Standard‐free kinetic calibration for rapid on‐site analysis by solid‐phase microextraction

Journal of Separation Science - Tập 31 Số 6-7 - Trang 1167-1172 - 2008
Gangfeng Ouyang1, Jibao Cai2,3, Xu Zhang3, Hui Li3, Janusz Pawliszyn
1School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou, China
2Department of Chemistry, University of Science and Technology of China, Heifei, China
3Department of Chemistry, University of Waterloo, Ontario, Canada

Tóm tắt

AbstractIn this study, a new calibration method, standard‐free kinetic calibration, is proposed for rapid on‐site analysis by solid‐phase microextraction (SPME), based on the diffusion‐controlled mass transfer model and equilibrium extraction. With this calibration method, all analytes can be directly calibrated with only two samplings. The feasibility of this calibration method was validated in a standard aqueous solution flow‐through system and a standard gas flow‐through system. The distribution coefficients of five polycyclic aromatic hydrocarbons (PAHs), including naphthalene, acenaphthene, fluorene, anthracene, and pyrene, between water and the PDMS fiber coating were determined and the concentrations of the PAHs in the flow‐through system were successfully calibrated with the proposed standard‐free calibration method. The extracted amounts of BTEX (benzene, toluene, ethylbezene, o‐xylene) at equilibrium were also successfully calibrated with this method with two rapid sampling periods at 5 and 10 s. Compared with the previous calibration methods for rapid on‐site analysis by SPME, this method does not require a standard to calibrate the extraction, nor does it require additional equipment to control or measure the flow velocity of the sample matrix. In addition, all of the extracted analytes can be quantified without considering whether the system reached equilibrium. The newly proposed standard‐free kinetic calibration approach enriched the calibration methods available for on‐site analysis by SPME.

Từ khóa


Tài liệu tham khảo

10.1021/ac00218a019

Pawliszyn J. Solid Phase Microextraction – Theory and Practice Wiley‐VCH New York 1997.

Pawliszyn J. (Ed.) Applications of Solid Phase Microextraction RSC Cornwall UK 1999.

10.1007/s00216-006-0460-z

10.1007/s00216-004-2587-0

10.1016/S0045-6535(02)00845-7

10.1016/S0021-9673(03)00328-5

10.1016/j.trac.2006.05.005

10.1021/es0260770

10.1021/es035318g

10.1021/es049680m

10.1039/b410597d

10.1021/ac981028k

10.1016/S0021-9673(00)00295-8

10.1021/ac000518l

10.1021/ac000903a

10.1021/ac0349328

10.1021/ac026315

10.1021/ac0490806

10.1021/ac051035q

10.1021/ac000629k

10.1039/b300968h

10.1007/s00216-003-2489-6

10.1021/ac0495081

10.1039/b406310d

10.1016/j.chroma.2004.12.084

10.1021/ac9609541

10.1021/ac970024x

10.1021/ac060669

10.1021/ac051493z

10.1016/j.chroma.2006.05.062

10.1093/chromsci/44.6.317

10.1021/es062647a

10.1373/clinchem.2005.064758

10.1016/j.chroma.2005.08.072

10.1016/j.chroma.2003.10.079

10.1021/ac991395b

10.1021/ac061626w