This paper presents the design and preliminary results for a flow-through particle separation unit using standing ultrasonic waves. The results indicate that good separation is obtained at residence times as low as 14 seconds and liquid velocities of 2 mm/sec. The effects of thermally and acoustically induced streaming are discussed. The unit is being used to assess the effective ranges and limits for key parameters in the design of larger scale units.

Từ khóa

#Particle separators #Chemical technology #Pharmaceutical technology #Filtration #Laboratories #Chemical industry #Frequency #Glass #Bonding #Petroleum industry

Tài liệu tham khảo

groschl, 1998, Ultrasonic Separation of Suspended Particles - Part II: Design and Operation of Separation Devices, Acustica, 84, 632 10.1016/S0043-1354(97)00088-2 grosch, 1998, Ultrasonic Separation of Suspended Particles - Part I: Fundamentals, Acustica, 84, 432 10.1016/S0925-4005(99)00495-5 groschl, 1998, Ultrasonic Separation of Suspended Particles - Part III: Application in Biotechnology, Acustica, 84, 815 10.1016/0009-2509(95)00154-W 10.1063/1.119395 yosioka, 1955, Acoustic radiation pressure on a compressible sphere, Acustica 5, 167 10.1016/S0041-624X(99)00151-1 10.1098/rspa.1934.0215 weiser, 1984, Interparticle Forces on Red Cells in a Standing Wave Field, Acustica, 56, 114