Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients

International Orthopaedics - Tập 34 Số 8 - Trang 1273-1276 - 2010
Kuang‐Kai Hsueh1, Chi-Kuang Fang2, Chuan‐Mu Chen2, Yu‐Ping Su2, Heng‐Fei Wu2, Fang‐Yao Chiu2
1Departments of Orthopaedics & Traumatology, Taipei Veterans General Hospital, National Yang-Ming University, Taiwan, Republic of China [corrected].
2Departments of Orthopaedics & Traumatology, Taipei Veterans General Hospital, National Yang-Ming University, Taipei, People’s Republic of China

Tóm tắt

Từ khóa


Tài liệu tham khảo

American Society of Anesthesiologists (2009) New classification of physical status. Anesthesiology 24:111

Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77:1058–1064

Baumgaertner MR, Solberg BD (1997) Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br 79:969–971

Bonamo JJ, Accettola AB (1982) Treatment of intertrochanteric fractures with a sliding nail-plate. J Trauma 22:205–215

Cleveland M, Bosworth DM, Thompson FR, Wilson HJ Jr, Ishizuka T (1959) A ten-year analysis of intertrochanteric fractures of the femur. J Bone Joint Surg Am 41:1399–1408

Davis TR, Sher JL, Horsman A, Simpson M, Porter BB, Checketts RG (1990) Intertrochanteric femoral fractures: mechanical failures after internal fixation. J Bone Joint Surg Br 72:26–31

Evans EM (1951) Trochanteric fractures: a review of 110 cases treated by nail-plate fixation. J Bone Joint Surg Br 33:192–204

Garden RS (1961) Low-angle fixation in fractures of the femoral neck. J Bone Joint Surg Br 43:647–663

Kaufer H, Mattews LS, Sonstegard D (1974) Stable fixation of intertrochanteric fracture. A biomechanical evaluation. J Bone Joint Surg Am 56:899–907

Kyle RF (1994) Fractures of the proximal part of the femur. J Bone Joint Surg Am 76:924–950

Kyle RF, Gustilo RB, Premer RF (1976) Analysis of six hundred and twenty-two intertrochanteric hip fractures. A retrospective and prospective study. J Bone Joint Surg Am 61:216–221

Geller JA, Saifi C, Morrison TA, Macaulay W (2009) Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures. Int Orthop. doi: 10.1007/s00264-009-0837-7

Larsson S, Friberg S, Hansson LI (1990) Trochanteric fractures. Influence of reduction and implant position on impaction and complications. Clin Orthop 259:130–139

Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Strømsøe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures. A comparative study with Gamma nail and compression hip screw. J Orthop Trauma 12:241–248

Mainds CC, Newman RJ (1989) Implant failures in patients with proximal fractures of the femur treated with a sliding screw device. Injury 20:98–100

Liu M, Yang Z, Pei F, Huang F, Chen S, Xiang Z (2009) A meta-analysis of the Gamma nail and dynamic hip screw in treating peritrochanteric fractures. Int Orthop. doi: 10.1007/s00264-009-0783-4 , April Online Published

Parker MJ (1992) Cutting-out of the dynamic hip screw related to its position. J Bone Joint Surg Br 74:625

Nordin S, Zulkifli O, Faisham WI (2001) Mechanical failure of dynamic Hip Screw (DHS) fixation in intertrochanteric fracture of the femur. Med J Malaysia 56:12–17

Parker MJ, Handoll HH (2008) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev 16(3):CD000093

Parker MJ (1993) Valgus reduction of trochanteric fractures. Injury 24:313–316

Pervez H, Parker MJ, Vowler S (2004) Prediction of fixation failure after sliding hip screw fixation. Injury 35:994–998

Gundle R, Gargan MF, Simpson AH (1995) How to minimize failure of fixation of unstable intertrochanteric fractures. Injury 26:611–614

Saarenpää I, Heikkinen T, Ristiniemi J, Hyvönen P, Leppilahti J, Jalovaara P (2009) Functional comparison of the dynamic hip screw and the Gamma locking nail in trochanteric hip fractures: a matched-pair study of 268 patients. Int Orthop 33:255–260

Simpson AH, Varty K, Dodd CAF (1989) Sliding hip screw: modes of failure. Injury 20:227–231

Wu CC, Shih CH, Lee MY, MS TCL (1996) Biomechanical analysis of location of lag screw of a dynamic hip screw in treatment of unstable intertrochanteric fracture. J Trauma 41:699–702