Study on Prefire Phenomena of Wire Insulation at Microgravity

Springer Science and Business Media LLC - Tập 20 - Trang 107-113 - 2008
Wenjun Kong1, Baorui Wang1, Weikuo Zhang1, Yuhua Ai1, Shiqi Lao1
1Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing, China

Tóm tắt

The experimental hardware was developed to perform the experiments of prefire characteristics of wire insulation caused by overload on board the SJ-8 China recoverable satellite. In the experiments, the prefire characteristics including the temperature and radiation characteristics of the wire insulations were presented. The temperature histories of the wire insulation in microgravity and the low-pressure environment in normal gravity were obtained. Effects of overloaded currents on the fire initiation were investigated for different wire coiled states. The results indicate that the natural convection almost vanished and the heat loss of the electric components decreased in the microgravity environment. It might cause overheating of the electric components and then results in fire, and thus the fire risks of wire in the microgravity condition are much more dangerous than that in normal gravity under the condition of overload.

Tài liệu tham khảo

Gebhart, B., Jaluria, Y., Mahajan, R.L., Sammakia, B.: Buoyancy-induced flows and transport. Hemisphere, Washington, D.C. (1988)

Greenberg, P.S., Sacksteder, K.R., Kashiwagi, T.: Wire insulation flammability. NASA CP 10174, p.25 (1995)

Kikuchi, M., Fujita, O., Ito, K., Sato, A., Sakuraya, T.: Flame spread over polymeric wire insulation in microgravity. Space Forum 6, 245 (2000)