking are retained when wearing the modified shoe. The novel properties of the modified shoe offers a potential solution for the use of passive infrared based motion analysis for shod applications, for instance to investigate the kinematic effect of foot orthoses.
Tài liệu tham khảo
Deschamps K, Staes F, Roosen P, Nobels F, Desloovere K, Bruyninckx H, et al. Body of evidence supporting the clinical use of 3D multisegment foot models: a systematic review. Gait Posture. 2011;33(3):338–49.
Genova JM, Gross MT. Effect of foot orthotics on calcaneal eversion during standing and treadmill walking for subjects with abnormal pronation. J Orthop Sports Phys Ther. 2000;30(11):664–75.
Ritchie C, Paterson K, Bryant AL, Bartold S, Clark RA. The effects of enhanced plantar sensory feedback and foot orthoses on midfoot kinematics and lower leg neuromuscular activation. Gait Posture. 2011;33(4):576–81.
Eslami M, Begon M, Farahpour N, Allard P. Forefoot-rearfoot coupling patterns and tibial internal rotation during stance phase of barefoot versus shod running. Clin Biomech. 2007;22(1):74–80.
Morio C, Lake MJ, Gueguen N, Rao G, Baly L. The influence of footwear on foot motion during walking and running. J Biomech. 2009;42(13):2081–88.
Arnold JB, Bishop C. Quantifying foot kinematics inside athletic footwear: a review. Footwear Sci. 2013;5(1):55–62.
Rupérez M, Monserrat C, Alcañiz M. Simulation of the deformation of materials in shoe uppers in gait. Force distribution using finite elements. Int J Interact Des Manuf. 2008;2(2):59–68.
Shultz R, Jenkyn T. Determining the maximum diameter for holes in the shoe without compromising shoe integrity when using a multi-segment foot model. Medl Eng Phys. 2011;34(1):118–22.
Wolf S, Simon J, Patikas D, Schuster W, Armbrust P, Doderlein L. Foot motion in children shoes - A comparison of barefoot walking with shod walking in conventional and flexible shoes. Gait Posture. 2008;27(1):51–9.
Zhang X, Paquette MR, Zhang S. A comparison of gait biomechanics of flip-flops, sandals, barefoot and shoes. J Foot Ankle Res. 2013;6:45.
Wegener C, Hunt AE, Vanwanseele B, Burns J, Smith RM. Effect of children’s shoes on gait: a systematic review and meta-analysis. J Foot Ankle Res. 2011;4:3.
Stebbins J, Harrington M, Thompson N, Zavatsky A, Theologis T. Repeatability of a model for measuring multi-segment foot kinematics in children. Gait Posture. 2006;23(4):401–10.
Yung-Hui L, Wei-Hsien H. Effects of shoe inserts and heel height on foot pressure, impact force, and perceived comfort during walking. App Ergon. 2005;36(3):355–62.
Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng. 1983;105(2):136–44.
Levinger P, Murley GS, Barton CJ, Cotchett MP, McSweeney SR, Menz HB. A comparison of foot kinematics in people with normal-and flat-arched feet using the Oxford Foot Model. Gait Posture. 2010;32(4):519–23.
Wright CJ, Arnold BL, Coffey TG, Pidcoe PE. Repeatability of the modified Oxford foot model during gait in healthy adults. Gait Posture. 2011;33(1):108–12.
Redmond A, Crosbie J, Ouvrier R. Development and validation of a novel rating system for scoring standing foot posture: The Foot Posture Index. Clin Biomech. 2006;21(1):89–98.
Houck JR, Tome JM, Nawoczenski DA. Subtalar neutral position as an offset for a kinematic model of the foot during walking. Gait Posture. 2008;28(1):29–37.
Woltring HJ. On optimal smoothing and derivative estimation from noisy displacement data in biomechanics. Hum Mov Sci. 1985;4(3):229–45.
Barn R, Rafferty D, Turner DE, Woodburn J. Reliability study of tibialis posterior and selected leg muscle EMG and multi-segment foot kinematics in rheumatoid arthritis associated pes planovalgus. Gait Posture. 2012;36(3):567–71.
Diss CE. The reliability of kinetic and kinematic variables used to analyse normal running gait. Gait Posture. 2001;14(2):98–103.
