Remote Absolute Roll-Angle Measurement in Range of 180° Based on Polarization Modulation

Springer Science and Business Media LLC - Tập 3 - Trang 228-235 - 2020
Xiuguo Chen1, Jinbao Liao1, Honggang Gu1, Chuanwei Zhang1, Hao Jiang1, Shiyuan Liu1
1State Key Lab of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan, China

Tóm tắt

Remote measurement of object orientation is often required in many applications. Out of the six degrees of freedom (DoF) that determine object orientation in space, the roll angle is the most difficult to measure using optical methods. In this letter, we propose a remote Stokes roll-angle sensor that measures roll angles from the detected Stokes vectors of modulated polarized light retroreflected from a sensing unit comprised simply of a retarder and a planar reflection mirror. Experimental results have shown that the proposed sensor can realize absolute roll angle measurement in an unprecedented range of 180° with a maximum absolute error of less than 0.25° and a measurement resolution of better than 0.01°. The proposed sensor adopts a coaxial design and takes the advantages of compactness, simplicity and low cost, and moreover, can be further expanded to a three-DoF angle sensor due to the sensitivity of the sensing unit to other two kinds of angles (pitch and yaw).

Tài liệu tham khảo

Tanner E, Granade S, Whitehead CA (2003) Autonomous rendezvous and docking sensor suite. Proc SPIE 5086:329–339 Arp TB, Hagedorn CA, Schlamminger S, Gundlach JH (2013) A reference-beam autocollimator with nanoradian sensitivity from mHz to kHz and dynamic range of 107. Rev Sci Instrum 84(9):095007 Billard A, Kragic D (2019) Trends and challenges in robot manipulation. Science 364:eaat8414 Kim JA, Kim JW, Kang CS, Jin J, Eom TB (2012) An optical absolute position measurement method using a phase-encoded single-track binary code. Rev Sci Instrum 83(11):115115 Gao W, Kim SW, Bosse H, Haitjema H, Chen YL, Lu XD, Knapp W, Weckenmann A, Estler WT, Kunzmann H (2015) Measurement technologies for precision engineering. CIRP Ann Manuf Technol 64:773–796 Liu Z, Lin D, Jiang H, Yin C (2003) Roll angle interferometer by means of wave plates. Sens Actuators A Phys 104(2):127–131 Qi J, Wang Z, Huang J, Gao J (2018) Resolution-enhanced heterodyne laser interferometer with differential configuration for roll angle measurement. Opt Express 26(8):9634–9644 Zhai Y, Feng Q, Zhang B (2012) A simple roll measurement method based on a rectangular-prism. Opt Laser Technol 44(4):839–843 Ploster E, Arnon S (2014) Statistics of remote roll angle measurement. Appl Opt 53(11):2437–2440 Li S, Yang C, Zhang E, Jin G (2005) Compact optical roll-angle sensor with large measurement range and high sensitivity. Opt Lett 30(3):242–244 Gillmer SR, Yu X, Wang C, Ellis JD (2015) Robust high-dynamic-range optical roll sensing. Opt Lett 40(11):2497–2500 Chen X, Liao J, Gu H, Shi Y, Jiang H, Liu S (2019) Proof of principle of an optical Stokes absolute roll-angle sensor with ultra-large measuring range. Sens Actuators A Phys 291:144–149 Tan Y, Chen C, Chen X, Du W, Gu H, Liu S (2018) Development of a tomographic Mueller-matrix scatterometer for nanostructure metrology. Rev Sci Instrum 89(7):073702 Goldstein DH (2011) Polarized light, 3rd edn. CRC Press, New York Chap 16 Chen X, Tao Z, Chen C, Wang C, Wang L, Jiang H, Fan D, Ekinci Y, Liu S (2018) All-dielectric metasurface-based roll-angle sensor. Sens Actuators A Phys 279:509–517 Zhang S, Jiang H, Gu H, Chen X, Liu S (2020) Attitude metrology based on field-of-view effect of birefringence using high-speed polarimetry. Opt Lett 45(7):2074–2077 Press WH, Teukolsky SA, Vetterling WT, Flannery BP (2007) Numerical recipes: the art of scientific computing, 3rd edn. Cambridge University Press, Cambridge Lawall J, Kessler E (2000) Michelson interferometry with 10 pm accuracy. Rev Sci Instrum 71(7):2669–2676 Magaña-Loaiza OS, Mirhosseini M, Rodenburg B, Boyd RW (2014) Amplification of angular rotations using weak measurements. Phys Rev Lett 112(20):200401 Harris J, Boyd RW, Lundeen JS (2017) Weak value amplification can outperform conventional measurement in the presence of detector saturation. Phys Rev Lett 118(7):070802 Gillmer SR, Martínez-Rincón J, Ellis JD (2018) Anomalous vibration suppression in a weak-value-emulated heterodyne roll interferometer. Opt Express 26(22):29311–29318 He D, Xie B, Feng S (2016) Null polarimetry near shot noise limit at 1 Hz. Rev Sci Instrum 87(4):043012