Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?
Tóm tắt
The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm2/m2 < indexed effective orifice area ≤ 0.85 cm2/m2) on midterm outcomes after isolated aortic valve replacement with a 17-mm St. Jude Medical Regent valve in a large series of patients, and to determine if these effects are influenced by patient confounding variables. One-hundred and six patients with and without moderate prosthesis-patient mismatch early after implantation of a 17-mm Regent valve at aortic position were included. Both clinical and echocardiographic assessments were performed preoperatively, at discharge and during follow-up period (mean follow-up time 52.6 ± 11.9 months). The prevalence of moderate prosthesis-patient mismatch was documented in 46 patients (43.4%) at discharge. During the follow-up period, no difference in the regression of left ventricular mass, decrease of transvalvular pressure gradients, mortality and prosthesis-related complications was observed between patients with and without moderate prosthesis-patient mismatch. After adjustment for several risk factors, moderate prosthesis-patient mismatch was associated with increased midterm mortality in patients with baseline left ventricular ejection fraction < 50% (HR: 1.80, p = 0.02), but with normal prognosis in those with preserved LV function. Younger age (cut off value = 65 years) was not an independent predictor of increased midterm mortality and valve-related complications in patients with moderate prosthesis-patient mismatch. Moderate prosthesis-patient mismatch after aortic valve replacement with a small mechanical prosthesis is associated with increased mortality and adverse events in patients with pre-existing left ventricular dysfunction. Selected patients with small aortic annulus can experience satisfactory clinical improvements and midterm survival after aortic valve replacement with a 17-mm Regent valve.
Tài liệu tham khảo
Mizoguchi H, Sakaki M, Inoue K, Iwata T, Tei K, Miura T: Mid-term results of small-sized St. Jude Medical Regent prosthetic valves (21 mm or less) for small aortic annulus. Heart Vessels. doi:10.1007/s00380-012-0306-x
Okamura H, Yamaguchi A, Nagano H, Itoh S, Morita H, Naito K, Yuri K, Adachi H: Mid-term outcomes after aortic valve replacement with the 17-mm St. Jude Medical Regent valve. Circ J. 2012, 76: 365-371. 10.1253/circj.CJ-11-0733.
Coutinho GF, Correia PM, Paupério G, De Oliveira F, Antunes MJ: Aortic root enlargement does not increase the surgical risk and short-term patient outcome?. Eur J Cardiothorac Surg. 2011, 40: 441-447.
Kulik A, Al-Saigh M, Chan V, Masters RG, Bédard P, Lam BK, Rubens FD, Hendry PJ, Mesana TG, Ruel M: Enlargement of the small aortic root during aortic valve replacement: is there a benefit?. Ann Thorac Surg. 2008, 85: 94-100. 10.1016/j.athoracsur.2007.07.058.
Bleiziffer S, Ali A, Hettich IM, Akdere D, Laubender RP, Ruzicka D, Boehm J, Lange R, Eichinger W: Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement. Heart. 2010, 96: 865-871. 10.1136/hrt.2009.177220.
Head SJ, Mokhles MM, Osnabrugge RL, Pibarot P, Mack MJ, Takkenberg JJ, Bogers AJ, Kappetein AP: The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years. Eur Heart J. 2012, 33: 1518-1529. 10.1093/eurheartj/ehs003.
Hong S, Yi G, Youn YN, Lee S, Yoo KJ, Chang BC: Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: a prospective observational study. J Thorac Cardiovasc Surg. doi:10.1016/j.jtcvs.2012.07.101
Daneshvar SA, Rahimtoola SH: Valve prosthesis-patient mismatch (VP-PM): a long-term perspective. J Am Coll Cardiol. 2012, 60: 1123-1135. 10.1016/j.jacc.2012.05.035.
Takaseya T, Kawara T, Tokunaga S, Kohno M, Oishi Y, Morita S: Aortic valve replacement with 17-mm St. Jude Medical prostheses for a small aortic root in elderly patients. Ann Thorac Surg. 2007, 83: 2050-2053. 10.1016/j.athoracsur.2007.01.044.
Okamura H, Yamaguchi A, Tanaka M, Naito K, Kimura N, Kimura C, Kobinata T, Ino T, Adachi H: The 17-mm St. Jude Medical Regent valve is a valid option for patients with a small aortic annulus. Ann Thorac Surg. 2009, 87: 90-94. 10.1016/j.athoracsur.2008.09.051.
Okamura H, Yamaguchi A, Noguchi K, Naito K, Yuri K, Adachi H: Hemodynamics and outcomes of aortic valve replacement with a 17- or 19-mm valve. Asian Cardiovasc Thorac Ann. 2010, 18: 450-455. 10.1177/0218492310381174.
