Tactile sensor based on piezoelectric resonance

SENSORS, 2002 IEEE - Tập 2 - Trang 1643-1647 vol.2
G.M. Krishna1, K. Rajanna1
1Department of Instrumentation, Indian Institute of Science, Bangalore, India

Tóm tắt

We discuss the realization of tactile sensor based on the principle of change in piezoelectric resonance frequency with applied pressure. An array of electrodes has been adopted on either side of the PZT material to achieve independent resonators. The common areas sandwiched between the electrodes and excitable at the resonance frequency of the PZT material are used to form the sensitive area of the tactile sensor. The electrodes were deposited using a sputtering technique. Tactile sensors with 3/spl times/3, 7/spl times/7 and 15/spl times/15 array of electrodes are developed with different electrode dimensions and separation between the electrodes. The tactile sensor has been interfaced to a computer for the convenience of automatic scanning and making it more user interactive. The tactile sensors developed with different spatial resolution were tested for different shaped objects placed in contact with the sensor. The 3/spl times/3 matrix tactile sensor showed relatively poor spatial resolution whereas 15/spl times/15-matrix tactile sensor showed improved spatial resolution. The sensor with 7/spl times/7 matrix elements was tested for its sensitivity to different extents of applied force/pressure. The output response study carried out on the sensors indicated that these sensors can provide information not only about the extent of force/pressure applied on the object, but also the contour of the object which is in contact with the sensor.

Từ khóa

#Tactile sensors #Resonance #Electrodes #Spatial resolution #Resonant frequency #Sensor arrays #Testing #Force sensors #Sputtering #Computer interfaces

Tài liệu tham khảo

neumann, 1982, Medical Progress through technology, 9, 95 omata, 1992, New tactile sensor like human hand and its applications, Sensors and Actuators - A, 35, 9, 10.1016/0924-4247(92)87002-X 10.1108/eb004474 10.1016/S0924-4247(97)01686-5 rebman, 1982, A tactile sensor with Electro optic transduction, Proc 3rd Int Conf Robot Vision and Sensory Controls, 21, 0 10.1109/T-UFFC.1987.26932 10.1109/10.8695 sugiyama, 1990, Tactile image detection using 1 K - element silicon pressure sensor array, Sensors and Actuators, a21 a23, 397, 10.1016/0924-4247(89)80001-9 10.1109/4.841500 10.1016/S0924-4247(99)00359-3 jayawant, 1986, Robot Tactile sensing: A new array sensor, Robot Sensors Tactile and Non-Vision, 199 0 10.1016/0924-4247(93)80151-6 tanie, 1986, Advances in Tactile sensors for robotics, Proceedings of the 6th Sensor Symposium, 63 benes, 1995, Sensors based on piezoelectric resonators, Sensors and Actuators, a48, 1, 10.1016/0924-4247(95)00846-2 10.1109/58.16980 murali krishna, 2001, Development of tactile sensors based on piezoelectric resonance and surface acoustic wave techniques