Recently, pattern recognition methods have been deployed in the classification of multiple activation states from mechanomyogram (MMG) signals for the purpose of controlling switching interfaces. Given the propagative properties of MMG signals, it has been suggested that MMG classification should be robust to changes in sensor placement. Nonetheless, this purported robustness remains speculative to date. This study sought to quantify the change in classification accuracy, if any, when a classifier trained with MMG signals from the muscle belly, is subsequently tested with MMG signals from a nearby location. An arrangement of 5 accelerometers was attached to the flexor carpi radialis muscle of 12 able-bodied participants; a reference accelerometer was located over the muscle belly, two peripheral accelerometers were positioned along the muscle's transverse axis and two more were aligned to the muscle's longitudinal axis. Participants performed three classes of muscle activity: wrist flexion, wrist extension and semi-pronation. A collection of time, frequency and time-frequency features were considered and reduced by genetic feature selection. The classifier, trained using features from the reference accelerometer, was tested with signals from the longitudinally and transversally displaced accelerometers. Classification degradation due to accelerometer displacement was significant for all participants, and showed no consistent trend with the direction of displacement. Further, the displaced accelerometer signals showed task-dependent de-correlations with respect to the reference accelerometer. These results indicate that MMG signal features vary with spatial location and that accelerometer displacements of only 1-2 cm cause sufficient feature drift to significantly diminish classification accuracy. This finding emphasizes the importance of consistent sensor placement between MMG classifier training and deployment for accurate control of switching interfaces.
Tài liệu tham khảo
Barry DT, Cole NM: Muscle sounds are emitted at the resonant frequencies of skeletal muscle. IEEE transactions on biomedical engineering 1990, 37(5):525–531. 10.1109/10.55644
Orizio C: Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies. Critical reviews in biomedical engineering 1993, 21(3):201–243.
Orizio C, Perini R, Diemont B, Maranzana Figini M, Veicsteinas A: Spectral analysis of muscular sound during isometric contraction of biceps brachii. Journal of applied physiology 1990, 68(2):508–512.
Orizio C, Liberati D, Locatelli C, De Grandis D, Veicsteinas A: Surface mechanomyogram reflects muscle fibres twitches summation. Journal of biomechanics 1996, 29(4):475–481. 10.1016/0021-9290(95)00063-1
Petitjean M, Maton B: Phonomyogram from single motor units during voluntary isometric contraction. European journal of applied physiology 1995, 71(2):215. 10.1007/BF00854981
Akataki K, Mita K, Watakabe M: Electromyographic and mechanomyographic estimation of motor unit activation strategy in voluntary force production. Electromyography and clinical neurophysiology 2004, 44(8):489–496.
Shinohara M, Sogaard K: Mechanomyography for studying force fluctuations and muscle fatigue. Exercise and sport sciences reviews 2006, 34(2):59–64. 10.1249/00003677-200604000-00004
Beck TW, Housh TJ, Johnson GO, Cramer JT, Weir JP, Coburn JW, Malek MH: Does the frequency content of the surface mechanomyographic signal reflect motor unit firing rates? A brief review. Journal of electromyography and kinesiology 2007, 17(1):1–13. 10.1016/j.jelekin.2005.12.002
Alves N, Chau T: Stationarity distributions of mechanomyogram signals from isometric contractions of extrinsic hand muscles during functional grasping. Journal of electromyography and kinesiology 2008, 18(3):509–515. 10.1016/j.jelekin.2006.11.010
Barry DT: Muscle sounds from evoked twitches in the hand. Archives of physical medicine and rehabilitation 1991, 72(8):573–575.
Watakabe M, Itoh Y, Mita K, Akataki K: Technical aspects of mechanomyography recording with piezoelectric contact sensor. Medical and biological engineering and computing 1998, 36(5):557–561. 10.1007/BF02524423
Barry DT: Vibrations and sounds from evoked muscle twitches. Electromyography and clinical neurophysiology 1992, 32(1–2):35–40.
