Statistical flattening of MEG beamformer images

Human Brain Mapping - Tập 18 Số 1 - Trang 1-12 - 2003
Gareth R. Barnes1, Arjan Hillebrand
1The Wellcome Trust Laboratory for MEG Studies, Neurosciences Research Institute, Aston University, Birmingham B4 7ET, United Kingdom. [email protected]

Tóm tắt

AbstractWe propose a method of correction for multiple comparisons in MEG beamformer based Statistical Parametric Maps (SPMs). We introduce a modification to the minimum‐variance beamformer, in which beamformer weights and SPMs of source‐power change are computed in distinct steps. This approach allows the calculation of image smoothness based on the computed weights alone. In the first instance we estimate image smoothness by looking at local spatial correlations in residual images generated using random data; we then go on to show how the smoothness of the SPM can be obtained analytically by measuring the correlations between the adjacent weight vectors. In simulations we show that the smoothness of the SPM is highly inhomogeneous and depends on the source strength. We show that, for the minimum variance beamformer, knowledge of image smoothness is sufficient to allow for correction of the multiple comparison problem. Per‐voxel threshold estimates, based on the voxels extent (or cluster size) in flattened space, provide accurate corrected false positive error rates for these highly inhomogeneously smooth images. Hum. Brain Mapping 18:1–12, 2003. © 2002 Wiley‐Liss, Inc.

Từ khóa


Tài liệu tham khảo

10.1002/1097-0193(200102)12:2<79::AID-HBM1005>3.0.CO;2-I

10.1016/S1053-8119(01)91414-4

10.1109/PROC.1969.7278

2000 Helsinki Univ. of Technology Espoo Finland D Cheyne GR Barnes IE Holliday PL Furlong J Neonen T Ilmoniemi T Katila Localization of brain activity associated with non‐time‐locked tactile stimulation using synthetic aperture magnetometry (SAM) 255 258

10.1006/nimg.1996.0074

10.1002/hbm.460020402

10.1006/nimg.1996.0018

10.1109/10.664200

10.1073/pnas.98.2.694

10.1097/00001756-200107030-00025

10.1016/S0168-5597(97)00091-9

10.1006/nimg.1999.0508

10.1109/10.725331

10.1109/10.141192

10.1016/S1388-2457(99)00141-8

10.1016/S0167-8760(96)00066-9

10.1097/00004728-199509000-00017

Robinson SE, 1992, Biomagnetism: clinical aspects, 761

Robinson SE, 1999, Recent advances in biomagnetism, 302

10.1109/42.750262

10.1016/S1053-8119(01)91590-3

10.1006/nimg.2001.1050

10.1109/10.237672

10.1006/nimg.2000.0611

10.1109/10.623056

Vrba j, 1999, Recent advances in biomagnetism

2001 Helsinki Univ. of Technology Espoo Finland J Vrba SE Robinson J Neonen T Ilmoniemi T Katila Differences between synthetic aperture magnetometry (SAM) and linear beamformers 681 684

10.1002/(SICI)1097-0193(1996)4:1<58::AID-HBM4>3.0.CO;2-O

10.1002/(SICI)1097-0193(1999)8:2/3<98::AID-HBM5>3.0.CO;2-F