Mohty D, Dumesnil JG, Echahidi N, Mathieu P, Dagenais F, Voisine P, Pibarot P: Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity, and left ventricular dysfunction. J Am Coll Cardiol. 2009, 53: 39-47. 10.1016/j.jacc.2008.09.022.
Jamieson WR, Ye J, Higgins J, Cheung A, Fradet GJ, Skarsgard P, Germann E, Chan F, Lichtenstein SV: Effect of prosthesis-patient mismatch on long-term survival with aortic valve replacement: assessment to 15 years. Ann Thorac Surg. 2010, 89: 51-58. 10.1016/j.athoracsur.2009.08.070.
Mannacio V, Di Tommaso L, Stassano P, De Amicis V, Vosa C: Myocardial metabolism and diastolic function after aortic valve replacement for aortic stenosis: influence of patient-prosthesis mismatch. Eur J Cardiothorac Surg. 2012, 41: 316-321. 10.1016/j.ejcts.2011.05.039.
Mohty D, Malouf JF, Girard SE, Schaff HV, Grill DE, Enriquez-Sarano ME, Miller FA: Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude Medical mechanical prostheses in the aortic position. Circulation. 2006, 113: 420-426. 10.1161/CIRCULATIONAHA.105.546754.
Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ: Chamber Quantification Writing Group; American Society of Echocardiography’s Guidelines and Standards Committee; European Association of Echocardiography. Recommendations for chamber quantification: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr. 2005, 18: 1440-1463. 10.1016/j.echo.2005.10.005.
Akins CW, Miller DC, Turina MI, Kouchoukos NT, Blackstone EH, Grunkemeier GL, Takkenberg JJ, David TE, Butchart EG, Adams DH, Shahian DM, Hagl S, Mayer JE, Lytle BW: STS; AATS; EACTS. Guidelines for reporting mortality and morbidity after cardiac valve interventions. Ann Thorac Surg. 2008, 85: 1490-1495. 10.1016/j.athoracsur.2007.12.082.
Minardi G, Manzara C, Creazzo V, Maselli D, Casali G, Pulignano G, Musumeci F: Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography. J Cardiothorac Surg. 2006, 1: 27-10.1186/1749-8090-1-27.
Amarelli C, Della Corte A, Romano G, Iasevoli G, Dialetto G, De Santo LS, De Feo M, Torella M, Scardone M, Cotrufo M: Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis. J Thorac Cardiovasc Surg. 2005, 129: 512-517. 10.1016/j.jtcvs.2004.07.007.
Garatti A, Mori F, Innocente F, Canziani A, Gagliardotto P, Mossuto E, Santoro T, Montericcio V, Frigiola A, Menicanti L: Aortic valve replacement with 17-mm mechanical prostheses: is patient-prosthesis mismatch a relevant phenomenon?. Ann Thorac Surg. 2011, 91: 71-77. 10.1016/j.athoracsur.2010.08.036.
Flameng W, Herregods MC, Vercalsteren M, Herijgers P, Bogaerts K, Meuris B: Prosthesis-patient mismatch predicts structural valve degeneration in bioprosthetic heart valves. Circulation. 2010, 121: 2123-2129. 10.1161/CIRCULATIONAHA.109.901272.
Brennan JM, Edwards FH, Zhao Y, O’Brien S, Booth ME, Dokholyan RS, Douglas PS, Peterson ED: DEcIDE AVR (Developing Evidence to Inform Decisions about Effectiveness–Aortic Valve Replacement) Research Team. Long-term safety and effectiveness of mechanical versus biologic aortic valve prostheses in older patients: results from the Society of Thoracic Surgeons Adult Cardiac Surgery National Database. Circulation. 2013, 127 (16): 1647-1655. 10.1161/CIRCULATIONAHA.113.002003.
Whitlock RP, Sun JC, Fremes SE, Rubens FD, Teoh KH: American College of Chest Physicians. Antithrombotic and thrombolytic therapy for valvular disease: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest. 2012, 141 (2 Suppl): e576S-600S.
Han QQ, Xu ZY, Zhang BR, Zou LJ, Hao JH, Huang SD: Primary triple valve surgery for advanced rheumatic heart disease in Mainland China: a single-center experience with 871 clinical cases. Eur J Cardiothorac Surg. 2007, 31: 845-850. 10.1016/j.ejcts.2007.02.005.
Fu B, Chen H, Dong L: Antithrombotic and thrombolytic therapy for valvular disease: can this guideline apply to Chinese?. Chest. 2013, 143 (5): 1513-1514. 10.1378/chest.12-3077.
Pibarot P, Dumesnil JG: Valve prosthesis-patient mismatch, 1978 to 2011: from original concept to compelling evidence. J Am Coll Cardiol. 2012, 60: 1136-1139. 10.1016/j.jacc.2012.07.005.