Physical-chemical oil tests, monitoring and diagnostics of oil-filled transformers
Proceedings of 2002 IEEE 14th International Conference on Dielectric Liquids. ICDL 2002 (Cat. No.02CH37319) - Trang 242-247
Tóm tắt
This paper presents physical-chemical testing methods as used today worldwide and at the Institute Chemistry Department. Investigation results obtained by means of various physical-chemical tests of transformer oil samples provide not only the liquid dielectrics quality; they also enable diagnosis of the current operational capability, estimating reliability and assessment of the residual technical lifetime of power, instrument and furnace transformers. Findings based on experimental research and experience of the Institute's Chemistry Department in the furanic-in-oil HPLC analysis of transformers in service are presented. They enable diagnosis of the degradation degree of paper insulation in oil-filled paper-insulated HV transformers. This paper advises HV transformer owners or supervisors which oil tests should be made to get the right or expected information about transformers in their different lifetime situations. Various Institute programs in compliance with which transformer preventive diagnostics are being pursued are discussed. The described efforts laid in practicing regular preventive diagnostics have enabled appropriate transformer maintenance whenever practicable. This means that transformers are serviced in time, efficiently and at the minimum cost, thus providing the basis for their reliable long-term operation.
Từ khóa
#Petroleum #Monitoring #Transformers #Chemistry #Life testing #Oil insulation #Dielectric liquids #Life estimation #Lifetime estimation #InstrumentsTài liệu tham khảo
de pablo, 1997, Furanic Compounds Analysis: A Tool for Predictive Maintenance of Oil-Filled Electrical Equipment, Electra No 175, 9
kon?an-gradnik, 1996, A Study of Ageing of Paper Insulation in Transformers with Liquid Chromatography, Elektroinštitut Milan Vidmar
varl, 1997, A Study of Effect of Transformer Oil Quality on Paper Insulation Degradation Elektroinštitut Milan Vidmar
kon?an-gradnik, 1998, A Studyof Influences on the Relationship Between Furans Dissolved in Oil and Ageing of Paper of Transformer Elektroinštitut Milan Vidmar, 48
de pablo, 0, Furanic compounds analysis as a tool for diagnostic and mainteance of oil-paper insulation system, CIGRE Symposium on Diagnostic and Maintenance Techniques, 110
griffin, 1996, Experience in testing for furanic compounds in the U.S.A, Presentation to CIGRE WG 15 01
myers, 0, Field studies of Furan ormation in Transformer Fluids as un Indicator of Damage to Paper Insulation, Minutes of the Fifty-Ninth Annual International Conference of Doble Clients
mulej, 0, Ouality assurance system of transformer diagnostics laboratories, ICDL 2002
1992, IEC 60567 Guide for the sampling of gases and of oil from oil-filled electrical equipment and for the analysis of free and dissolved gases
1999, IEC60599 Interpretation of the analysis of gases in transformers and other oil-filled electrical equipment in service
kon?an-gradnik, 0, Chromatographic Transformer Diagnostics for the conf-date 2000, Third conference of Slovene energy experts Nova Gorica Slovene committee of the international conference for large electrical energy systems, 15/9
mollmann, 1999, New Guidelines for Interpretation of Dissolved Gas Analysis in Oil-Filled Transformers, Electra No 186, 31
varl, 0, On-line diagnostic of Oil Filled Transformers ICDL 2002 Provisional Subject 4 Paper Number 45
varl, 2001, Study of correlations of on-line diagnostic methods on power transformers, 44
1989, IEC 60422 Supervision and maintenance guide for mineral insulating oils in electrical equipment
1982, IEC 60296 Specifications for unused Mineral Insulating Oils for Transformers and Switchgear
1993, Mineral insulating oils-Methods for the determination of 2-furfural and related compounds