Bartlett R, Wheat J, Robins M. Is movement variability important for sports biomechanists? Sports Biomech. 2007;6(2):224–43.
Kadaba M, Ramakrishnan H, Wootten M, Gainey J, Gorton G, Cochran G. Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait. J Orthop Rese. 1989;7(6):849–60.
Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86(2):420–28.
Chen SJ, Mukul M, Chou LS. Soft-tissue movement at the foot during the stance phase of walking. J Am Podiatr Med Assoc. 2011;101(1):25–34.
Leardini A, Chiari L, Della Croce U, Cappozzo A. Human movement analysis using stereophotogrammetry: Part 3. Soft tissue artifact assessment and compensation. Gait Posture. 2005;21(2):212–25.
Halstead J, Chapman GJ, Gray JC, Grainger AJ, Brown S, Wilkins RA et al. Foot orthoses in the treatment of symptomatic midfoot osteoarthritis using clinical and biomechanical outcomes: a randomised feasibility study. Clini Rheumatol. 2015: doi:10.1007/s10067-015-2946-6
Khazzam M, Long JT, Marks RM, Harris GF. Kinematic changes of the foot and ankle in patients with systemic rheumatoid arthritis and forefoot deformity. J Orthop Res. 2007;25(3):319–29.
Stacoff A, Kalin X, Stussi E. The effects of shoes on the torsion and rearfoot motion in running. Med Sci Sports Exerc. 1991;23(4):482–90.
Bishop C, Paul G, Thewlis D. The reliability, accuracy and minimal detectable difference of a multi-segment kinematic model of the foot shoe complex. Gait Posture. 2013;37(4):552–57.
Felson DT, Redmond AC, Chapman GJ, Smith TO, Hamilton DF, Jones RK, et al. Recommendations for the conduct of efficacy trials of treatment devices for osteoarthritis: a report from a working group of the Arthritis Research UK Osteoarthritis and Crystal Diseases Clinical Studies Group. Rheumatology (Oxford). 2016;55(2):320–26.
van Hoeve S, de Vos J, Weijers P, Verbruggen J, Willems P, Poeze M, et al. Repeatability of the oxford foot model for kinematic gait analysis of the foot and ankle. Clin Res Foot Ankle. 2015;3:171.
Milner CE, Brindle RA. Reliability and minimal detectable difference in multisegment foot kinematics during shod walking and running. Gait Posture. 2016;43:192–97.
Ferber R, Davis IM, Williams 3rd DS. Effect of foot orthotics on rearfoot and tibia joint coupling patterns and variability. J Biomech. 2005;38(3):477–83.
Davis IS, Zifchock RA, DeLeo AT. A comparison of rearfoot motion control and comfort between custom and semicustom foot orthotic devices. J Am Podiatr Med Assoc. 2008;98(5):394–403.
Cobb SC, Tis LL, Johnson JT. Custom-molded foot-orthosis intervention and multisegment medial foot kinematics during walking. J Athl Train. 2011;46(4):358–65.
Okita N, Meyers SA, Challis JH, Sharkey NA. An objective evaluation of a segmented foot model. Gait Posture. 2009;30(1):27–34.
Nester C, Liu A, Ward E, Howard D, Cocheba J, Derrick T. Error in the description of foot kinematics due to violation of rigid body assumptions. J Biomech. 2010;43(4):666–72.
Demura T, Demura S-I, Yamaji S, Yamada T, Kitabayashi T. Gait characteristics when walking with rounded soft sole shoes. Foot. 2012;22(1):18–23.
Najafi B, Miller D, Jarrett BD, Wrobel JS. Does footwear type impact the number of steps required to reach gait steady state?: an innovative look at the impact of foot orthoses on gait initiation. Gait Posture. 2010;32:29–33.
McCormick CJ, Bonanno DR, Landorf KB. The effect of customised and sham foot orthoses on plantar pressures. J Foot Ankle Res. 2013;6(1):19.
Deschamps K, Staes F, Bruyninckx H, Busschots E, Jaspers E, Atre A, et al. Repeatability in the assessment of multi-segment foot kinematics. Gait Posture. 2012;35(2):255–60.