Orizio C, Baratta RV, Zhou BH, Solomonow M, Veicsteinas A: Force and surface mechanomyogram relationship in cat gastrocnemius. Journal of electromyography and kinesiology 1999, 9(2):131–140. 10.1016/S1050-6411(98)00044-3
Madeleine P, Arendt-Nielsen L: Experimental muscle pain increases mechanomyographic signal activity during sub-maximal isometric contractions. Journal of electromyography and kinesiology 2005, 15(1):27–36. 10.1016/j.jelekin.2004.06.006
Madeleine P, Jorgensen LV, Sogaard K, Arendt-Nielsen L, Sjogaard G: Development of muscle fatigue as assessed by electromyography and mechanomyography during continuous and intermittent low-force contractions: effects of the feedback mode. European journal of applied physiology 2002, 87(1):28–37. 10.1007/s00421-002-0578-4
Barry DT, Gordon KE, Hinton GG: Acoustic and surface EMG diagnosis of pediatric muscle disease. Muscle and nerve 1990, 13(4):286–290. 10.1002/mus.880130403
Xie HB, Zheng YP, Guo JY: Classification of the mechanomyogram signal using a wavelet packet transform and singular value decomposition for multifunction prosthesis control. Physiological measurement 2009, 30(5):441–457. 10.1088/0967-3334/30/5/002
Silva J, Heim W, Chau T: A self-contained, mechanomyography-driven externally powered prosthesis. Archives of physical medicine and rehabilitation 2005, 86(10):2066–2070. 10.1016/j.apmr.2005.03.034
Alves N, Chau T: The design and testing of a novel mechanomyogram-driven switch controlled by small eyebrow movements. Journal of NeuroEngineering and Rehabilitation 7(22):
Alves N, Chau T: Uncovering patterns of forearm muscle activity using multi-channel mechanomyography. Journal of electromyography and kinesiology, in press. (Eprint available online doi:10.1016/j.jelekin.2009.09.003).
Barry DT, Leonard JA Jr, Gitter AJ, Ball RD: Acoustic myography as a control signal for an externally powered prosthesis. Archives of physical medicine and rehabilitation 1986, 67(4):267–269.
Englehart K, Hudgins B: A robust, real-time control scheme for multifunction myoelectric control. IEEE transactions on biomedical engineering 2003, 50(7):848–854. 10.1109/TBME.2003.813539
Graupe D, Salahi J, Kohn KH: Multifunctional prosthesis and orthosis control via microcomputer identification of temporal pattern differences in single-site myoelectric signals. Journal of Biomedical Engineering 1982, 4(1):17. 10.1016/0141-5425(82)90021-8
Cescon C, Madeleine P, Farina D: Longitudinal and transverse propagation of surface mechanomyographic waves generated by single motor unit activity. Medical and biological engineering and computing 2008, 6(9):871–877. 10.1007/s11517-008-0357-4
Farina D, Li X, Madeleine P: Motor unit acceleration maps and interference mechanomyographic distribution. Journal of Biomechanics 2008, 41(13):2843–2849. 10.1016/j.jbiomech.2008.07.007
Cescon C, Madeleine P, Graven-Nielsen T, Merletti R, Farina D: Two-dimensional spatial distribution of surface mechanomyographical response to single motor unit activity. Journal of neuroscience methods 2007, 159(1):19–25. 10.1016/j.jneumeth.2006.06.011
Madeleine P, Tuker K, Arendt-Nielsen L, Farina D: Heterogeneous mechanomyographic absolute activation of paraspinal muscles assessed by a two-dimensional array during short and sustained contractions. Journal of Biomechanics 2007, 40(12):2663–2671. 10.1016/j.jbiomech.2006.12.011
Ouamer M, Boiteux M, Petitjean M, Travens L, Sales A: Acoustic myography during voluntary isometric contraction reveals non-propagative lateral vibration. Journal of Biomechanics 1999, 32(12):1279–1285. 10.1016/S0021-9290(99)00132-3
Cescon C, Farina D, Gobbo M, Merletti R, Orizio C: Effect of accelerometer location on mechanomyogram variables during voluntary, constant-force contractions in three human muscles. Medical & biological engineering & computing 2004, 42(1):121–127. 10.1007/BF02351021
Madeleine P, Cescon C, Farina D: Spatial and force dependency of mechanomyographic signal features. Journal of neuroscience methods 2006, 158(1):89–99. 10.1016/j.jneumeth.2006.05.018
Cescon C, Gazzoni M, Gobbo M, Orizio C, Farina D: Non-invasive assessment of single motor unit mechanomyographic response and twitch force by spike-triggered averaging. Medical and biological engineering and computing 2004, 42(4):496–501. 10.1007/BF02350990
Moore KL, Dalley AF, Agur AMR: Clinically oriented anatomy. 6th edition. Lippincott Williams & Wilkins; 2006.
