SRXRF experiments and analytical methods of mineral individual fluid inclusions

Elsevier BV - Tập 4 - Trang 63-67 - 2008
Chunxue Wu1, Yuying Huang2, Hongkui Li3, Chuanren Chen3, Wei He2, Kuifa Li3
1College of Computer Engineering, University of Shanghai for Science and Technology, Shanghai, China
2Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
3College of Geophysics & Oil Resource, Yangtze University, Jingzhou, China

Tóm tắt

This paper focuses on the micro-beam and trace element non-destructive experiment and analytical method of mineral fluid inclusions by synchrotron radiation X-ray fluorescence (SRXRF) microprobe at Beijing Synchrotron Radiation Facility (BSRF). The experimental instrument, measurement process and calculating method are introduced. A set of oil-and gas-containing typical mineral fluid inclusions taken from the Tazhong and Lunnan oilfields in the Tarim Basin were analyzed non-destructively. The trace element contents in the fluid inclusions may provide guidance for oil and gas exploration and development.

Tài liệu tham khảo

Chen C. R., Huang Y. Y., Li J. G., He W., Wei A. H., Wu Q. H., Wu C. X. and Li F. K. (2005) Study of the relationship between the trace element of oil-gas inclusion and oil-gas movement. High Energy Physics and Nuclear Physics, 29(Supp.), 51–55 (in Chinese) Huang Y. Y., Li K. F., He W., et al. (2001) Single fluid inclusion study by SRXRF microprobe. Nuclear Instruments and Methods in Physics Research A, 467–468, 1315–1317 Li K. F., Fang X. L., Liu C. Q., Niu Y. H., Zhang J. S. and Xiao Y. A. (1994) Detecting trace elements geological samples with synchrotron radiation X-ray fluorescence analysis. Journal of Jianghan Petroleum Institute, 16(1), 23–28 (in Chinese) Li K. F., Fang X. L., Niu Y. H., and Wu Y. R. (1995) The application of synchrotron radiation X-ray fluorescence analysis in petroleum exploration. Physics, 24(12), 755–758 (in Chinese) Mavrogenes J. A., Bodnar R. J., Anderson A. J., et al. (1995) Assessment of the uncertainties and limitations of quantitative elemental analysis of individual fluid inclusions using synchrotron radiation X-ray fluorescence (SXRF). Geochimica et Cosmochimica Acta, 59(19), 3987–3995 Philippot P., Menez B., Chevallier P., Gibert F., Legrand F., and Populus P. (1998) Absorption correction procedures for quantitative analysis of fluid inclusions using synchrotron radiation X-ray fluorescence. Chem. Geol., 144, 121–136 Vanko D. A., Sutton S. R., Rivers M. L., et al. (1993) Major-element ratios in synthetic fluid inclusions by synchrotron X-ray fluorescence microprobe. Chem. Geol., 109, 125–134 Wu, C. X., Huang Y. Y., Yang C., Li J., He W., Yu Z. W., Lin K. X. and Li K. F. (2002) Nondestructive analysis of individual fluid inclusion based on SRXRF and its application in oil geology. Nuclear Techniques, 125(10), 793–798 (in Chinese) Zhan X. C., Ma G. Z. An Q. X., Huang Y. Y., Wu Y. R. and Li G. C. (2002) Discussion on some problems related to fluid inclusion analysis by SXRF. Spectroscopy and Spectral Analysis, 20(3), 395–398 (in Chinese)