Ten-year follow-up of a proximal circumferential porous-coated femoral prosthesis: radiographic evaluation and stability

Journal of Orthopaedic Science - Tập 7 - Trang 68-73 - 2002
Yoshio Takatori1, Ichiro Nagai1, Toru Moro1, Yoshihiro Kuruta1, Tatsuro Karita1, Akihiko Mabuchi1, Setsuo Ninomiya2
1Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 3-28-6 Mejirodai, Bunkyo-ku, Tokyo 112-8688, Japan
2Department of Orthopaedic Surgery, Saitama Medical School, Moroyama, Iruma, Saitama 350-0495, Japan

Tài liệu tham khảo

Charnley, 1972, Long term results of low friction arthroplasty of the hip performed as a primary intervention, J Bone Joint Surg Br, 54, 61, 10.1302/0301-620X.54B1.61 Dahl, 1997, Cardiorespiratory and vascular dysfunction related to major reconstructive orthopedic surgery, Acta Orthop Scand, 68, 607, 10.3109/17453679708999038 Duncan, 1995, Fractures of the femur after hip replacement, Instructional course lectures, 44, 293 Emerson, 1999, Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty, J Bone Joint Surg Am, 81, 1291, 10.2106/00004623-199909000-00010 Engh, 1990, Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components, Clin Orthop, 257, 107, 10.1097/00003086-199008000-00022 Gruen, 1979, "Modes of failure" of cemented stem-type femoral components. A radiographic analysis of loosening, Clin Orthop, 141, 17 Huiskes, 1990, The various stress patterns of press-fit, ingrown, and cemented femoral stems, Clin Orthop, 261, 27, 10.1097/00003086-199012000-00006 Kim, 1992, Results of the Harris-Galante cementless hip prosthesis, J Bone Joint Surg Br, 74, 83, 10.1302/0301-620X.74B1.1732272 Mallory, 1998, The Mallory/Head system, 195 Mulliken, 1996, A tapered tita-nium femoral stem inserted without cement in a total hip arthroplasty. Radiographic evaluation and stability, J Bone Joint Surg Am, 78, 1214, 10.2106/00004623-199608000-00012 Okabe, 1998, Over 5 years follow-up results of total hip without cement arthroplasty. Study of femoral component, J East Jpn Orthop Traumatol, 10, 388 Puolakka, 1999, Poor survival of cementless Biomet total hip. A report on 1047 hips from the Finnish arthroplasty register, Acta Orthop Scand, 70, 425, 10.3109/17453679909000975 Robertson, 1996, Results of the Bi-Metric cementless hip arthroplasty, Orthopedics, 19, 673, 10.3928/0147-7447-19960801-11 Rorabeck, 1996, Comparative results of cemented and cementless total hip arthroplasty, Clin Orthop, 325, 330, 10.1097/00003086-199604000-00044 Schwartz, 1989, Femoral fracture during noncemented total hip arthroplasty, J Bone Joint Surg Am, 71, 1135, 10.2106/00004623-198971080-00003 Singh, 1970, Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis, J Bone Joint Surg Am, 52, 457, 10.2106/00004623-197052030-00005 Søballe, 1993, Migration of hydroxyapatite coated femoral prostheses. A roentgen stereophotogrammetric study, J Bone Joint Surg Br, 75, 681, 10.1302/0301-620X.75B5.8397213 Sutherland, 1982, A ten-year followup of one hundred consecutive Muller curved-stem total hipreplacement arthroplasties, J Bone Joint Surg Am, 64, 970, 10.2106/00004623-198264070-00002 Tsutsui, 1999, Exposure of macro-phage-like cells to titanium particles does not affect bone resorption, but inhibits bone formation, J Orthop Sci, 4, 32, 10.1007/s007760050071 Wang, 1997, Prosthetic metals interfere with the functions of human osteoblastic cells in vitro, Clin Orthop, 339, 216, 10.1097/00003086-199706000-00030