Madeleine P, Bajaj P, Sogaard K, Arendt-Nielsen L: Mechanomyography and electromyography force relationships during concentric, isometric and eccentric contractions. Journal of electromyography and kinesiology 2001, 11(2):113–121. 10.1016/S1050-6411(00)00044-4
Lee J, Steele C, Chau T: Dual-axis swallowing accelerometry signals. Physiological measurement 2008, 29: 1105–1120. 10.1088/0967-3334/29/9/008
Boostani R, Moradi MH: Evaluation of the forearm EMG signal features for the control of a prosthetic hand. Physiological measurement 2003, 24(2):309–319. 10.1088/0967-3334/24/2/307
Lee J, Sejdic E, Steele CM, Chau T: Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population. BioMedical Engineering OnLine 2010, 9(1):7. 10.1186/1475-925X-9-7
Atal BS: Effectiveness of linear prediction characteristics of the speech wave for automatic speaker identification and verification. The Journal of the Acoustical Society of America 1974, 55(6):1304–1322. 10.1121/1.1914702
Momen K, Krishnan S, Chau T: Real-time classification of forearm electromyographic signals corresponding to user-selected intentional movements for multifunction prosthesis control. IEEE Transactions on Neural Systems and Rehabilitation Engineering 2007, 15(4):535–542. 10.1109/TNSRE.2007.908376
Zecca M, Micera S, Carrozza MC, Dario P: Control of multifunctional prosthetic hands by processing the electromyographic signal. Critical Reviews in Biomedical Engineering 2002, 30(4–6):459–485. 10.1615/CritRevBiomedEng.v30.i456.80
Duda RO: Pattern classification. 2nd edition. New York: Wiley; 2001.
Loog M, Duin RPW, Haeb-Umbach R: Multiclass linear dimension reduction by weighted pairwise Fisher criteria. IEEE Transactions on Pattern Analysis and Machine Intelligence 2001, 23(7):762–766. 10.1109/34.935849
Hargrove LJ, Englehart K, Hudgins B: A comparison of surface and intramuscular myoelectric signal classification. IEEE transactions on bio-medical engineering 2007, 54(5):847–853. 10.1109/TBME.2006.889192
Hargrove L: A training strategy to reduce classification degradation due to electrode displacements in pattern recognition based myoelectric control. Biomedical signal processing and control 2008, 3(2):175. 10.1016/j.bspc.2007.11.005
Hargrove L, Englehart K, Hudgins B: The effect of electrode displacements on pattern recognition based myoelectric control. Conference proceedings IEEE Engineering in Medicine and Biology Society 2006, 1: 2203–2206. full_text
Filligoi GC, Felici F: Detection of hidden rhythms in surface EMG signals with a non-linear time-series tool. Medical engineering & physics 1999, 21(6–7):439–448. 10.1016/S1350-4533(99)00073-9
Dauwels J, Vialatte F, Musha T, Cichocki A: A comparative study of synchrony measures for the early diagnosis of Alzheimer's disease based on EEG. NeuroImage 2009, 49(1):668–693. 10.1016/j.neuroimage.2009.06.056
Xie HB, Guo JY, Zheng YP: Uncovering chaotic structure in mechanomyography signals of fatigue biceps brachii muscle. Journal of Biomechanics 2009, 43(6):1224–1226. 10.1016/j.jbiomech.2009.11.035
Xie HB, Guo JY, Zheng YP: A comparative study of pattern synchronization detection between neural signals using different cross-entropy measures. Biological cybernetics 2010, 102(2):123–135. 10.1007/s00422-009-0354-1
Petitjean M, Maton B, Fourment A: Summation of elementary phonomyograms during isometric twitches in humans. European journal of applied physiology and occupational physiology 1998, 77(6):527. 10.1007/s004210050371
Watakabe M, Mita K, Akataki K, Itoh Y: Mechanical behaviour of condenser microphone in mechanomyography. Medical and biological engineering and computing 2001, 39(2):195–201. 10.1007/BF02344804
Orizio C: Surface Mechanomyogram. In Electromyography: Physiology, Engineering and Noninvasive Applications. Edited by: Merletti R, Parker P. New Jersey: John Wiley & Sons; 2004:305–319. full_text