No difference between venous and capillary blood sampling and the Minimed continuous glucose monitoring system for determining the blood glucose response to food

Nutrition Research - Tập 26 - Trang 403-408 - 2006
Alison J. Wallace1, Jinny A. Willis2, John A. Monro3, Chris M. Frampton4, Duncan I. Hedderley3, Russell S. Scott2
1New Zealand Institute for Crop and Food Research Limited, Private Bag 4704, Christchurch, New Zealand
2Lipid and Diabetes Research Group, Private Bag 4710, Christchurch, New Zealand
3New Zealand Institute for Crop and Food Research Limited, Private Bag 11600, Palmerston North, New Zealand
4Christchurch School of Medicine, Private Bag 4345, Christchurch, New Zealand

Tài liệu tham khảo

Wolever, 1991, The glycemic index: methodology and clinical implications, Am J Clin Nutr, 54, 846, 10.1093/ajcn/54.5.846 Monro, 2000, Concurrent management of postprandial glycaemia and nutrient intake using glycaemic glucose equivalents, food composition data and computer-assisted meal design, Asia Pac J Clin Nutr, 9, 67, 10.1046/j.1440-6047.2000.00146.x Monro, 1997, Glycaemic index and available carbohydrates in exchanges of New Zealand foods, Proc Nutr Soc NZ, 22, 241 Monro, 1999, Available carbohydrate data and glycemic index combined in new data sets for managing glycaemia and diabetes, J Food Compos Anal, 12, 71, 10.1006/jfca.1998.0806 Monro, 2003, Food data for glycaemic control, Food Sci Central, 1 Salmeron, 1997, Dietary fibre, glycaemic load, and risk of NIDDM in men, Diabetes Care, 20, 545, 10.2337/diacare.20.4.545 Wolever, 2003, Determination of the glycaemic index of foods: interlaboratory study, Eur J Clin Nutr, 57, 475, 10.1038/sj.ejcn.1601551 Steil, 2000, Accurate determination of plasma glucose during hyper- and hypoglycemia with a subcutaneous glucose sensor, Diabetes, 49, 510 Guerci, 2003, Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs, Diabetes Care, 26, 582, 10.2337/diacare.26.3.582 Gross, 2000, Efficacy and reliability of the continuous glucose monitoring system, Diabetes Technol Ther, 2, S19, 10.1089/15209150050214087 Gross, 2000, Performance evaluation of the Minimed continuous glucose monitoring system during patient home use, Diabetes Technol Ther, 2, 49, 10.1089/152091500316737 Rebrin, 1999, Delay correction and smoothing of subcutaneous glucose sensor measurements, Diabetes, 48, 362 Boyne, 2003, Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor, Diabetes, 52, 2790, 10.2337/diabetes.52.11.2790 Hales, 1963, Effects of low-carbohydrate diet and diabetes mellitus on plasma concentrations of glucose, non-esterified fatty acid and insulin during oral glucose tolerance tests, Lancet, 1, 790, 10.1016/S0140-6736(63)91501-0 Robertson, 2002, Extended effect of evening meal carbohydrate/fat ratio on fasting and postprandial substrate metabolism, Am J Clin Nutr, 75, 505, 10.1093/ajcn/75.3.505 Malkova, 2000, Prior exercise and postprandial substrate extraction across the human leg, Am J Physiol Endocrinol Metab, 279, E1020, 10.1152/ajpendo.2000.279.5.E1020 Siler, 1998, The inhibition of gluconeogenesis following alcohol in humans, Am J Physiol, 275, E897 Klein, 1993, Progressive alterations in lipid and glucose metabolism during short-term fasting in young adult men, Am J Physiol, 265, E801 Wolever, 1986, The use of the glycemic index in predicting the blood glucose response to mixed meals, Am J Clin Nutr, 43, 167, 10.1093/ajcn/43.1.167 Wolever, 1996, Source and amount of carbohydrate affect postprandial glucose and insulin in normal subjects, J Nutr, 126, 2798 Lee, 1992, Diurnal variation in glucose tolerance, Diabetes, 41, 750, 10.2337/diab.41.6.750 Jarrett, 1969, Diurnal variation of oral glucose tolerance: a possible pointer to the evolution of diabetes mellitus, BMJ, 2, 341, 10.1136/bmj.2.5653.341 Carroll, 1973, Diurnal variation in glucose tolerance and in insulin secretion in man, Diabetes, 22, 333, 10.2337/diab.22.5.333 Wolever, 1995, Physiological modulation of plasma free fatty acid concentration by diet. Metabolic implications in nondiabetic subjects, Diabetes Care, 18, 962, 10.2337/diacare.18.7.962 Wolever, 1988, Second-meal effect: low glycemic-index foods eaten at dinner improve subsequent breakfast glycemic response, Am J Clin Nutr, 48, 1041, 10.1093/ajcn/48.4.1041 Trinick, 1986, Effect of guar on second-meal glucose tolerance in normal man, Clin Science (London), 71, 49, 10.1042/cs0710049 Jenkins, 1982, Slow release dietary carbohydrate improves second meal tolerance, Am J Clin Nutr, 35, 1339, 10.1093/ajcn/35.6.1339