Surface characterizations and corrosion resistance of nickel–titanium orthodontic archwires in artificial saliva of various degrees of acidity

Journal of Biomedical Materials Research - Part A - Tập 74A Số 4 - Trang 629-639 - 2005
Her‐Hsiung Huang1
1Department of Chemical and Materials Engineering, National University of Kaohsiung, No. 700, Kaohsiung University Road, Kaohsiung 811, Taiwan

Tóm tắt

Abstract

This study investigated the surface characterizations and corrosion resistance of as‐received commercial nickel–titanium (NiTi) dental orthodontic archwires from different manufacturers using a cyclic potentiodynamic test in artificial saliva with various acidities. An atomic force microscope was used to evaluate the surface topography of the NiTi wires. The surface chemical analysis of the passive film on the NiTi wires was characterized using X‐ray photoelectron spectroscopy and Auger electron spectroscopy. A scanning electron microscope, together with an energy‐dispersive spectrometer, was used to analyze the surface characterizations of the NiTi wires before and after the corrosion tests. Two‐way analysis of variance was used to analyze the corrosion‐resistance parameters with the factors of wire manufacturer and solution pH. The results showed that the surface structure of the passive film on the tested NiTi wires were identical, containing mainly TiO2, with small amounts of NiO. A different surface topography was observed on the NiTi wires from various manufacturers. The corrosion tests showed that both the wire manufacturer and solution pH had a statistically significant influence on the corrosion potential, corrosion rate, passive current, breakdown potential, and crevice‐corrosion susceptibility. The difference in the corrosion resistance among these NiTi dental orthodontic archwires did not correspond with the surface roughness and pre‐existing defects. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005

Từ khóa


Tài liệu tham khảo

Moorleghem WV, 1998, Shape memory and superelastic alloys: The new medical materials with growing demand, Biomed Mater Eng, 8, 55

Torrisi L, 1999, The NiTi superelastic alloy application to the dentistry field, Biomed Mater Eng, 9, 39

Brantley WA, 2001, Orthodontic Materials: Scientific and Clinical Aspects, 77

10.1002/(SICI)1097-4636(200007)51:1<47::AID-JBM7>3.0.CO;2-P

10.1002/1097-4636(20000915)51:4<685::AID-JBM17>3.0.CO;2-S

10.1179/095066001771048745

10.1016/S0142-9612(03)00188-1

10.1016/S0140-6736(00)03262-1

10.1002/(SICI)1097-4636(19970615)35:4<451::AID-JBM5>3.0.CO;2-G

10.1097/00006534-199203000-00025

10.1016/S0142-9612(97)00210-X

10.1002/jbm.a.10463

Shin JS, 2003, In vitro surface corrosion of stainless steel and NiTi orthodontic appliances, Aust Orthod J, 19, 13

Kim H, 1999, Corrosion of stainless steel, nickel‐titanium, coated nickel‐titanium, and titanium orthodontic wires, Angle Orthod, 69, 39

Hunt NP, 1999, An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires, Angle Orthod, 69, 433

10.1016/S0257-8972(01)01356-1

10.1016/S0142-9612(03)00271-0

10.1016/S0169-4332(02)01414-9

10.1016/S0921-5093(03)00629-4

Hua YJ, 2003, Effect of surface oxidation and nitrogen ion implantation on corrosion resistance of equiatomic NiTi shape memory alloy, J Funct Mater, 34, 654

10.1002/jbm.10114

10.1016/S0167-577X(02)00809-1

10.2351/1.1514236

10.1023/A:1013831011241

10.1016/j.scriptamat.2003.09.028

10.1016/j.biomaterials.2003.11.042

10.1016/S0142-9612(01)00328-3

Geis‐Gerstorfer J, 1985, Effect of potassium thiocyanate on corrosion behavior of non‐precious metal dental alloys, Dtsch Zahnärztl Z, 40, 87

Jones DA, 1996, Principles and prevention of corrosion, 75

10.1111/j.1365-2842.1985.tb01293.x

10.5006/0010-9312-28.8.283

ASTM G61–86 (Reapproved 2003).Standard test method for conducting cyclic potentiodynamic polarization measurements for localized corrosion susceptibility of iron‐ nickel‐ or cobalt‐based alloys.American Society for Testing and Materials (ASTM) Philadelphia:2003.

10.1016/S1389-0344(02)00041-2

10.1016/S0142-9612(97)00210-X

10.1116/1.579461

10.3323/jcorr1991.40.834

10.1016/0142-9612(89)90134-8

Huang HH, 2005, Variation in corrosion resistance of NiTi wires from different manufacturers, Angle Orthod, 75, 569

10.1023/A:1008953412622

Abiko Y, 1996, Effects of NiTi surface texture on corrosion resistance and cellular response, J Jpn Soc Dent Products, 9, 9

10.1016/0002-9416(82)90545-0

Oshida Y, 1992, Microanalytical characterization and surface modification of TiNi orthodontic archwires, Biomed Mater Eng, 2, 51